Defect-dominated fatigue behavior in type 630 stainless steel fabricated by selective laser melting

被引:72
作者
Akita, Masayuki [1 ]
Uematsu, Yoshihiko [2 ]
Kakiuchi, Toshifumi [2 ]
Nakajima, Masaki [3 ]
Kawaguchi, Ryosei [4 ]
机构
[1] Gifu Univ, Fac Engn, 1-1 Yanagido, Gifu 5011193, Japan
[2] Gifu Univ, Dept Mech Engn, Gifu 5011193, Japan
[3] Toyota Coll, Natl Inst Technol, 2-1 Eisei Cho, Toyota 4718525, Japan
[4] Gifu Univ, Grad Sch Engn, Mech & Syst Engn Div, 1-1 Yanagido, Gifu 5011193, Japan
来源
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING | 2016年 / 666卷
关键词
Fatigue; Selective laser melting; Martensitic stainless steel; Microstructure; Crack initiation; Crack growth; CRACK GROWTH-BEHAVIOR; MECHANICAL-PROPERTIES; HEAT-TREATMENT; ALLOY; MICROSTRUCTURE; TI-6AL-4V; TECHNOLOGY; STRENGTH; POROSITY; PARTS;
D O I
10.1016/j.msea.2016.04.042
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Fatigue behavior of type 630 (17-4 pH) stainless steel specimens fabricated by selective laser melting (SLM) was studied. The results obtained were compared with those of the conventionally-melted (CM) type 630. In the microstructure of SLM type 630, martensite-poor and ferrite-rich areas were recognized, while in the CM type 630, acicular martensite uniformly distributed in a matrix. Relatively high temperature was held due to the additive lamination of melted powder during SLM process, which prevented full-martensite structure formation. In the SLM-quenched type 630, the microstructure consisted of acicular martensite due to the post heat treatment at 1050 degrees C followed by water quenching. The hardness was the highest in the CM type 630, and followed by SLM-quenched and SLM type 630 in decreasing order. The microstructural observation revealed that some defects (< 50 gm) distributed in the SLM and SLM-quenched type 630, which were formed during additive lamination of melted powder. Rotating bending fatigue tests were performed at a frequency of 57 Hz in laboratory air. The SLM and SLM-quenched type 630 exhibited much lower fatigue strengths compared to the CM one. One of the reasons of lower fatigue strengths in the SLM and SLM-quenched type 630 could be attributed to their lower hardness. Furthermore, fatigue cracks initiated from the defects in both SLM type 630. Consequently, fatigue crack initiated at an early stage of fatigue life in the SLM and SLM-quenched type 630, resulting in the lower fatigue strengths. However, fatigue crack growth resistances of the SLM and SLM-quenched type 630 were higher than that of the CM one due to frequent crack branching and deflection. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:19 / 26
页数:8
相关论文
共 34 条
[1]   Effect of build geometry on the β-grain structure and texture in additive manufacture of Ti-6Al-4V by selective electron beam melting [J].
Antonysamy, A. A. ;
Meyer, J. ;
Prangnell, P. B. .
MATERIALS CHARACTERIZATION, 2013, 84 :153-168
[2]   Crack propagation and fracture toughness of Ti6A14V alloy produced by selective laser melting [J].
Cain, V ;
Thijs, L. ;
Van Humbeeck, J. ;
Van Hooreweder, B. ;
Knutsen, R. .
ADDITIVE MANUFACTURING, 2015, 5 :68-76
[3]   Microstructure and mechanical behaviour of Ti-6Al-7Nb alloy produced by selective laser melting [J].
Chlebus, Edward ;
Kuznicka, Bogumila ;
Kurzynowski, Tomasz ;
Dybala, Bogdan .
MATERIALS CHARACTERIZATION, 2011, 62 (05) :488-495
[4]   Influence of defects on mechanical properties of Ti-6Al-4 V components produced by selective laser melting and electron beam melting [J].
Gong, Haijun ;
Rafi, Khalid ;
Gu, Hengfeng ;
Ram, G. D. Janaki ;
Starr, Thomas ;
Stucker, Brent .
MATERIALS & DESIGN, 2015, 86 :545-554
[5]   Effects of processing parameters on tensile properties of selective laser melted 304 stainless steel [J].
Guan, Kai ;
Wang, Zemin ;
Gao, Ming ;
Li, Xiangyou ;
Zeng, Xiaoyan .
MATERIALS & DESIGN, 2013, 50 :581-586
[6]   Reduction of micro-cracking in nickel superalloys processed by Selective Laser Melting: A fundamental alloy design approach [J].
Harrison, Neil J. ;
Todd, Iain ;
Mumtaz, Kamran .
ACTA MATERIALIA, 2015, 94 :59-68
[7]   Cellular Ti-6Al-4V structures with interconnected macro porosity for bone implants fabricated by selective electron beam melting [J].
Heinl, Peter ;
Mueller, Lenka ;
Koerner, Carolin ;
Singer, Robert F. ;
Mueller, Frank A. .
ACTA BIOMATERIALIA, 2008, 4 (05) :1536-1544
[8]   Effects of R-ratio on high-temperature fatigue crack growth behavior of a precipitation-hardening stainless steel [J].
Hsu, Kuei-Chang ;
Lin, Chih-Kuang .
INTERNATIONAL JOURNAL OF FATIGUE, 2008, 30 (12) :2147-2155
[9]   Cranial reconstruction: 3D biomodel and custom-built implant created using additive manufacturing [J].
Jardini, Andre Luiz ;
Larosa, Maria Aparecida ;
Maciel Filho, Rubens ;
de Carvalho Zavaglia, Ceclia Amelia ;
Bernardes, Luis Fernando ;
Lambert, Carlos Salles ;
Calderoni, Davi Reis ;
Kharmandayan, Paulo .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2014, 42 (08) :1877-1884
[10]   Improvement of fatigue resistance and ductility of TiAl6V4 processed by selective laser melting [J].
Kasperovich, Galina ;
Hausmann, Joachim .
JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2015, 220 :202-214