Robust method for 3D arterial spin labeling in mice

被引:14
作者
Chugh, Brige Paul [1 ,2 ]
Bishop, Jonathan [1 ]
Zhou, Yu-Qing [1 ]
Wu, Jian [1 ,3 ,4 ]
Henkelman, R. Mark [1 ,2 ]
Sled, John G. [1 ,2 ]
机构
[1] Hosp Sick Children, Mouse Imaging Ctr, Toronto, ON M5T 3H7, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[3] Fudan Univ, Zhongshan Hosp, Shanghai Inst Cardiovasc Dis, Shanghai 200433, Peoples R China
[4] Fudan Univ, Inst Biomed Sci, Shanghai 200433, Peoples R China
关键词
arterial spin labeling; cerebral blood flow; mouse; CEREBRAL-BLOOD-FLOW; CAPILLARY WATER PERMEABILITY; MAGNETIZATION-TRANSFER; MOUSE-BRAIN; RAT-BRAIN; ADIABATIC INVERSION; T-2; RELAXATION; TRANSIT-TIME; SINGLE-COIL; IN-VIVO;
D O I
10.1002/mrm.23209
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Arterial spin labeling is a versatile perfusion quantification methodology, which has the potential to provide accurate characterization of cerebral blood flow (CBF) in mouse models. However, a paucity of physiological data needed for accurate modeling, more stringent requirements for gradient performance, and strong artifacts introduced by magnetization transfer present special challenges for accurate CBF mapping in the mouse. This article describes robust mapping of CBF over three-dimensional brain regions using amplitude-modulated continuous arterial spin labeling. To provide physiological data for CBF modeling, the carotid artery blood velocity distribution was characterized using pulsed-wave Doppler ultrasound. These blood velocity measurements were used in simulations that optimize inversion efficiency for parameters meeting MRI gradient duty cycle constraints. A rapid slice positioning algorithm was developed and evaluated to provide accurate positioning of the labeling plane. To account for enhancement of T1 due to magnetization transfer, a binary spin bath model of magnetization transfer was used to provide a more accurate estimate of CBF. Finally, a study of CBF was conducted on 10 mice with findings of highly reproducible inversion efficiency (mean +/- standard-error-of-the-mean, 0.67 +/- 0.03), statistically significant variation in CBF over 12 brain regions (P < 0.0001) and a mean +/- standard-error-of-the-mean whole brain CBF of 219 +/- 6 mL/100 g/min. Magn Reson Med, 2012. (C) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:98 / 106
页数:9
相关论文
共 48 条
[11]  
2-5
[12]   Axterial spin labeling: Validity testing and comparison studies [J].
Ewing, JR ;
Cao, Y ;
Knight, RA ;
Fenstermacher, JD .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (06) :737-740
[13]   Single-coil arterial spin-tagging for estimating cerebral blood flow as viewed from the capillary: Relative contributions of intra- and extravascular signal [J].
Ewing, JR ;
Cao, Y ;
Fenstermacher, J .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :465-475
[14]   Murine orthostatic response during prolonged vertical studies: Effect on cerebral blood flow measured by arterial spin-labeled MRI [J].
Foley, LM ;
Hitchens, TK ;
Kochanek, PM ;
Melick, JA ;
Jackson, EK ;
Ho, C .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (04) :798-806
[15]   Extracting branching tubular object geometry via cores [J].
Fridman, Y ;
Pizer, SM ;
Aylward, S ;
Bullitt, E .
MEDICAL IMAGE ANALYSIS, 2004, 8 (03) :169-176
[16]   Dependence of Blood R2 Relaxivity on CPMG Echo-Spacing at 2.35 and 7 T [J].
Gardener, Alexander G. ;
Francis, Susan T. ;
Prior, Malcolm ;
Peters, Andrew ;
Gowland, Penny A. .
MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (04) :967-974
[17]   Quantitative measurements of proton spin-lattice (T1) and spin-spin (T2) relaxation times in the mouse brain at 7.0 T [J].
Guilfoyle, DN ;
Dyakin, VV ;
O'Shea, J ;
Pell, GS ;
Helpern, JA .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (03) :576-580
[18]   Cerebral perfusion during anesthesia with fentanyl, isoflurane, or pentobarbital in normal rats studied by arterial spin-labeled MRI [J].
Hendrich, KS ;
Kochanek, PM ;
Melick, JA ;
Schiding, JK ;
Statler, KD ;
Williams, DS ;
Marion, DW ;
Ho, C .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :202-206
[19]   QUANTITATIVE INTERPRETATION OF MAGNETIZATION-TRANSFER [J].
HENKELMAN, RM ;
HUANG, XM ;
XIANG, QS ;
STANISZ, GJ ;
SWANSON, SD ;
BRONSKILL, MJ .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) :759-766
[20]   MEASUREMENT OF LOCAL CEREBRAL BLOOD-FLOW WITH [C-14] IODOANTIPYRINE IN THE MOUSE [J].
JAY, TM ;
LUCIGNANI, G ;
CRANE, AM ;
JEHLE, J ;
SOKOLOFF, L .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (01) :121-129