Radiofrequency ablation with a new perfused-cooled electrode using a single pump:: An experimental study in Ex vivo bovine liver

被引:6
作者
Kim, SK [1 ]
Se, JW
机构
[1] Sungkyunkwan Univ, Dept Radiol, Kangbuk Samsung Hosp, Sch Med, Seoul, South Korea
[2] Inje Univ, Ilsan Paik Hosp, Sch Med, Dept Diagnost Radiol, Goyang, Gyeonggi, South Korea
关键词
liver interventional procedures; radiofrequency ablation; alcohol ablation; experimental study; liver interventional procedure;
D O I
10.1007/s00270-005-0047-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to assess the efficacy of a new perfused-cooled electrode that uses a single pump for creating a large ablation zone in explanted bovine liver. This was done by comparing with the radiofrequency (RF) ablation zones that were created with a monopolar cooled electrode to the RF ablation zones that were created by the new perfused-cooled electrode. We developed a new perfused-cooled electrode that uses a single pump by modifying a 17-gauge cooled electrode (Radionics) with a 2.5-cm outer metallic sheath (15-gauge) in order to allow use of the internal cooling water (5.85 % hypertonic saline) for the infused saline. Thirty ablation zones were created in explanted bovine livers (12-min ablation cycle; pulsed technique; 2000 mA, maximum) with three different regimens: group A, RF ablation with the 17-gauge cooled electrode; group B, RF ablation with the 15-gauge cooled electrode; group C, RF ablation with the perfused-cooled electrode. T2-weighted magnetic resonance (MR) imaging was obtained immediately after RF ablation for calculating volumes of the ablation zone. Following MR imaging, the ablation zones were excised and measured for transverse diameters and vertical diameters. The transverse diameter, vertical diameter, and the calculated volumes of the ablation zones on MR imaging were compared among the groups. Ablation zones created with the perfused-cooled electrode (group Q were significantly larger than those created with the 17-gauge cooled electrode (group A) and the 15-gauge cooled electrode (group B) according to the transverse diameter and vertical diameter on the gross specimens (p < 0.05): 3.6 +/- 0.38 cm and 4.4 +/- 0.20 cm in group A, 3.7 +/- 0.08 cm and 4.6 +/- 0.16 cm in group 13, and 5.4 +/- 0.65 cm and 6.0 +/- 0.56 cm in group C, respectively. On the MR imaging, the calculated volumes of the ablation zones in group C were significantly larger than those in groups A and B (p < 0.05): 23.1 +/- 8.7 cm(3) in group A, 28.9 +/- 5.7 cm(3) in group B, and 80.0 +/- 34 cm(3) in group C, respectively. A new perfused-cooled electrode using a single pump could efficiently increase the size of the ablation zone in liver compared with a monopolar cooled electrode, and this was due to its simultaneous use of internal cooling and saline infusion.
引用
收藏
页码:779 / 788
页数:10
相关论文
共 33 条
[11]  
GOLDBERG SN, 1995, ACAD RADIOL, V2, P670
[12]   Large-volume tissue ablation with radio frequency by using a clustered, internally cooled electrode technique: Laboratory and clinical experience in liver metastases [J].
Goldberg, SN ;
Solbiati, L ;
Hahn, PF ;
Cosman, E ;
Conrad, JE ;
Fogle, R ;
Gazelle, GS .
RADIOLOGY, 1998, 209 (02) :371-379
[13]  
GOLDBERG SN, 1995, ACAD RADIOL, V2, P399
[14]  
Goldberg SN, 1996, ACAD RADIOL, V3, P636
[15]   Radio-frequency thermal ablation with NaCl solution injection: Effect of electrical conductivity on tissue heating and coagulation-phantom and porcine liver study [J].
Goldberg, SN ;
Ahmed, M ;
Gazelle, GS ;
Kruskal, JB ;
Huertas, JC ;
Halpern, EF ;
Oliver, BS ;
Lenkinski, RE .
RADIOLOGY, 2001, 219 (01) :157-165
[16]   Percutaneous saline-enhanced radiofrequency ablation of unresectable hepatic tumors:: Initial experience in 26 patients [J].
Kettenbach, J ;
Köstler, W ;
Rücklinger, E ;
Gustorff, B ;
Hüpfl, M ;
Wolf, F ;
Peer, K ;
Weigner, M ;
Lammer, J ;
Müller, W ;
Goldberg, SN .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (06) :1537-1545
[17]   MR imaging-histopathologic correlation of radiofrequency thermal ablation lesion in a rabbit liver model: Observation during acute and chronic stages [J].
Lee, JD ;
Lee, JM ;
Kim, SW ;
Kim, CS ;
Mun, WS .
KOREAN JOURNAL OF RADIOLOGY, 2001, 2 (03) :151-158
[18]   Saline-enhanced hepatic radiofrequency ablation using a perfused-cooled electrode: Comparison of dual probe bipolar mode with monopolar and single probe bipolar modes [J].
Lee, JM ;
Han, JK ;
Kim, SH ;
Lee, JY ;
Kim, DJ ;
Lee, MW ;
Cho, GG ;
Han, CJ ;
Choi, BI .
KOREAN JOURNAL OF RADIOLOGY, 2004, 5 (02) :121-127
[19]   Saline-enhanced radio-frequency tissue ablation in the treatment of liver metastases [J].
Livraghi, T ;
Goldberg, SN ;
Monti, F ;
Bizzini, A ;
Lazzaroni, S ;
Meloni, F ;
Pellicano, S ;
Solbiati, L ;
Gazelle, GS .
RADIOLOGY, 1997, 202 (01) :205-210
[20]   Hepatocellular carcinoma: Radio-frequency ablation of medium and large lesions [J].
Livraghi, T ;
Goldberg, SN ;
Lazzaroni, S ;
Meloni, F ;
Ierace, T ;
Solbiati, L ;
Gazelle, GS .
RADIOLOGY, 2000, 214 (03) :761-768