Quantitative magnetization transfer ultrashort echo time imaging using a time-efficient 3D multispoke Cones sequence

被引:81
作者
Ma, Ya-Jun [1 ]
Chang, Eric Y. [1 ,2 ]
Carl, Michael [3 ]
Du, Jiang [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, 200 West Arbor Dr, San Diego, CA 92103 USA
[2] VA San Diego Healthcare Syst, Serv Radiol, San Diego, CA USA
[3] GE Healthcare, San Diego, CA USA
关键词
ultrashort echo time; cones; magnetization transfer; two-pool modeling; short T-2 tissues; OFF-RESONANCE SATURATION; IN-VIVO MT; ACHILLES TENDONS; MRI; EXCHANGE; HEALTHY; T-2-ASTERISK; PARAMETERS; T-1;
D O I
10.1002/mrm.26716
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo accelerate the quantitative ultrashort echo time imaging using a time-efficient 3D multispoke Cones sequence with magnetization transfer (3D UTE-Cones-MT) and signal modeling. Theory and MethodsA 3D UTE-Cones-MT acquisition scheme with multispoke per MT preparation and a modified rectangular pulse (RP) approximation was developed for two-pool MT modeling of macromolecular and water components including their relative fractions, relaxation times and exchange rates. Numerical simulation and cadaveric specimens, including human Achilles tendon and bovine cortical bone, were investigated using a clinical 3T scanner. ResultsNumerical simulation showed that the modified RP model provided accurate estimation of MT parameters when multispokes were acquired per MT preparation. For the experiment with the Achilles tendon and cortical bone samples, the macromolecular fractions were 20.42.0% and 59.4 +/- 5.3%, respectively. ConclusionThe 3D multispoke UTE-Cones-MT sequence can be used for fast volumetric assessment of macromolecular and water components in short T-2 tissues. Magn Reson Med 79:692-700, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:692 / 700
页数:9
相关论文
共 29 条
[1]  
Berry I, 1999, J MAGN RESON IMAGING, V9, P441, DOI 10.1002/(SICI)1522-2586(199903)9:3<441::AID-JMRI12>3.0.CO
[2]  
2-R
[3]   UTE Imaging with Simultaneous Water and Fat Signal Suppression Using a Time-Efficient Multispoke Inversion Recovery Pulse Sequence [J].
Carl, Michael ;
Bydder, Graeme M. ;
Du, Jiang .
MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (02) :577-582
[4]   A comparison between equations describing in vivo MT:: The effects of noise and sequence parameters [J].
Cercignani, Mara ;
Barker, Gareth J. .
JOURNAL OF MAGNETIC RESONANCE, 2008, 191 (02) :171-183
[5]   Estimation of in vivo proton intrinsic and cross-relaxation rates in human brain [J].
Chai, JW ;
Chen, C ;
Chen, JH ;
Lee, SK ;
Yeung, HN .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (01) :147-152
[6]   Qualitative and Quantitative Ultrashort Echo Time Imaging of Musculoskeletal Tissues [J].
Chang, Eric Y. ;
Du, Jiang ;
Bae, Won C. ;
Chung, Christine B. .
SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2015, 19 (04) :375-386
[7]   Qualitative and quantitative ultrashort-TE MRI of cortical bone [J].
Du, Jiang ;
Bydder, Graeme M. .
NMR IN BIOMEDICINE, 2013, 26 (05) :489-506
[8]   Ultrashort TE Imaging With Off-Resonance Saturation Contrast (UTE-OSC) [J].
Du, Jiang ;
Takahashi, Atsushi M. ;
Bydder, Mark ;
Chung, Christine B. ;
Bydder, Graeme M. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (02) :527-531
[9]   Diagnostic Value of T1 and T2* Relaxation Times and Off-Resonance Saturation Effects in the Evaluation of Achilles Tendinopathy by MRI at 3T [J].
Grosse, Ulrich ;
Syha, Roland ;
Hein, Tobias ;
Gatidis, Sergios ;
Groezinger, Gerd ;
Schabel, Christoph ;
Martirosian, Petros ;
Schick, Fritz ;
Springer, Fabian .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (04) :964-973
[10]   Ultrashort echo time MR imaging with off-resonance saturation for characterization of pathologically altered Achilles tendons at 3 T [J].
Grosse, Ulrich ;
Syha, Roland ;
Martirosian, Petros ;
Wuerslin, Christian ;
Horger, Marius ;
Groezinger, Gerd ;
Schick, Fritz ;
Springer, Fabian .
MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (01) :184-192