Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode

被引:147
|
作者
LoSasso, T [1 ]
Chui, CS [1 ]
Ling, CC [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
关键词
multileaf collimation; intensity modulation; dosimetry; quality assurance;
D O I
10.1118/1.1410123
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The delivery of intensity modulated radiation therapy (IMRT) using dynamic multileaf collimation (DMLC) accounts for about 40% of all treatments on eight multileaf collimator (MLC)-equipped linacs currently at the central and satellite facilities of the Memorial Sloan Kettering Cancer Center (MSKCC). These numbers have been steadily growing for the past 6 years. Treatment with IMRT has been used for a variety of cancers, including tumors of the prostate, head and neck, breast, paraspinal regions, and brain. To ensure that patients are treated in an accurate, efficient, and safe manner, we have developed a comprehensive QA program including mechanical quality assurance, which monitors known potential weaknesses in the MLC device itself, and verification of patient-specific treatments, to confirm the reliability of new software and to identify errors introduced through human interaction with individual patient's plans. This paper presents the reasoning, methodology, and results for mechanical, dosimetric, and electronic tests that are conducted at MSKCC. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:2209 / 2219
页数:11
相关论文
共 50 条
  • [1] Siemens multileaf collimator characterization and quality assurance approaches for intensity-modulated radiotherapy
    Bayouth, John E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : S93 - S97
  • [2] Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy
    LoSasso, T
    Chui, CS
    Ling, CC
    MEDICAL PHYSICS, 1998, 25 (10) : 1919 - 1927
  • [3] Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate
    Burman, C
    Chui, CS
    Kutcher, G
    Leibel, S
    Zelefsky, M
    LoSasso, T
    Spirou, S
    Wu, QW
    Yang, J
    Stein, J
    Mohan, R
    Fuks, Z
    Ling, CC
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (04): : 863 - 873
  • [4] A method for determining multileaf collimator transmission and scatter for dynamic intensity modulated radiotherapy
    Arnfield, MR
    Siebers, JV
    Kim, JO
    Wu, QW
    Keall, PJ
    Mohan, R
    MEDICAL PHYSICS, 2000, 27 (10) : 2231 - 2241
  • [5] Quality assurance for dynamic multileaf collimator modulated fields using a fast beam imaging system
    Ma, LJ
    Geis, PB
    Boyer, AL
    MEDICAL PHYSICS, 1997, 24 (08) : 1213 - 1220
  • [6] Clinical delivery of intensity modulated conformal radiotherapy for relapsed or second-primary head and neck cancer using a multileaf collimator with dynamic control
    De Neve, W
    De Gersem, W
    Derycke, S
    De Meerleer, G
    Moerman, M
    Bate, MT
    Van Duyse, B
    Vakaet, L
    De Deene, Y
    Mersseman, B
    De Wagter, C
    RADIOTHERAPY AND ONCOLOGY, 1999, 50 (03) : 301 - 314
  • [7] Characterization of a commercial multileaf collimator used for intensity modulated radiation therapy
    Low, DA
    Sohn, JW
    Klein, EE
    Markman, J
    Mutic, S
    Dempsey, JF
    MEDICAL PHYSICS, 2001, 28 (05) : 752 - 756
  • [8] Improving the resolution of dynamic intensity modulated radiation therapy delivery by reducing the multileaf collimator sampling distance
    Greer, PB
    Beckham, WA
    Ansbacher, W
    Mann, RK
    MEDICAL PHYSICS, 2003, 30 (10) : 2793 - 2803
  • [9] Independent monitor unit calculation for intensity modulated radiotherapy using the MIMIC multileaf collimator
    Chen, Z
    Xing, L
    Nath, R
    MEDICAL PHYSICS, 2002, 29 (09) : 2041 - 2051
  • [10] Quality assurance methods for intensity modulated radiotherapy
    Cakir, Aydin
    Bilge, Hatice
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2013, 28 (02): : 81 - 90