Influence of passive supplemental damping systems on structural and nonstructural seismic fragilities of a steel building

被引:41
作者
Wanitkorkul, Assawin [1 ]
Filiatrault, Andre [1 ]
机构
[1] SUNY Buffalo, Dept Civil Struct & Environm Engn, Buffalo, NY 14260 USA
基金
美国国家科学基金会;
关键词
seismic fragility; nonstructural components; dampers; retrofit; steel structure;
D O I
10.1016/j.engstruct.2007.05.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of a numerical study on the influence of structural passive supplemental damping systems on structural and nonstructural seismic fragilities of a steel framed building. Hysteretic and viscous bracing systems were used to retrofit a four-storey steel framed building containing generic rigidly anchored and vibration isolated secondary nonstructural components located at various floor levels in the building. The Incremental Dynamic Analysis (IDA) procedure was utilized with an ensemble of 44 scaled historical ground motions to construct structural and nonstructural fragility curves for various performance objectives. The results obtained indicate that both supplemental damping systems improved the seismic behaviour of the original building by increasing the median values of the structural fragility curves and reducing the probabilities of exceedence at the Design Basis Earthquake (DBE) and Maximum Credible Earthquake (MCE) levels. The nonstructural components mounted on vibration isolation systems exhibited reduced seismic fragilities compared to that of rigidly anchored nonstructural components. Retrofitting the building with viscous dampers reduced the seismic fragility of nonstructural components mounted to the roof of the building. Retrofitting the building with hysteretic dampers, on the other hand, was detrimental to the seismic fragility of acceleration sensitive rigidly anchored nonstructural components at the roof level. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:675 / 682
页数:8
相关论文
共 7 条
[1]  
[Anonymous], 12 EUR C EARTHQ ENG
[2]  
[Anonymous], 2000, 356 FEMA ATC
[3]  
*ASHRAE, 2003, ASHRAE HDB, pCH54
[4]  
CARR A, 2004, RUAUMOKO USERS MANUA
[5]  
Christopoulos C., 2006, Principles of Supplemental Damping and Seismic Isolation
[6]  
DEIERLEIN GD, 2006, 63 ATC STANF U NONL
[7]  
*ICBO, 1970, U BUILD COD