Sit-to-stand Timing Measurements Using Pressure Sensitive Technology

被引:0
|
作者
Veledar, I. [1 ]
Arcelus, A. [1 ]
Goubran, R. [1 ]
Knoefel, F. [3 ]
Sveistrup, H. [2 ]
Bilodeau, M. [2 ]
机构
[1] Carleton Univ, Dept Syst & Comp Engn, Ottawa, ON K1S 5B6, Canada
[2] Univ Ottawa, Sch Rehabil Sci, Ottawa, ON K1N 6N5, Canada
[3] Elisabeth Bruyere Res Inst, Bruyere Continuing Care, Ottawa, ON K1N 6N5, Canada
来源
2010 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE I2MTC 2010, PROCEEDINGS | 2010年
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
sit-to-stand timing measurement; pressure sensitive array; patient monitoring; smart homes; SENSOR; ARRAY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Measuring and analyzing the sit-to-stand movement performed by an individual when rising from their bed can be used to document health and mobility. This paper investigates measuring sit-to-stand timing from young healthy subjects using non-invasive pressure sensitive array technology. First, it describes the pressure sensitive array, the experiment setup and data collection process. Next, three methods for measuring sit-tostand timing are examined. These include a method based on the combination of bed and foot pressure, an image-based method and a pressure signal-based method. Challenges, limitations and results are shown for each using data collected from 10 young healthy subjects. The pressure signal-based method measures the sit-to-stand time more effectively when comparing to video data. The further development of this method is then presented; this includes analyzing the pressure signal to detect phases that make up the sit-to-stand movement and a sample result for one young healthy subject is presented.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Stress Measurements on the Articular Cartilage Surface Using Fiber Optic Technology and In-Vivo Gait Kinematics
    Vakiel, Paris
    Shekarforoush, Mehdi
    Dennison, Christopher R.
    Scott, Michael
    Frank, Cyril B.
    Hart, David A.
    Shrive, Nigel G.
    ANNALS OF BIOMEDICAL ENGINEERING, 2020, 48 (12) : 2836 - 2845
  • [42] Using Continuous Motion Monitoring Technology to Determine Patient's Risk for Development of Pressure Ulcers
    Zimlichman, Eyal
    Shinar, Zvika
    Rozenblum, Ronen
    Levkovich, Shiraz
    Skiano, Sarit
    Szyper-Kravitz, Martine
    Altman, Arie
    Amital, Howard
    Shoenfeld, Yehuda
    JOURNAL OF PATIENT SAFETY, 2011, 7 (04) : 181 - 184
  • [43] Poly-(fluoro isopropyl butyl methacrylate)/graphene-based sensitive oxygen nanocomposite: Electrical measurements and chemical interaction in variable pressure
    de Souza, Camila Brito
    Martins Duque, Maria Eduarda
    Ferreira, Anderson
    de Arruda, Milena Nakagawa
    de Lima Almeida, Dalva Alves
    Fontana, Luis Cesar
    Miyakawa, Walter
    Goncalves, Emerson Sarmento
    MATERIALS TODAY COMMUNICATIONS, 2020, 25
  • [44] Pressure and distance measurements under temperature interference by using impedance change of spiral conductive polymer composite
    Wang, Luheng
    Hu, Zhineng
    Shui, Wenju
    Wu, Fei
    MEASUREMENT, 2025, 241
  • [45] Highly transparent, stretchable, and conformable silicone -based strain/pressure-sensitive capacitor using adhesive polydimethylsiloxane
    Kim, Sun Ok
    Han, Chul Jong
    Lee, Cheul-Ro
    Kim, Jong-Woong
    JOURNAL OF ALLOYS AND COMPOUNDS, 2020, 841
  • [46] Highly-sensitive Measurements of Changes in Density and Refractive Index of Air using Fiber Laser Polarization Mode Beating Techniques
    Rosales-Garcia, Andrea
    Morse, T. F.
    Hernandez-Cordero, Juan
    2010 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO) AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (QELS), 2010,
  • [47] Conformable and ionic textiles using sheath-core carbon nanotube microyarns for highly sensitive and reliable pressure sensors
    Kim, So Young
    Jee, Eunsong
    Kim, Joo Sung
    Kim, Do Hwan
    RSC ADVANCES, 2017, 7 (38): : 23820 - 23826
  • [48] Dynamic Measurements of 1000 Microstrains Using Chirped-Pulse Phase-Sensitive Optical Time-Domain Reflectometry
    Bhatta, Hari Datta
    Costa, Luis
    Garcia-Ruiz, Andres
    Fernandez-Ruiz, Maria R.
    Martins, Hugo F.
    Tur, Moshe
    Gonzalez-Herraez, Miguel
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2019, 37 (18) : 4888 - 4895
  • [49] Fabrication of highly sensitive field emission based pressure sensor, using CNTs grown on micro-machined substrate
    Doostani, Narges
    Darbari, Sara
    Mohajerzadeh, S.
    Moravvej-Farshi, M. K.
    SENSORS AND ACTUATORS A-PHYSICAL, 2013, 201 : 310 - 315
  • [50] Robust Data-Driven Leak Localization in Water Distribution Networks Using Pressure Measurements and Topological Information
    Alves, Debora
    Blesa, Joaquim
    Duviella, Eric
    Rajaoarisoa, Lala
    SENSORS, 2021, 21 (22)