Decoupling of folded-end dipole antenna elements of a 9.4 T human head array using an RF shield

被引:17
作者
Avdievich, Nikolai, I [1 ]
Solomakha, Georgiy [2 ]
Ruhm, Loreen [1 ]
Scheffler, Klaus [1 ,3 ]
Henning, Anke [1 ,4 ]
机构
[1] Max Planck Inst Biol Cybernet, High Field MR Ctr, Tubingen, Germany
[2] ITMO Univ, Dept Phys & Engn, St Petersburg, Russia
[3] Univ Tubingen, Dept Biomed Magnet Resonance, Tubingen, Germany
[4] Univ Texas Southwestern Med Ctr Dallas, Adv Imaging Res Ctr, Dallas, TX 75390 USA
基金
欧洲研究理事会; 俄罗斯科学基金会;
关键词
array optimization; decoupling of dipole antennas; human head transceiver array; transmit performance; ultra-high field MRI; whole-brain coverage; TEM VOLUME COIL; HUMAN BRAIN; TRANSMIT; FIELD; MR; HOMOGENEITY; DESIGN;
D O I
10.1002/nbm.4351
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Dipole antennas have recently been introduced to the field of MRI and successfully used, mostly as elements of ultra-high field (UHF, >= 7 T) human body arrays. Usage of dipole antennas for UHF human head transmit (Tx) arrays is still under development. Due to the substantially smaller size of the sample, dipoles must be made significantly shorter than in the body array. Additionally, head Tx arrays are commonly placed on the surface of rigid helmets made sufficiently large to accommodate tight-fit receive arrays. As a result, dipoles are not well loaded and are often poorly decoupled, which compromises Tx efficiency. Commonly, adjacent array elements are decoupled by circuits electrically connected to them. Placement of such circuits between distantly located dipoles is difficult. Alternatively, decoupling is provided by placing passive antennas between adjacent dipole elements. This method only works when these additional components are sufficiently small (compared with the size of active dipoles). Otherwise, RF fields produced by passive elements interfere destructively with the RF field of the array itself, and previously reported designs have used passive dipoles of about the size of array dipoles. In this work, we developed a novel method of decoupling for adjacent dipole antennas, and used this technique while constructing a 9.4 T human head eight-element transceiver array. Decoupling is provided without any additional circuits by simply folding the dipoles and using an RF shield located close to the folded portion of the dipoles. The array reported in this work demonstrates good decoupling and whole-brain coverage.
引用
收藏
页数:11
相关论文
共 39 条
[1]   Transmit and receive transmission line arrays for 7 tesla parallel imaging [J].
Adriany, G ;
Van de Moortele, PF ;
Wiesinger, F ;
Moeller, S ;
Strupp, JP ;
Andersen, P ;
Snyder, C ;
Zhang, XL ;
Chen, W ;
Pruessmann, KP ;
Boesiger, P ;
Vaughan, T ;
Ugurbil, K .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) :434-445
[2]   Dynamic B0 shimming of the human brain at 9.4 T with a 16-channel multi-coil shim setup [J].
Aghaeifar, Ali ;
Mirkes, Christian ;
Bause, Jonas ;
Steffen, Theodor ;
Avdievitch, Nikolai ;
Henning, Anke ;
Scheffler, Klaus .
MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (04) :1714-1725
[3]   Theoretical and experimental evaluation of detached endcaps for 3 T birdcage coils [J].
Alecci, M ;
Collins, CM ;
Wilson, J ;
Liu, WZ ;
Smith, MB ;
Jezzard, P .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (02) :363-370
[4]   Combination of surface and 'vertical' loop elements improves receive performance of a human head transceiver array at 9.4 T [J].
Avdievich, N. I. ;
Giapitzakis, I. A. ;
Pfrommer, A. ;
Borbath, T. ;
Henning, A. .
NMR IN BIOMEDICINE, 2018, 31 (02)
[5]   Evaluation of transmit efficiency and SAR for a tight fit transceiver human head phased array at 9.4 T [J].
Avdievich, N. I. ;
Hoffmann, J. ;
Shajan, G. ;
Pfrommer, A. ;
Giapitzakis, A. ;
Scheffler, K. ;
Henning, A. .
NMR IN BIOMEDICINE, 2017, 30 (02)
[6]   Bent folded-end dipole head array for ultrahigh-field MRI turns "dielectric resonance" from an enemy to a friend [J].
Avdievich, Nikolai, I ;
Solomakha, Georgiy ;
Ruhm, Loreen ;
Bause, Jonas ;
Scheffler, Klaus ;
Henning, Anke .
MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (06) :3453-3467
[7]   Resonant inductive decoupling (RID) for transceiver arrays to compensate for both reactive and resistive components of the mutual impedance [J].
Avdievich, Nikolai I. ;
Pan, Jullie W. ;
Hetherington, Hoby P. .
NMR IN BIOMEDICINE, 2013, 26 (11) :1547-1554
[8]   Transceiver-Phased Arrays for Human Brain Studies at 7 T [J].
Avdievich, Nikolai I. .
APPLIED MAGNETIC RESONANCE, 2011, 41 (2-4) :483-506
[9]  
Barberi EA, 2000, MAGNET RESON MED, V43, P284, DOI 10.1002/(SICI)1522-2594(200002)43:2<284::AID-MRM16>3.0.CO
[10]  
2-C