Novel Signal Noise Reduction Method through Cluster Analysis, Applied to Photoplethysmography

被引:29
作者
Waugh, William [1 ]
Allen, John [1 ,2 ]
Wightman, James [2 ]
Sims, Andrew J. [1 ,2 ]
Beale, Thomas A. W. [1 ,2 ]
机构
[1] Newcastle Univ, Inst Cellular Med, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
[2] Newcastle Tyne NHS Fdn Trust, Northern Med Phys & Clin Engn, Newcastle Upon Tyne NE7 7DN, Tyne & Wear, England
基金
美国国家卫生研究院;
关键词
PERIPHERAL ARTERIAL-DISEASE;
D O I
10.1155/2018/6812404
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Physiological signals can often become contaminated by noise from a variety of origins. In this paper, an algorithm is described for the reduction of sporadic noise from a continuous periodic signal. The design can be used where a sample of a periodic signal is required, for example, when an average pulse is needed for pulse wave analysis and characterization. The algorithm is based on cluster analysis for selecting similar repetitions or pulses from a periodic single. This method selects individual pulses without noise, returns a clean pulse signal, and terminates when a sufficiently clean and representative signal is received. The algorithm is designed to be sufficiently compact to be implemented on a microcontroller embedded within a medical device. It has been validated through the removal of noise from an exemplar photoplethysmography (PPG) signal, showing increasing benefit as the noise contamination of the signal increases. The algorithm design is generalised to be applicable for a wide range of physiological (physical) signals.
引用
收藏
页数:8
相关论文
共 18 条
[1]   A prospective comparison of bilateral photoplethysmography versus the ankle-brachial pressure index for detecting and quantifying lower limb peripheral arterial disease [J].
Allen, John ;
Overbeck, Klaus ;
Nath, Alexander F. ;
Murray, Alan ;
Stansby, Gerard .
JOURNAL OF VASCULAR SURGERY, 2008, 47 (04) :794-802
[2]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[3]  
Challoner A. V. J., 1979, NONINVASIVE PHYSL ME, P1125
[4]   Identifying and reducing noise in psychophysiological recordings [J].
Cutmore, TRH ;
James, DA .
INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 1999, 32 (02) :129-150
[5]  
ELGENDI M, 2016, BIOENGINEERING-BASEL, V3, DOI DOI 10.3390/BIOENGINEERING3040021
[6]  
Estivill-Castro Vladimir, 2002, ACM SIGKDD Explorations Newsletter, V4, P65, DOI [DOI 10.1145/568574.568575, 10.1145/568574.568575]
[7]   SKIN PHOTOPLETHYSMOGRAPHY - A REVIEW [J].
KAMAL, AAR ;
HARNESS, JB ;
IRVING, G ;
MEARNS, AJ .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1989, 28 (04) :257-269
[8]  
Lyons R.G., 2004, Understanding Digital Signal Processing, V2nd ed.
[9]   Effectiveness of Wavelet Denoising on Electroencephalogram Signals [J].
Mamun, Md. ;
Al-Kadi, Mahmoud ;
Marufuzzaman, Mohd. .
JOURNAL OF APPLIED RESEARCH AND TECHNOLOGY, 2013, 11 :156-160
[10]  
Nichols WW, 1990, MCDONALDS BLOOD FLOW