Randomized controlled trial of aspiration needle versus automated biopsy device for transjugular liver biopsy

被引:26
作者
Bañares, R
Alonso, S
Catalina, MV
Casado, M
Rincón, D
Salcedo, M
Alvarez, E
Guerrero, C
Echenagusía, A
Camúñez, F
Simó, G
机构
[1] Univ Complutense Madrid, Hepat Hemodynam Lab, Dept Gastroenterol, Hosp Gen Gregorio Maranon, Madrid 28007, Spain
[2] Univ Complutense Madrid, Hosp Gen Gregorio Maranon, Dept Pathol, Madrid 28007, Spain
[3] Univ Complutense Madrid, Hosp Gen Gregorio Maranon, Dept Radiol, Madrid 28007, Spain
关键词
biopsies; technology; liver; biopsy;
D O I
10.1016/S1051-0443(07)61479-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: The efficacy and safety of transjugular liver biopsy used to obtain liver specimens in patients with coagulation disorders have been widely proven. However, histopathologic examination is not always possible because of fragmented samples provided by the aspiration technique. Recently, an automated device with a Tru-Cut-type needle was designed. In this randomized controlled trial, the use of this new device is compared with the traditional method in terms of efficacy and safety. METHOD: Fifty-six patients were included in the study; 28 were randomized to undergo the aspiration technique and 28 were randomized to undergo the automated biopsy technique. RESULTS: Correct positioning of the device was achieved in 93% of patients undergoing the aspiration technique and 96% of patients undergoing the automated biopsy technique (P = NS). Mean duration of the procedure and total number of passes were significantly higher in the aspiration needle group than in the automated device group (22.6 min +/- 12.6 vs 15.5 min +/- 9.4; P = .03, and 3.3 min +/- 1.9 vs 1.5 min +/- 0.63; P < .001, respectively). The number of portal tracts was significantly higher in the automated device group (4.7 +/- 2.5 vs. 2.7 +/- 3.4; P < .05). Adequate specimens for histopathologic evaluation were obtained in 26 patients in the automated device group and 24 patients in the aspiration needle group (92.8% vs 85.7%; P = NS), but a definite histopathologic diagnosis was more frequently obtained with the automated biopsy device (68% vs 43%; P = .05). No significant differences were observed in complication rates (7.14% vs. 10.7%; P = NS). CONCLUSION: The automated biopsy device for transjugular liver biopsy is more effective than an aspiration needle in obtaining good samples for a definite histologic diagnosis.
引用
收藏
页码:583 / 587
页数:5
相关论文
共 12 条
[1]   EXPERIENCE WITH TRANSJUGULAR LIVER-BIOPSY [J].
BULL, HJM ;
GILMORE, IT ;
BRADLEY, RD ;
MARIGOLD, JH ;
THOMPSON, RPH .
GUT, 1983, 24 (11) :1057-1060
[2]   Transjugular liver biopsy in 52 patients with an automated Trucut-type needle [J].
De Hoyos, A ;
Loredo, ML ;
Martínez-Ríos, MA ;
Gil, MR ;
Kuri, J ;
Cárdenas, M .
DIGESTIVE DISEASES AND SCIENCES, 1999, 44 (01) :177-180
[3]   TRANSJUGULAR LIVER-BIOPSY - A REVIEW OF 461 BIOPSIES [J].
GAMBLE, P ;
COLAPINTO, RF ;
STRONELL, RD ;
COLMAN, JC ;
BLENDIS, L .
RADIOLOGY, 1985, 157 (03) :589-593
[4]   TRANSJUGULAR LIVER-BIOPSY [J].
GILMORE, IT ;
BRADLEY, RD ;
THOMPSON, RPH .
BRITISH MEDICAL JOURNAL, 1977, 2 (6079) :100-101
[5]  
Gorriz E, 1996, CARDIOVASC INTER RAD, V19, P442
[6]   Transjugular liver biopsy with an automated device [J].
Kardache, M ;
Soyer, P ;
Boudiaf, M ;
CochandPriollet, B ;
Pelage, JP ;
Rymer, R .
RADIOLOGY, 1997, 204 (02) :369-372
[7]  
LEBREC D, 1982, GASTROENTEROLOGY, V83, P338
[8]   Transjugular liver biopsy: A prospective study in 43 patients with the quick-core biopsy needle [J].
Little, AF ;
Zajko, AB ;
Orons, PD .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 7 (01) :127-131
[9]   TRANSJUGULAR LIVER-BIOPSY [J].
MCAFEE, JH ;
KEEFFE, EB ;
LEE, RG ;
ROSCH, J .
HEPATOLOGY, 1992, 15 (04) :726-732
[10]   A 21-YEAR EXPERIENCE WITH MAJOR HEMORRHAGE AFTER PERCUTANEOUS LIVER-BIOPSY [J].
MCGILL, DB ;
RAKELA, J ;
ZINSMEISTER, AR ;
OTT, BJ .
GASTROENTEROLOGY, 1990, 99 (05) :1396-1400