Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode

被引:147
|
作者
LoSasso, T [1 ]
Chui, CS [1 ]
Ling, CC [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
关键词
multileaf collimation; intensity modulation; dosimetry; quality assurance;
D O I
10.1118/1.1410123
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The delivery of intensity modulated radiation therapy (IMRT) using dynamic multileaf collimation (DMLC) accounts for about 40% of all treatments on eight multileaf collimator (MLC)-equipped linacs currently at the central and satellite facilities of the Memorial Sloan Kettering Cancer Center (MSKCC). These numbers have been steadily growing for the past 6 years. Treatment with IMRT has been used for a variety of cancers, including tumors of the prostate, head and neck, breast, paraspinal regions, and brain. To ensure that patients are treated in an accurate, efficient, and safe manner, we have developed a comprehensive QA program including mechanical quality assurance, which monitors known potential weaknesses in the MLC device itself, and verification of patient-specific treatments, to confirm the reliability of new software and to identify errors introduced through human interaction with individual patient's plans. This paper presents the reasoning, methodology, and results for mechanical, dosimetric, and electronic tests that are conducted at MSKCC. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:2209 / 2219
页数:11
相关论文
共 50 条
  • [21] Clinical and physical quality assurance for intensity modulated radiotherapy of prostate cancer
    Boehmer, D
    Bohsung, J
    Eichwurzel, I
    Moys, A
    Budach, V
    RADIOTHERAPY AND ONCOLOGY, 2004, 71 (03) : 319 - 325
  • [22] Impact of multileaf collimator leaf positioning accuracy on intensity modulation radiation therapy quality assurance ion chamber measurements
    Woo, MK
    Nico, A
    MEDICAL PHYSICS, 2005, 32 (05) : 1440 - 1445
  • [23] Dynamic positioning accuracy of a novel multileaf collimator for volumetric modulated arc therapy
    Nakaguchi Y.
    Ono T.
    Onizuka R.
    Maruyama M.
    Shimohigashi Y.
    Kai Y.
    Radiological Physics and Technology, 2016, 9 (1) : 121 - 126
  • [24] Multileaf collimator leaf sequencing algorithm for intensity modulated beams with multiple static segments
    Xia, P
    Verhey, LJ
    MEDICAL PHYSICS, 1998, 25 (08) : 1424 - 1434
  • [25] Changes in Patterns of Intensity-modulated Radiotherapy Verification and Quality Assurance in the UK
    Abolaban, F.
    Zaman, S.
    Cashmore, J.
    Nisbet, A.
    Clark, C. H.
    CLINICAL ONCOLOGY, 2016, 28 (08) : E28 - E34
  • [26] A multileaf collimator phantom for the quality assurance of radiation therapy planning systems and CT simulators
    McNiven, A
    Kron, T
    Van Dyk, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (03): : 994 - 1001
  • [27] Comparison of film dosimetry techniques used for quality assurance of intensity modulated radiation therapy
    Ju, Sang Gyu
    Han, Youngyih
    Kum, Oyeon
    Cheong, Kwang-Ho
    Shin, Eun Hyuk
    Shin, Jung Suk
    Kim, Jin Sung
    Ahn, Yong Chan
    MEDICAL PHYSICS, 2010, 37 (06) : 2925 - 2933
  • [28] Measurement and Monte Carlo simulation for energy- and intensity-modulated electron radiotherapy delivered by a computer-controlled electron multileaf collimator
    Jin, Lihui
    Eldib, Ahmed
    Li, Jinsheng
    Emam, Ismail
    Fan, Jiajin
    Wang, Lu
    Ma, C-M
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (01): : 177 - 186
  • [29] A quality assurance method for analyzing and verifying intensity modulated fields
    Ma, LJ
    Phaisangittisakul, N
    Yu, CX
    Sarfaraz, M
    MEDICAL PHYSICS, 2003, 30 (08) : 2082 - 2088
  • [30] Clinical performance of FractionLab in patient-specific quality assurance for intensity-modulated radiotherapy : a retrospective study
    Oh, Se An
    Kim, Sung Yeop
    Park, Jaehyeon
    Park, Jae Won
    Yea, Ji Woon
    JOURNAL OF YEUNGNAM MEDICAL SCIENCE, 2022, 39 (02): : 108 - 115