3x3 Mach-Zehnder interferometer with unbalanced differential detection for full-range swept-source optical coherence tomography

被引:35
作者
Mao, Youxin [1 ]
Sherif, Sherif [1 ]
Flueraru, Costel [1 ]
Chang, Shoude [1 ]
机构
[1] Natl Res Council Canada, Inst Microstruct Sci, Ottawa, ON K1A 0R6, Canada
关键词
D O I
10.1364/AO.47.002004
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Quadrature interferometry based on 3 x 3 fiber couplers could be used to double the effective imaging depth in swept-source optical coherence tomography. This is due to its ability to suppress the complex conjugate artifact naturally. We present theoretical and experimental results for a 3 x 3 Mach-Zehnder interferometer using a new unbalanced differential optical detection method. The new interferometer provides simultaneous access to complementary phase components of the complex interferometric signal. No calculations by trigonometric relationships are needed. We demonstrate a complex conjugate artifact suppression of 27 dB obtained in swept-source optical coherence tomography using our unbalanced differential detection. We show that our unbalanced differential detection has increased the signal-to-noise ratio by at least 4 dB compared to the commonly used balanced detection technique. This is due to better utilization of optical power. (C) 2008 Optical Society of America.
引用
收藏
页码:2004 / 2010
页数:7
相关论文
共 22 条
[1]  
Bouma B.E., 2002, Handbook of Optical Coherence Tomography
[2]   Instantaneous quadrature low-coherence interferometry with 3 x 3 fiber-optic couplers [J].
Choma, MA ;
Yang, CH ;
Izatt, JA .
OPTICS LETTERS, 2003, 28 (22) :2162-2164
[3]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[4]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[5]  
FERCHER F, 1995, OPT COMMUN, V117, P43
[6]   Quadrature Mach-Zehnder interferometer with application in optical coherence tomography [J].
Flueraru, C. ;
Kumazaki, H. ;
Sherif, S. ;
Chang, S. ;
Mao, Y. .
JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2007, 9 (04) :L5-L8
[7]  
Häusler G, 1998, J BIOMED OPT, V3, P21, DOI 10.1117/1.429899
[8]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[9]   Three-dimensional and C-mode OCT imaging with a compact, frequency swept laser source at 1300 nm [J].
Huber, R ;
Wojtkowski, M ;
Fujimoto, JG ;
Jiang, JY ;
Cable, AE .
OPTICS EXPRESS, 2005, 13 (26) :10523-10538
[10]   Amplified, frequency swept lasers for frequency domain reflectometry and OCT imaging: design and scaling principles [J].
Huber, R ;
Wojtkowski, M ;
Taira, K ;
Fujimoto, JG ;
Hsu, K .
OPTICS EXPRESS, 2005, 13 (09) :3513-3528