Punching shear strength of waffle flat slabs with opening adjacent to elongated columns

被引:8
作者
Aguiar, Amaury [1 ]
Oliveira, Denio [1 ]
Reis, Luciano [2 ]
Nzambi, Aaron [1 ]
机构
[1] Fed Univ Para, Augusto Correa 01, BR-66075110 Belem, Para, Brazil
[2] Fed Inst Sci Educ & Technol Maranhao, Sao Luis, Maranhao, Brazil
关键词
Waffle flat slab; Punching; Rectangular column opening; NLFEA;
D O I
10.1016/j.engstruct.2021.112641
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A series of 15 reinforced concrete waffle flat slabs with openings adjacent to rectangular columns was subjected to symmetrical punching tests until failure. All square slabs were 2300 mm side and 150 mm height, with different configurations for columns and openings. The largest side of the columns and openings was up to 5 and 4 times the smaller side (120 mm), respectively. The results showed that the openings really affect the behavior of the slabs, penalizing the punching shear strength, mainly of the slabs with smaller columns, and little influence of the quantity and length of the openings was observed. A non-linear finite element analysis predicted failure loads satisfactorily when compared to experimental ones, with average of 1.01 and coefficient of variation of 0.11, and statistical factors were found and improved estimates for failure loads with accuracy gain of 36% for Model Code 2010 and becoming the Brazilian code safer.
引用
收藏
页数:13
相关论文
共 31 条
[11]  
CEN European Committee for Standadization, 2004, EUR 2 DES CONCR STRU EUR 2 DES CONCR STRU
[12]  
Chaudhari S.V., 2012, INT J COMPUTER APLIC, V44, No, P14
[13]  
Damasceno LSR, 2015, S AM J STRUCT ENG, V12, P26
[14]  
DIN German Institute for Standardization, 2001, 10451 DIN 10451 DIN
[15]  
fib - International Federation for Structural Concrete, 2013, FIB MOD COD CONCR ST
[16]   Effect of Openings on Punching Shear Strength of Reinforced Concrete Slabs-Finite Element Investigation [J].
Genikomsou, Aikaterini S. ;
Polak, Maria Anna .
ACI STRUCTURAL JOURNAL, 2017, 114 (05) :1249-1261
[17]   Finite element analysis of punching shear of concrete slabs using damaged plasticity model in ABAQUS [J].
Genikomsou, Aikaterini S. ;
Polak, Maria Anna .
ENGINEERING STRUCTURES, 2015, 98 :38-48
[18]  
Genikomsou AS, 2018, ACI SPECIAL PUBLICAT, V328
[19]   Effects of openings on the punching shear strength of RC flat-plate slabs without shear reinforcement [J].
Ha, Taehun ;
Lee, Myung-Ho ;
Park, Jonghwan ;
Kim, Dae-Jin .
STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2015, 24 (15) :895-911
[20]  
Jankowiak I., 2005, 7th Conference on Composite Structures: Zielona Gora, P163