Intraocular lens power calculation in eyes with previous corneal refractive surgery

被引:11
作者
Anders, Philipp [1 ,2 ]
Anders, Lisa-Marie [1 ,2 ]
Barbara, Adel [3 ]
Szentmary, Nora [4 ]
Langenbucher, Achim [5 ]
Gatzioufas, Zisis [1 ,2 ]
机构
[1] Inst Mol & Clin Ophthalmol Basel, CH-4031 Basel, Switzerland
[2] Univ Basel, Dept Ophthalmol, Basel, Switzerland
[3] IVISION Laser Refract Ctr, Haifa, Israel
[4] Saarland Univ, Dr Rolf M Schwiete Ctr Limbal Stem Cell & Congeni, Homburg, Germany
[5] Saarland Univ, Expt Ophthalmol, Homburg, Germany
关键词
cataract; cataract extraction; corneal surgery; excimer laser; IOL power; IOL power miscalculation; keratometry; LASIK; PRK; refractive surgery; RK; SMILE; IN-SITU KERATOMILEUSIS; HOFFER-Q FORMULA; TRUE-K FORMULA; INTRAOPERATIVE ABERROMETRY; RADIAL KERATOTOMY; PHOTOREFRACTIVE KERATECTOMY; HISTORY METHOD; HAIGIS-L; ANTERIOR; BIOMETRY;
D O I
10.1177/25158414221118524
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Intraocular lens (IOL) power calculation after corneal refractive surgery (CRS) becomes an expanding challenge for ophthalmologists as more and more cataract surgeries after CRS are required. These patients typically also have high expectations as to visual performance. Conventional IOL power calculation schemes frequently provide inaccurate results in these cases. This review aims to summarize and recommend currently available IOL power calculation methods for eyes with the most common CRS methods: radial keratotomy (RK), photorefractive keratectomy (PRK), laser in situ keratomileusis (LASIK), and small incision lenticule extraction (SMILE). To this end, biometry measuring methods and IOL formulas will be explained and combinations of both are proposed. In synopsis, it is evident that the latest generation of vergence formulas exhibit favorable IOL power prediction accuracy in post-CRS eyes, even though the predictive precision of methods in eyes without CRS is not attained. Ray tracing computation, intraoperative aberrometry, and machine learning-based formulas hold potential to further improve refractive outcomes in post-CRS eyes.
引用
收藏
页数:10
相关论文
共 62 条
[1]   Accuracy of the Barrett True-K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopia [J].
Abulafia, Adi ;
Hill, Warren E. ;
Koch, Douglas D. ;
Wang, Li ;
Barrett, Graham D. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (03) :363-369
[2]   Intraocular lens power calculation after corneal refractive surgery: Double-K method [J].
Aramberri, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (11) :2063-2068
[3]   Orbscan computerized topography: Attributes, applications, and limitations [J].
Cairns, G ;
McGhee, CNJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) :205-220
[4]   Scheimpflug Camera Measurement of Anterior and Posterior Corneal Curvature in Eyes With Previous Radial Keratotomy [J].
Camellin, Massimo ;
Savini, Giacomo ;
Hoffer, Kenneth J. ;
Carbonelli, Michele ;
Barboni, Piero .
JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (04) :275-279
[5]   Intraoperative Aberrometry Versus Preoperative Biometry for IOL Power Selection After Radial Keratotomy: A Prospective Study [J].
Curado, Sebastiao Xavier ;
Hida, Wilson Takashi ;
Cortez Vilar, Cesar Martins ;
Ordones, Virgilio Luiz ;
Pereira Chaves, Mario Augusto ;
Tzelikis, Patrick Frensel .
JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (10) :656-+
[6]   Anterior chamber depth measurement before and after photorefractive keratectomy. Comparison between IOLMaster and Pentacam [J].
De Bernardo, Maddalena ;
Borrelli, Maria ;
Imparato, Roberto ;
Cione, Ferdinando ;
Rosa, Nicola .
PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2020, 32
[7]   Posterior corneal shape: Comparison of height data from 3 corneal topographers [J].
de Jong, Tim ;
Sheehan, Matthew T. ;
Koopmans, Steven A. ;
Jansonius, Nomdo M. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (04) :518-524
[8]   IOL Power Calculation After Radial Keratotomy Using the Haigis and Barrett True-K Formulas [J].
de Pinho Tavares, Renata Leite ;
Ferreira, Gabriel de Almeida ;
Ghanem, Vinicius Coral ;
Ghanem, Ramon Coral .
JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (12) :832-+
[9]   IOL power calculations after LASIK or PRK: Barrett True-K biometer-only calculation strategy yields equivalent outcomes as a multiple formula approach [J].
Ferguson, Tanner J. ;
Downes, Rachel A. ;
Randleman, J. Bradley .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (07) :784-789
[10]   Color LED reflection topography: validation of equivalent keratometry reading for IOL power calculation in eyes with previous corneal myopic refractive surgery [J].
Fernandez-Roses, Joaquim ;
Lamarca, Jose ;
Hoffer, Kenneth J. ;
Beltran-Saiz, Antonio ;
Barraquer, Rafael I. ;
Savini, Giacomo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (01) :32-36