Intravascular confocal photoacoustic endoscope with dual-element ultrasonic transducer

被引:58
|
作者
Ji, Xuanrong [1 ,2 ]
Xiong, Kedi [1 ,2 ]
Yang, Sihua
Xing, Da [1 ,2 ]
机构
[1] S China Normal Univ, Coll Biophoton, MOE Key Lab Laser Life Sci, Guangzhou 510631, Guangdong, Peoples R China
[2] S China Normal Univ, Coll Biophoton, Inst Laser Life Sci, Guangzhou 510631, Guangdong, Peoples R China
来源
OPTICS EXPRESS | 2015年 / 23卷 / 07期
基金
国家高技术研究发展计划(863计划); 中国国家自然科学基金;
关键词
IN-VIVO; MICROSCOPY; TOMOGRAPHY; ATHEROSCLEROSIS; PLAQUES; ORGANS; ARRAY;
D O I
10.1364/OE.23.009130
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We have developed an intravascular confocal photoacoustic (PA) endoscope with symmetrically aligned dual-element ultrasonic transducers. By combining focused laser excitation and focused acoustic collection, the intravascular confocal PA endoscope is capable of realizing resolution enhanced intravascular PA imaging with improved signal-to-noise ratio (SNR) to ameliorate the resolution reduction caused by laser scattering with increasing tissue depth. The detection sensitivity of the endoscope is improved by 5 dB compared with that of single transducer endoscope, and the transverse resolution of the system can up to 13 mu m. Intravascular PA tomography of a normal vessel and an atherosclerotic vessel have been performed to demonstrate the imaging ability of the system. This intravascular confocal PA endoscope with an outer diameter of 1.2 mm supports potential for clinical applications in intravascular plaque imaging and subsequent diagnosis. (C) 2015 Optical Society of America
引用
收藏
页码:9130 / 9136
页数:7
相关论文
共 50 条
  • [21] LATERAL RESOLUTION OF A BROAD-BAND DUAL ELEMENT ULTRASONIC TRANSDUCER
    JETHWA, CP
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1974, SU21 (01): : 64 - 64
  • [22] A Dual-Element VNA Electronic Calibration in CMOS
    Chien, Jun-Chau
    Arbabian, Amin
    Niknejad, Ali M.
    2018 IEEE 18TH TOPICAL MEETING ON SILICON MONOLITHIC INTEGRATED CIRCUITS IN RF SYSTEMS (SIRF), 2018, : 71 - 74
  • [23] AN UNSHIELDED HORIZONTAL DUAL-ELEMENT MR SENSOR
    JONES, RE
    GUZMAN, JI
    MOUNTFIELD, KR
    KRYDER, MH
    IEEE TRANSACTIONS ON MAGNETICS, 1991, 27 (06) : 4687 - 4689
  • [24] Photoacoustic and ultrasonic coimage with a linear transducer array
    Zeng, YG
    Xing, D
    Wang, Y
    Yin, BZ
    Chen, Q
    OPTICS LETTERS, 2004, 29 (15) : 1760 - 1762
  • [25] UNSTEADY AERODYNAMIC CHARACTERISTICS OF A DUAL-ELEMENT AIRFOIL
    TUNCER, IH
    SANKAR, LN
    JOURNAL OF AIRCRAFT, 1994, 31 (03): : 531 - 537
  • [26] Photoacoustic imaging: Consideration of bandwidth of ultrasonic transducer
    Tan, Y
    Xing, D
    Wang, Y
    Gu, HM
    Yang, DW
    Qun, C
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2005, 2005, 5697 : 330 - 336
  • [27] Influence of bandwidth of ultrasonic transducer on photoacoustic imaging
    Tan, Yi
    Xing, Da
    Wang, Yi
    Zeng, Yaguang
    Yin, Bangzheng
    Guangxue Xuebao/Acta Optica Sinica, 2005, 25 (01): : 40 - 44
  • [28] The clinical study of a new ultrasonic endoscope with a hyperband transducer
    Abe, T
    Ishihara, Y
    Otake, Y
    Kakemura, T
    Sakai, Y
    GASTROINTESTINAL ENDOSCOPY, 2002, 56 (04) : S136 - S136
  • [29] Unsteady aerodynamic characteristics of a dual-element airfoil
    Tuncer, Ismail H., 1600, Publ by AIAA, Washington, DC, United States (31):
  • [30] Multifocal photoacoustic microscopy using a single-element ultrasonic transducer through an ergodic relay
    Li, Yang
    Wong, Terence T. W.
    Shi, Junhui
    Hsu, Hsun-Chia
    Wang, Lihong V.
    LIGHT-SCIENCE & APPLICATIONS, 2020, 9 (01)