Optimized Density-Weighted Imaging for Dynamic Contrast-Enhanced 3D-MR Mammography

被引:0
|
作者
Gutberlet, Marcel [1 ,2 ]
Roth, Anne [1 ]
Hahn, Dietbert [1 ]
Koestler, Herbert [1 ]
机构
[1] Hannover Med Sch, Inst Radiol, D-30165 Hannover, Germany
[2] Univ Wurzburg, Inst Rontgendiagnost, Wurzburg, Germany
关键词
density weighting; spatial response function; signal-to-noise ratio; phase-constrained; 3D imaging; MR mammography; HUMAN HEART; SENSITIVITY; RECONSTRUCTION; ACQUISITION; RESOLUTION; GRAPPA; MRI; SENSE; WATER;
D O I
10.1002/jmri.22443
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To increase the spatial coverage and to reduce slice crosstalk combined with an optimal signal-to-noise ratio (SNR) in 3D dynamic contrast-enhanced (DCE) magnetic resonance (MR) mammography. Materials and Methods: Asymmetric sampling schemes and a new reconstruction strategy based on virtual coils are presented for density-weighted (DW) 3D imaging. Additionally, for MR mammography an alternating DW (ADW) sampling along the k(y) direction shifts the under-sampling artifacts out of the signal reception region. Virtual coils for effective DW (VIDED) imaging suppresses the abasing in undersampled DW imaging. VIDED and ADW were compared to the conventional Cartesian imaging in phantom and in vivo MR mammography studies. Results: The slice crosstalk was significantly reduced by VIDED and compared to Cartesian imaging the SNR increased by 16%. Additionally, VIDED and ADW provided a substantially increased field of view (FOV) in the slice direction and allowed the spatial resolution to be improved (up to 60% for ADW and 30% for VIDED) without lengthening the scan time. Conclusion: VIDED and ADW improve the image quality in 3D DCE MR mammography by enhancing the spatial resolution, reducing the slice crosstalk at nearly optimal SNR, and increasing the FOV in the slice direction. For VIDED no lengthening of the scan time or usage of multi-channel receiver coils is necessary. Key Words: density weighting; spatial response function; signal-to-noise ratio; phase-constrained; 3D imaging; MR mammography
引用
收藏
页码:328 / 339
页数:12
相关论文
共 50 条
  • [21] Improved cardiac sodium MR imaging by density-weighted phase-encoding
    Greiser, A
    Haase, A
    von Kienlin, M
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (01) : 78 - 81
  • [22] Application of Direct Virtual Coil to Dynamic Contrast-Enhanced MRI and MR Angiography with Data-Driven Parallel Imaging
    Wang, Kang
    Beatty, Philip J.
    Nagle, Scott K.
    Reeder, Scott B.
    Holmes, James H.
    Rahimi, Mahdi S.
    Bell, Laura C.
    Korosec, Frank R.
    Brittain, Jean H.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (02) : 783 - 789
  • [23] Optimized flow compensation for contrast-enhanced T1-weighted Wave-CAIPI 3D MPRAGE imaging of the brain
    Tabari, Azadeh
    Lang, Min
    Awan, Komal
    Liu, Wei
    Clifford, Bryan
    Lo, Wei-Ching
    Splitthoff, Daniel Nicolas
    Cauley, Stephen
    Rapalino, Otto
    Schaefer, Pamela
    Huang, Susie Y.
    Conklin, John
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2023, 7 (01)
  • [24] The ductal carcinoma in situ in contrast enhanced dynamic MR mammography
    Fischer, U
    Westerhof, JP
    Brinck, U
    Korabiowska, M
    Schauer, A
    Grabbe, E
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1996, 164 (04): : 290 - 294
  • [25] Localized nasopharyngeal amyloidosis with remarkable early enhancement on dynamic contrast-enhanced MR imaging
    Utaroh Motosugi
    Tomoaki Ichikawa
    Tsutomu Araki
    Syuuichiro Endo
    Keisuke Masuyama
    Tadao Nakazawa
    European Radiology, 2007, 17 : 852 - 853
  • [26] Localized nasopharyngeal amyloidosis with remarkable early enhancement on dynamic contrast-enhanced MR imaging
    Motosugi, Utaroh
    Ichikawa, Tomoaki
    Araki, Tsutomu
    Endo, Syuuichiro
    Masuyama, Keisuke
    Nakazawa, Tadao
    EUROPEAN RADIOLOGY, 2007, 17 (03) : 852 - 853
  • [27] Contrast-enhanced and unenhanced diffusion-weighted imaging of the breast at 3 T
    Fanariotis, M.
    Tsougos, I
    Vlychou, M.
    Fezoulidis, I
    Vassiou, K.
    CLINICAL RADIOLOGY, 2018, 73 (11) : 928 - 935
  • [28] Application of FLASH-3D dynamic contrast-enhanced imaging for diagnosis of endometrial carcinoma
    Du, Lixin
    Li, Xiaohu
    Qiu, Xixiong
    Liu, Xiaolei
    Wang, Yuli
    Yu, Yongqiang
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1066):
  • [29] Dynamic contrast-enhanced 3-T MR imaging in cervical cancer before and after concurrent chemoradiotherapy
    Kim, Jae-Hun
    Kim, Chan Kyo
    Park, Byung Kwan
    Park, Sung Yoon
    Huh, Seung Jae
    Kim, Bohyun
    EUROPEAN RADIOLOGY, 2012, 22 (11) : 2533 - 2539
  • [30] Dynamic contrast-enhanced 3-T MR imaging in cervical cancer before and after concurrent chemoradiotherapy
    Jae-Hun Kim
    Chan Kyo Kim
    Byung Kwan Park
    Sung Yoon Park
    Seung Jae Huh
    Bohyun Kim