Intra-venous digital subtraction angiography: an alternative method to intra-arterial digital subtraction angiography for experimental aneurysm imaging

被引:16
作者
Ding, YH
Dai, DY
Lewis, DA
Danielson, MA
Kadirvel, R
Mandrekar, JN
Cloft, HJ
Kallmes, DF
机构
[1] Mayo Clin, Dept Radiol, Neuroradiol Res Lab, Rochester, MN 55905 USA
[2] Mayo Clin, Div Biostat, Dept Hlth Sci Res, Rochester, MN USA
关键词
cerebral aneurysm; animal model; elastase; digital subtraction angiography (DSA);
D O I
10.1007/s00234-005-1425-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Conventional intra-arterial digital subtraction angiography (IADSA), which necessitates surgical exposure and ligation of the femoral artery, is an invasive and expensive method of evaluation for experimental elastase-induced aneurysms in rabbits. The purpose of this study was to examine and validate intra-venous digital subtraction angiography (IVDSA) as an alternative to IADSA by comparing their diagnostic accuracies. We performed both IVDSA and IADSA for 24 elastase-induced saccular aneurysms in a rabbit model, 1 month following creation. Aneurysm sizes (neck, width and height) from both the IVDSA and IADSA procedures were evaluated and measured. Comparison of the aneurysm sizes between IVDSA and IADSA were performed with the Wilcoxon paired signed-rank test. All the aneurysms were seen clearly in both the IVDSA and IADSA techniques. Mean sizes of the IVDSA aneurysm neck, width and height were 3.41 +/- 0.80 mm, 3.61 +/- 0.93 mm and 8.07 +/- 2.11 mm, respectively. Mean sizes of the IADSA aneurysm neck, width and height were 3.43 +/- 0.80 mm, 3.66 +/- 0.92 mm and 8.16 +/- 2.25 mm, respectively. No significant difference was found in the sizes of the aneurysm neck, width and height between the two groups (P=0.311, P=0.086 and P=0.258, respectively). IVDSA appears to be an alternative method for evaluating elastase-induced aneurysms in rabbits.
引用
收藏
页码:792 / 795
页数:4
相关论文
共 15 条
[1]  
Adams WM, 2000, AM J NEURORADIOL, V21, P1618
[2]   Creation of saccular aneurysms in the rabbit: A model suitable for testing endovascular devices [J].
Altes, TA ;
Cloft, HJ ;
Short, JG ;
DeGast, A ;
Do, HM ;
Helm, GA ;
Kallmes, DF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) :349-354
[3]   Detection of intracranial aneurysms with multislice CT: comparison with conventional angiography [J].
Dammert, S ;
Krings, T ;
Moller-Hartmann, W ;
Ueffing, E ;
Hans, FJ ;
Willmes, K ;
Mull, M ;
Thron, A .
NEURORADIOLOGY, 2004, 46 (06) :427-434
[4]   Transforming growth factor β-coated platinum coils for endovascular treatment of aneurysms:: An animal study [J].
de Gast, AN ;
Altes, TA ;
Marx, WF ;
Do, HM ;
Helm, GA ;
Kallmes, DF .
NEUROSURGERY, 2001, 49 (03) :690-694
[5]   Multimodal imaging in the elastase-induced aneurysm model in rabbits: A comparative study using serial DSA, MRA and CTA [J].
Doerfler, A ;
Becker, W ;
Wanke, I ;
Goericke, S ;
Oezkan, N ;
Forsting, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (04) :590-596
[6]   RAPID DIAGNOSIS OF THORACIC AORTIC TRANSECTION USING INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHY [J].
EDDY, AC ;
NANCE, DR ;
GOLDMAN, MA ;
CALDWELL, DM ;
COPASS, M ;
VERRIER, ED ;
CARRICO, CJ .
AMERICAN JOURNAL OF SURGERY, 1990, 159 (05) :500-503
[7]  
Fujiwara NH, 2001, AM J NEURORADIOL, V22, P698
[8]  
Kallmes DF, 2003, AM J NEURORADIOL, V24, P591
[9]  
Kallmes DF, 2002, AM J NEURORADIOL, V23, P295
[10]  
Kallmes DF, 2002, AM J NEURORADIOL, V23, P1580