Objectives. To obtain data concerning the incidence and management of reservoir herniation in inflatable penile prosthesis surgery in a clinical investigation. Reservoir herniation after scrotal placement of inflatable penile prosthesis is an unusual complication, and a review of the published medical reports reveals only anecdotal reports and no definitive articles. Methods. A multi-item self-addressed questionnaire was mailed to the members of the Society for the Study of Impotence questioning the occurrence of reservoir migration from the prevesical space to the inguinal canal or scrotum. In addition, the database of one of us was reviewed to determine the incidence of reservoir migration in a large series of 1206 three-piece penile prostheses. Results. The response rate was 38%. A minority of respondents (28%) were familiar with the problem. Of those who had experienced this complication, the occurrence was very rare and usually appeared in the immediate postoperative period, often in association with vigorous coughing spells or vomiting. The responders also indicated that imperfect surgical technique might have been implicated in some cases. Management usually consisted of reservoir replacement or repositioning through an inguinal incision with repair of the defect. Alternatively, several surgeons used the existing scrotal incision if the patient presented in the immediate postoperative period. The incidence of reservoir herniation was 0.7%. Conclusions. Reservoir herniation is a rare complication of inflatable penile prosthesis surgery that occurs almost exclusively in penoscrotally placed prostheses. Familiarity with various approaches to the management of this complication is clinically useful to urologists performing penile prosthesis surgery. UROLOGY 57: 142-145, 2001. (C) 2001, Elsevier Science Inc.
引用
收藏
页码:142 / 145
页数:4
相关论文
共 16 条
[1]   Long-term mechanical reliability of multicomponent inflatable penile prosthesis: Comparison of device survival [J].
Dubocq, F ;
Tefilli, MV ;
Gheiler, EL ;
Li, HK ;
Dhabuwala, CB .
UROLOGY, 1998, 52 (02) :277-281
[2]  
George V K, 1995, Int J Impot Res, V7, P17
[3]   EARLY EXPERIENCE WITH THE 1ST PRE-CONNECTED 3-PIECE INFLATABLE PENILE PROSTHESIS - THE MENTOR ALPHA-1 [J].
GOLDSTEIN, I ;
BERTERO, EB ;
KAUFMAN, JM ;
WITTEN, FR ;
HUBBARD, JG ;
FITCH, WP ;
GELLER, RA ;
MCKAY, DL ;
KRANE, RJ ;
BORGES, FD ;
BABAYAN, RK ;
TUTTLE, JP ;
GRUBER, MB ;
HARIK, V ;
LEVENSON, S .
JOURNAL OF UROLOGY, 1993, 150 (06) :1814-1818
[4]   Safety and efficacy outcome of mentor alpha-1 inflatable penile prosthesis implantation for impotence treatment [J].
Goldstein, I ;
Newman, L ;
Baum, N ;
Brooks, M ;
Chaikin, L ;
Goldberg, K ;
McBride, A ;
Krane, RJ .
JOURNAL OF UROLOGY, 1997, 157 (03) :833-839
[5]   Mechanical reliability, surgical complications, and patient and partner satisfaction of the modern three-piece inflatable penile prosthesis [J].
Govier, FE ;
Gibbons, RP ;
Correa, RJ ;
Pritchett, TR ;
Kramer-Levien, D .
UROLOGY, 1998, 52 (02) :282-286
[6]  
LEWIS RW, 1995, UROL CLIN N AM, V22, P847
[7]  
LUKS FI, 1989, SURGERY, V106, P101
[9]  
Pacik D, 1995, Rozhl Chir, V74, P363
[10]   ASYNCHRONOUS EROSION OF INFLATABLE PENILE PROSTHESIS INTO SMALL AND LARGE-BOWEL [J].
SINGH, I ;
GODEC, CJ .
JOURNAL OF UROLOGY, 1992, 147 (03) :709-710