Radioluminescence of Ge-doped silica optical fibre and Al2O3:C dosimeters

被引:18
作者
Rahman, A. K. M. Mizanur [1 ,3 ]
Begum, Mahfuza [2 ,3 ]
Begum, Mahbuba [1 ]
Zubair, H. T. [3 ]
Abdul-Rashid, H. A. [3 ]
Yusoff, Z. [3 ]
Bradley, D. A. [4 ,5 ]
机构
[1] Bangladesh Atom Energy Commiss, Hlth Phys Div, Atom Energy Ctr, 4 Kazi Nazrul Islam Ave, Dhaka 1000, Bangladesh
[2] Bangladesh Atom Energy Commiss, Hlth Phys & Radioact Waste Management Unit, Inst Nucl Sci & Technol, Atom Energy Res Estab, Dhaka, Bangladesh
[3] Multimedia Univ, Fibre Opt Res Ctr, Fac Engn, Jalan Multimedia, Cyberjaya 63100, Malaysia
[4] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
[5] Sunway Univ, Inst Hlth Care Dev, Pj 46150, Malaysia
关键词
Radioluminescence; Ge-doped optical fibre; NanoDots Al2O3C; Afterglow; REAL-TIME DOSIMETRY; MEDICAL DOSIMETRY; RADIATION-DOSIMETRY; LUMINESCENCE; RADIOTHERAPY; THERAPY; SIGNAL;
D O I
10.1016/j.sna.2017.12.032
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Using an electron accelerator producing a 6 MV X-ray photon beam several experimentally observed excitation phenomena that are associated with radioluminescence (RL) have been investigated, the signal originating from a Ge-doped silica optical fibre and commercial nanoDot Al2O3:C dosimeters. Using PMMA optical communication fibres the RL signals have been guided from the beam-delivery room out to the readout instrumentation that has been located beyond the concrete maze providing effective radiation shield. Ge-doped silica fibre memory effects and afterglow (phosphorescence) were compared with that of the commercial Al2O3:C dosimeter. Immediately following RL, observation was made of the decay curves of the afterglow signal of Al2O3:C. Conversely, there was little practically observable afterglow for the Ge-doped fibre used for the majority of present investigations (the dopant concentration of this being 3.6 wt %). Among three different concentration of Ge-doped fibres that were subsequently investigated in a follow-up study, the intensity of afterglow was found to be greatest for the more highly doped concentration (7.0 wt % Ge), with progressive reduction of the effect for the Ge 4.7 wt % and Ge 3.6 wt % fibres. These observations can be compared against the much more marked RL memory effect observed using the Al2O3:C chips. Current results point to the Ge-doped silica optical fibre being a highly promising candidate for real-time RL dosimetry and sensing. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:72 / 78
页数:7
相关论文
共 32 条
[1]   Optically stimulated luminescence and its use in medical dosimetry [J].
Akselrod, M. S. ;
Botter-Jensen, L. ;
McKeever, S. W. S. .
RADIATION MEASUREMENTS, 2006, 41 :S78-S99
[2]   Thermoluminescence glow curves and deconvoluted glow peaks of Ge doped flat fibers at ultra-high doses of electron radiation [J].
Alawiah, A. ;
Bauk, S. ;
Marashdeh, M. W. ;
Ng, K. S. ;
Abdul-Rashid, H. A. ;
Yusoff, Z. ;
Gieszczyk, W. ;
Noramaliza, M. N. ;
Mahdiraji, G. A. ;
Tamchek, N. ;
Muhd-Yassin, S. Z. ;
Mat-Sharif, K. A. ;
Zulkifli, M. I. ;
Maah, M. J. ;
Omar, S. S. Che ;
Bradley, D. A. .
RADIATION PHYSICS AND CHEMISTRY, 2015, 113 :53-58
[3]  
Alloy E., 2008, MANAGING HLTH EFFECT, P20055
[4]   An algorithm for real-time dosimetry in intensity-modulated radiation therapy using the radioluminescence signal from Al2O3:C [J].
Andersen, C. E. ;
Marckmann, C. J. ;
Aznar, M. C. ;
Botter-Jensen, L. ;
Kjaer-Kristoffersen, F. ;
Medin, J. .
RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) :7-13
[5]   Fiber-coupled Luminescence Dosimetry in Therapeutic and Diagnostic Radiology [J].
Andersen, Claus E. .
CONCEPTS AND TRENDS IN MEDICAL RADIATION DOSIMETRY, 2011, 1345 :100-119
[6]   Precision of RL/OSL medical dosimetry with fiber-coupled Al2O3:C: Influence of readout delay and temperature variations [J].
Andersen, Claus E. ;
Edmund, Jens M. ;
Damkjaer, Sidsel M. S. .
RADIATION MEASUREMENTS, 2010, 45 (3-6) :653-657
[7]   High-resolution fiber-optic dosimeters for microbeam radiation therapy [J].
Archer, James ;
Li, Enbang ;
Petasecca, Marco ;
Lerch, Michael ;
Rosenfeld, Anatoly ;
Carolan, Martin .
MEDICAL PHYSICS, 2017, 44 (05) :1965-1968
[8]   In vivo absorbed dose measurements in mammography using a new real-time luminescence technique [J].
Aznar, MC ;
Hemdal, B ;
Medin, J ;
Marckmann, CJ ;
Andersen, CE ;
Botter-Jensen, L ;
Andersson, I ;
Mattsson, S .
BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (928) :328-334
[9]   The effect of different dopant concentration of tailor-made silica fibers in radiotherapy dosimetry [J].
Begum, Mahfuza ;
Rahman, A. K. M. Mizanur ;
Zubair, H. T. ;
Abdul-Rashid, H. A. ;
Yusoff, Z. ;
Begum, Mahbuba ;
Alkhorayef, M. ;
Alzimami, K. ;
Bradley, D. A. .
RADIATION PHYSICS AND CHEMISTRY, 2017, 141 :73-77
[10]   Thermoluminescence characteristics of Ge-doped optical fibers with different dimensions for radiation dosimetry [J].
Begum, Mahfuza ;
Rahman, A. K. M. Mizanur ;
Abdul-Rashid, H. A. ;
Yusoff, Z. ;
Begum, Mahbuba ;
Mat-Sharif, K. A. ;
Amin, Y. M. ;
Bradley, D. A. .
APPLIED RADIATION AND ISOTOPES, 2015, 100 :79-83