Sit-to-stand Timing Measurements Using Pressure Sensitive Technology

被引:0
|
作者
Veledar, I. [1 ]
Arcelus, A. [1 ]
Goubran, R. [1 ]
Knoefel, F. [3 ]
Sveistrup, H. [2 ]
Bilodeau, M. [2 ]
机构
[1] Carleton Univ, Dept Syst & Comp Engn, Ottawa, ON K1S 5B6, Canada
[2] Univ Ottawa, Sch Rehabil Sci, Ottawa, ON K1N 6N5, Canada
[3] Elisabeth Bruyere Res Inst, Bruyere Continuing Care, Ottawa, ON K1N 6N5, Canada
来源
2010 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE I2MTC 2010, PROCEEDINGS | 2010年
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
sit-to-stand timing measurement; pressure sensitive array; patient monitoring; smart homes; SENSOR; ARRAY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Measuring and analyzing the sit-to-stand movement performed by an individual when rising from their bed can be used to document health and mobility. This paper investigates measuring sit-to-stand timing from young healthy subjects using non-invasive pressure sensitive array technology. First, it describes the pressure sensitive array, the experiment setup and data collection process. Next, three methods for measuring sit-tostand timing are examined. These include a method based on the combination of bed and foot pressure, an image-based method and a pressure signal-based method. Challenges, limitations and results are shown for each using data collected from 10 young healthy subjects. The pressure signal-based method measures the sit-to-stand time more effectively when comparing to video data. The further development of this method is then presented; this includes analyzing the pressure signal to detect phases that make up the sit-to-stand movement and a sample result for one young healthy subject is presented.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Highly sensitive sensor based on W-lightguides for pressure measurements
    Rzhavin, YI
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION III, 2003, 5144 : 796 - 800
  • [22] Temperature-corrected pressure sensitive paint measurements for aerodynamic applications
    Hradil, J
    Davis, C
    Mongey, K
    Gray, D
    Dalton, T
    McDonagh, C
    MacCraith, BD
    OPTO-IRELAND 2002: OPTICS AND PHOTONICS TECHNOLOGIES AND APPLICATIONS, PTS 1 AND 2, 2003, 4876 : 867 - 874
  • [23] Wireless Human Motion Detection with a Highly Sensitive Wearable Pressure Sensing Technology
    Yan, Jinli
    Liu, Jie
    Qu, Qing
    Chen, Xinjian
    Liu, Jian
    Nie, Baoqing
    ADVANCED MATERIALS TECHNOLOGIES, 2023, 8 (12)
  • [24] Technical method of improving overload of pressure sensitive chip based on sacrificial layer technology
    Chuai, Rongyan
    Yang, Yuxin
    Li, Xin
    Wang, Jian
    Zhang, Bing
    SENSORS AND ACTUATORS A-PHYSICAL, 2018, 279 : 593 - 600
  • [25] A flexible pressure sensitive colour changing device using plasmonic nanoparticles
    Rankin, A.
    McGarry, S.
    NANOTECHNOLOGY, 2015, 26 (07)
  • [26] Study of pressure sensitive coating using palladium octaethylporphyrin as luminescent molecule
    Cao, Xianlong
    Deng, Hongda
    Lan, Wei
    SMART MATERIALS AND INTELLIGENT SYSTEMS, PTS 1 AND 2, 2011, 143-144 : 1002 - 1006
  • [27] Deep learning for simultaneous measurements of pressure and temperature using arch resonators
    Ghommem, Mehdi
    Puzyrev, Vladimir
    Najar, Fehmi
    APPLIED MATHEMATICAL MODELLING, 2021, 93 : 728 - 744
  • [28] Early Blood Clot Detection Using Forward Scattering Light Measurements Is Not Superior to Delta Pressure Measurements
    Fischbach, Anna
    Lamberti, Michael
    Simons, Julia Alexandra
    Wrede, Erik
    Theissen, Alexander
    Winnersbach, Patrick
    Rossaint, Rolf
    Stollenwerk, Andre
    Bleilevens, Christian
    BIOSENSORS-BASEL, 2023, 13 (12):
  • [29] Distributed temperature measurements using optical fibre technology in an underground mine environment
    Aminossadati, Sailed M.
    Mohammed, Nayeemuddin M.
    Shemshad, Javad
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2010, 25 (03) : 220 - 229
  • [30] Sensors and technologies for in situ dissolved methane measurements and their evaluation using Technology Readiness Levels
    Boulart, C.
    Connelly, D. P.
    Mowlem, M. C.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2010, 29 (02) : 186 - 195