Accuracy of vertebral puncture in percutaneous vertebroplasty

被引:6
作者
Noguchi, Tomoyuki [1 ,2 ,3 ,4 ]
Yamashita, Koji [1 ]
Shida, Yoshitaka [3 ]
Okafuji, Takashi [3 ]
Kamei, Ryotaro [1 ]
Maehara, Junki [1 ]
Tajima, Tsuyoshi [3 ]
机构
[1] Natl Hosp Org, Dept Radiol, Kyushu Med Ctr, Chuo Ku, 1-8-1 Jigyohama, Fukuoka, Fukuoka 8108563, Japan
[2] Natl Hosp Org, Dept Clin Res, Kyushu Med Ctr, Chuo Ku, 1-8-1 Jigyohama, Fukuoka, Fukuoka 8108563, Japan
[3] Natl Ctr Global Hlth & Med, Dept Radiol, Ctr Hosp, Ctr Clin Sci,Shinjuku Ku, 1-21-1 Toyama, Tokyo 1628655, Japan
[4] Natl Ctr Global Hlth & Med, Ctr Clin Sci, Dept Clin Res, Educ & Training Off,Shinjuku Ku, 1-21-1 Toyama, Tokyo 1628655, Japan
关键词
Vertebroplasty; Punctures; Spine; Needles; Back pain; TRANSPEDICULAR BIOPSY; COMPRESSION FRACTURE; INJECTION; SPINE;
D O I
10.1007/s11604-021-01216-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To clarify the accuracy of vertebral puncture of the vertebral tertile area needling (VETERAN) method puncturing the pedicle superimposed on one-third of the width between the lateral vertebral line to the contralateral medial lamina line compared with Cathelin-needle-assisted puncture (CAP) method puncturing using the Cathelin needle as a guide in percutaneous vertebroplasty. Materials and methods 449 punctures by CAP method and 125 punctures by VETERAN method were enrolled. We compared the puncture accuracy of both methods. We estimated a vertebral estimated tilting ratio (VET-ratio) defined as ratio of the distance between the lateral vertebral line and the contralateral medial laminal line to the distance between the vertebral lateral line and the puncture point measured by computed tomography. We also estimated the procedural items and clinical outcomes. Results VETERAN method with 100% of punctures within safe zone (cortical breaches within 2 mm) had significantly higher accuracy than CAP method with 97.8% (p < 0.01) for the 2 mm incremental evaluation. No cases with a VET-ratio of 36% or less had cortical breaches. VETERAN method had shorter operative time per puncture (p < 0.01) and exposure time per puncture (p < 0.05). Conclusion VETERAN method reduced the occurrence of the inaccurate puncture, operative times, and exposure times. A VET-ratio with 36% or less is associated with a safe puncture using VETERAN method.
引用
收藏
页码:419 / 429
页数:11
相关论文
共 50 条
  • [1] Accuracy of vertebral puncture in percutaneous vertebroplasty
    Tomoyuki Noguchi
    Koji Yamashita
    Yoshitaka Shida
    Takashi Okafuji
    Ryotaro Kamei
    Junki Maehara
    Tsuyoshi Tajima
    Japanese Journal of Radiology, 2022, 40 : 419 - 429
  • [2] Percutaneous vertebroplasty for single osteoporotic vertebral body compression fractureResults of unilateral 3-D percutaneous puncture technique
    Hong-De Li
    Chuan-Jun Xu
    Hong Wang
    Wen Liu
    Xi-Jing Jiang
    Xi-Qi Zhu
    Indian Journal of Orthopaedics, 2015, 49 : 245 - 250
  • [3] Percutaneous vertebroplasty: a therapeutic option for pain associated with vertebral compression fracture
    Mathis, JM
    Eckel, TS
    Belkoff, SM
    Deramond, H
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 1999, 13 (01) : 11 - 17
  • [4] Percutaneous vertebroplasty: An emerging therapy for vertebral compression fractures
    Ng, PP
    Caragine, LP
    Dowd, CF
    SEMINARS IN NEUROLOGY, 2002, 22 (02) : 149 - 155
  • [5] Single Level Percutaneous Vertebroplasty for Vertebral Hemangiomata - A Review of Outcomes
    Nambiar, Mithun
    Maingard, Julian T.
    Onggo, James R.
    Phan, Kevin
    Asadi, Hamed
    Brooks, Duncan Mark
    Hirsch, Joshua A.
    Chandra, Ronil, V
    Anselmetti, Giovanni
    PAIN PHYSICIAN, 2020, 23 (06) : E637 - E642
  • [6] Osteoporotic vertebral collapse:: Percutaneous vertebroplasty and local kyphosis correction
    Carlier, RY
    Gordji, H
    Mompoint, DM
    Vernhet, N
    Feydy, A
    Vallée, C
    RADIOLOGY, 2004, 233 (03) : 891 - 898
  • [7] Percutaneous vertebroplasty for severe osteoporotic vertebral body compression fractures
    Peh, WCG
    Gilula, LA
    Peck, DD
    RADIOLOGY, 2002, 223 (01) : 121 - 126
  • [8] Effects of Facet Joint Injection Reducing the Need for Percutaneous Vertebroplasty in Vertebral Compression Fractures
    Tae Seong Im
    Joon Woo Lee
    Eugene Lee
    Yusuhn Kang
    Joong Mo Ahn
    Heung Sik Kang
    CardioVascular and Interventional Radiology, 2016, 39 : 740 - 745
  • [9] Effects of Facet Joint Injection Reducing the Need for Percutaneous Vertebroplasty in Vertebral Compression Fractures
    Im, Tae Seong
    Lee, Joon Woo
    Lee, Eugene
    Kang, Yusuhn
    Ahn, Joong Mo
    Kang, Heung Sik
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 39 (05) : 740 - 745
  • [10] Percutaneous vertebroplasty in the therapy of osteoporotic vertebral compression fractures: a critical review
    K. Hochmuth
    D. Proschek
    W. Schwarz
    M. Mack
    A. A. Kurth
    T. J. Vogl
    European Radiology, 2006, 16