Data-Driven Respiratory Signal Extraction for SPECT Imaging Using Laplacian Eigenmaps

被引:0
作者
Sanders, James C. [1 ]
Ritt, Philipp [2 ]
Kuwert, Torsten [2 ]
Vija, A. Hans [3 ]
Hornegger, Joachim [1 ]
机构
[1] Univ Erlangen Nurnberg, Pattern Recognit Lab, Martensstr 3, D-90108 Erlangen, Germany
[2] Univ Hosp Erlangen, Clin Nucl Med, D-91054 Erlangen, Germany
[3] Siemens Healthcare GmbH, Siemens Med Solut USA, Mol Imaging, Hoffman Estates, IL 60169 USA
来源
2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2015年
关键词
Laplacian Eigenmaps; manifold learning; respiratory gating; SPECT; MOTION;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In Single Photon Emission-Computed Tomography (SPECT) imaging, respiratory motion may lead to artifacts and loss of quantitative accuracy. To compensate for this motion, a respiratory surrogate signal representing the patient's respiratory state over time is required. In practice, this surrogate signal is obtained via sensor-based approaches, but we seek to develop a data-driven solution that requires no external hardware. In this work, we compare two such methods, one linear and one non-linear, based on dimensionality reduction: Principle Component Analysis (PCA) and Laplacian Eigenmaps (LE). Our aim is to apply both to conventional SPECT and assess the feasibility of data-driven respiratory surrogate signal extraction for this modality. We expect that LE, which is less sensitive to outliers in data, will outperform PCA at high levels of image noise. Two phantom acquisitions were performed: one in which a sphere in cold background was translated axially by a piston actuator (dynamic), and a warm background with no sphere (static). Using binomial subsampling, both datasets were combined at various Signal-to-Noise Ratios (SNRs). LE and PCA surrogate signals were computed and compared via Pearson's correlation to the truth signal obtained from the actuator. As a follow-up, LE and PCA estimates from 27 cardiac SPECT acquisitions were compared to a simultaneously acquired signal from a pressure sensor embedded in an elastic belt. In the phantom experiment, correlations between LE/ PCA and truth were > 0.9 for all SNR > 5. For SNR < 5, PCA deteriorated rapidly, whereas LE remained stable through SNR=2.5. For the patient validation, LE and PCA yielded average correlations of 0.86 +/- 0.14 and 0.37 +/- 0.26, respectively. The phantom experiment indicated that LE outperforms PCA for low-SNR data. This conclusion was supported by the superior performance of LE for patient datasets, where noise may be high. However, the present work is limited by the simplistic motion present in the phantom experiment and the limited scope of the patient validation.
引用
收藏
页数:4
相关论文
共 10 条
  • [1] Laplacian eigenmaps for dimensionality reduction and data representation
    Belkin, M
    Niyogi, P
    [J]. NEURAL COMPUTATION, 2003, 15 (06) : 1373 - 1396
  • [2] List Mode-Driven Cardiac and Respiratory Gating in PET
    Buether, Florian
    Dawood, Mohammad
    Stegger, Lars
    Wuebbeling, Frank
    Schaefers, Michael
    Schober, Otmar
    Schaefers, Klaus P.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (05) : 674 - 681
  • [3] Motion Correction Strategies for Integrated PET/MR
    Fuerst, Sebastian
    Grimm, Robert
    Hong, Inki
    Souvatzoglou, Michael
    Casey, Michael E.
    Schwaiger, Markus
    Nekolla, Stephan G.
    Ziegler, Sibylle I.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (02) : 261 - 269
  • [4] Respiratory motion in positron emission tomography/computed tomography: A review
    Nehmeh, Sadek A.
    Erdi, Yusuf E.
    [J]. SEMINARS IN NUCLEAR MEDICINE, 2008, 38 (03) : 167 - 176
  • [5] Thielemans K, 2013, P IEEE NUCL SCI S ME, P1
  • [6] Thielemans K, 2011, IEEE NUCL SCI CONF R, P3904, DOI 10.1109/NSSMIC.2011.6153742
  • [7] Tukey J.W, 1977, Exploratory Data Analysis, P43
  • [8] Van der Maaten L. J. P., 2009, J MACH LEARN RES, V10
  • [9] Manifold learning for image-based breathing gating in ultrasound and MRI
    Wachinger, Christian
    Yigitsoy, Mehmet
    Rijkhorst, Erik-Jan
    Navab, Nassir
    [J]. MEDICAL IMAGE ANALYSIS, 2012, 16 (04) : 806 - 818
  • [10] Zeintl J, 2011, IEEE NUCL SCI CONF R, P2426, DOI 10.1109/NSSMIC.2011.6152660