Accuracy of vertebral puncture in percutaneous vertebroplasty

被引:6
作者
Noguchi, Tomoyuki [1 ,2 ,3 ,4 ]
Yamashita, Koji [1 ]
Shida, Yoshitaka [3 ]
Okafuji, Takashi [3 ]
Kamei, Ryotaro [1 ]
Maehara, Junki [1 ]
Tajima, Tsuyoshi [3 ]
机构
[1] Natl Hosp Org, Dept Radiol, Kyushu Med Ctr, Chuo Ku, 1-8-1 Jigyohama, Fukuoka, Fukuoka 8108563, Japan
[2] Natl Hosp Org, Dept Clin Res, Kyushu Med Ctr, Chuo Ku, 1-8-1 Jigyohama, Fukuoka, Fukuoka 8108563, Japan
[3] Natl Ctr Global Hlth & Med, Dept Radiol, Ctr Hosp, Ctr Clin Sci,Shinjuku Ku, 1-21-1 Toyama, Tokyo 1628655, Japan
[4] Natl Ctr Global Hlth & Med, Ctr Clin Sci, Dept Clin Res, Educ & Training Off,Shinjuku Ku, 1-21-1 Toyama, Tokyo 1628655, Japan
关键词
Vertebroplasty; Punctures; Spine; Needles; Back pain; TRANSPEDICULAR BIOPSY; COMPRESSION FRACTURE; INJECTION; SPINE;
D O I
10.1007/s11604-021-01216-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To clarify the accuracy of vertebral puncture of the vertebral tertile area needling (VETERAN) method puncturing the pedicle superimposed on one-third of the width between the lateral vertebral line to the contralateral medial lamina line compared with Cathelin-needle-assisted puncture (CAP) method puncturing using the Cathelin needle as a guide in percutaneous vertebroplasty. Materials and methods 449 punctures by CAP method and 125 punctures by VETERAN method were enrolled. We compared the puncture accuracy of both methods. We estimated a vertebral estimated tilting ratio (VET-ratio) defined as ratio of the distance between the lateral vertebral line and the contralateral medial laminal line to the distance between the vertebral lateral line and the puncture point measured by computed tomography. We also estimated the procedural items and clinical outcomes. Results VETERAN method with 100% of punctures within safe zone (cortical breaches within 2 mm) had significantly higher accuracy than CAP method with 97.8% (p < 0.01) for the 2 mm incremental evaluation. No cases with a VET-ratio of 36% or less had cortical breaches. VETERAN method had shorter operative time per puncture (p < 0.01) and exposure time per puncture (p < 0.05). Conclusion VETERAN method reduced the occurrence of the inaccurate puncture, operative times, and exposure times. A VET-ratio with 36% or less is associated with a safe puncture using VETERAN method.
引用
收藏
页码:419 / 429
页数:11
相关论文
共 50 条
  • [31] Percutaneous vertebroplasty in multiple myeloma vertebral involvement
    Masala, Salvatore
    Anselmetti, Giovanni Carlo
    Marcia, Stefano
    Massari, Franeesco
    Manca, Antonio
    Simonetti, Giovanni
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2008, 21 (05): : 344 - 348
  • [32] Therapeutic effects of percutaneous vertebroplasty for vertebral metastases
    Yuji Mikami
    Yuji Numaguchi
    Nobuo Kobayashi
    Sokun Fuwa
    Yoshimitsu Hoshikawa
    Yukihisa Saida
    Japanese Journal of Radiology, 2011, 29 : 202 - 206
  • [33] A design of a targeted puncture trajectory applied to unilateral extrapedicular percutaneous vertebroplasty
    Zhang, Tao
    Deng, Yinghu
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [34] Percutaneous vertebral augmentation: Vertebroplasty, kyphoplasty and skyphoplasty
    Peh, Wilfred C. G.
    Munk, Peter L.
    Rashid, Faisal
    Gilula, Louis A.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2008, 46 (03) : 611 - +
  • [35] Complications in Percutaneous Vertebroplasty Associated with Puncture or Cement Leakage
    Clemens Baumann
    Heiko Fuchs
    Jürgen Kiwit
    Kerstin Westphalen
    Johannes Hierholzer
    CardioVascular and Interventional Radiology, 2007, 30 : 161 - 168
  • [36] Percutaneous vertebral puncture biopsy and MRI are useful in diagnosis of malignant vertebral fractures
    Zou, Debo
    Ren, Yanjun
    Zhang, Kaining
    Wu, Yingguang
    Yang, Yun
    Li, Wenbin
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (06): : 12404 - 12410
  • [37] Complications in percutaneous vertebroplasty associated with puncture or cement leakage
    Baumann, Clemens
    Fuchs, Heiko
    Kiwit, Jurgen
    Westphalen, Kerstin
    Hierholzer, Johannes
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (02) : 161 - 168
  • [38] Cold defect on bone scan in a vertebral body after percutaneous vertebroplasty
    Lavely, William C.
    Malhotra, Amit D.
    Ziessman, Harvey A.
    Murphy, Kieran P. J.
    SKELETAL RADIOLOGY, 2006, 35 (12) : 946 - 948
  • [39] Progression toward Vertebral Collapse of Vertebral Metastases Treated with Percutaneous Vertebroplasty: Rate and Risk Factors
    Dargelos-Descoubez, Marion
    Martin, Florian
    Frampas, Eric
    Perret, Christophe
    David, Arthur
    Volpi, Stephanie
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2024, 35 (01) : 59 - 68
  • [40] Percutaneous vertebroplasty in the management of osteoporotic vertebral compression fractures: Initial experience
    Tsou, IYY
    Goh, PYT
    Peh, WCG
    Goh, LA
    Chee, TSG
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2002, 31 (01) : 15 - 20