Calcium phosphate coating of nickel-titanium shape-memory alloys.: Coating procedure and adherence of leukocytes and platelets

被引:83
作者
Choi, J
Bogdanski, D
Köller, M
Esenwein, SA
Müller, D
Muhr, G
Epple, M
机构
[1] Ruhr Univ Bochum, Fac Chem, D-44780 Bochum, Germany
[2] Ruhr Univ Bochum, BG Kliniken Bergmannsheil, Dept Surg, D-44780 Bochum, Germany
关键词
Ni-Ti shape-memory alloys; leukocyte adherence; metallic implants; calcium phosphates; coating;
D O I
10.1016/S0142-9612(03)00241-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Nickel-titanium shape-memory alloys (NiTi-SMA) were coated with calcium phosphate by dipping in oversaturated calcium phosphate solution. The layer thickness (typically 5-20 mum) can be varied by choice of the immersion time. The porous nature of the layer of microcrystals makes it mechanically stable enough to withstand both the shape-memory transition upon cooling and heating and also strong bending of the material (superelastic effect). This layer may improve the biocompatibility of NiTi-SMA, particulary for osteosynthetic devices by creating a more physiological surface and by restricting a potential nickel release. The adherence of human leukocytes (peripheral blood mononuclear cells and polymorphonuclear neutrophil granulocytes) and platelets to the calcium phosphate layer was analyzed in vitro. In comparison to non-coated NiTi-SMA, leukocytes and platelets showed a significantly increased adhesion to the coated NiTi-SMA. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:3689 / 3696
页数:8
相关论文
共 58 条
  • [41] Trépanier C, 1998, J BIOMED MATER RES, V43, P433, DOI 10.1002/(SICI)1097-4636(199824)43:4<433::AID-JBM11>3.3.CO
  • [42] 2-R
  • [43] Trépanier C, 1999, J BIOMED MATER RES, V48, P165, DOI 10.1002/(SICI)1097-4636(1999)48:2<165::AID-JBM11>3.0.CO
  • [44] 2-#
  • [45] Dissolution of nickel and tissue response observed by X-ray scanning analytical microscopy
    Uo, M
    Watari, F
    Yokoyama, A
    Matsuno, H
    Kawasaki, T
    [J]. BIOMATERIALS, 1999, 20 (08) : 747 - 755
  • [46] Wataha JC, 1999, J BIOMED MATER RES, V45, P251, DOI 10.1002/(SICI)1097-4636(19990605)45:3<251::AID-JBM13>3.0.CO
  • [47] 2-5
  • [48] Wen HB, 1999, J BIOMED MATER RES, V46, P245, DOI 10.1002/(SICI)1097-4636(199908)46:2<245::AID-JBM14>3.0.CO
  • [49] 2-A
  • [50] Electrochemical and surface characterization of a nickel-titanium alloy
    Wever, DJ
    Veldhuizen, AG
    de Vries, J
    Busscher, HJ
    Uges, DRA
    van Horn, JR
    [J]. BIOMATERIALS, 1998, 19 (7-9) : 761 - 769