Three-dimensional ultrasound-guided embryo transfer: A preliminary study

被引:16
|
作者
Letterie, GS [1 ]
机构
[1] Virginia Mason Med Ctr, Ctr Fertil & Reprod Endocrinol, Seattle, WA 98101 USA
关键词
three-dimensional ultrasound; embryo transfer; in vitro fertilization;
D O I
10.1016/j.ajog.2005.02.044
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: Embryo transfer techniques have emerged Lis 1 of the most important variables during in vitro fertilization. Two-dimensional ultrasound guidance is an integral part of this procedure and a method to monitor catheter passage through the cervix into the endometrial cavity. Catheter placement may better be achieved with 3-dimensional monitoring to assess the relationship of the catheter tip to the uterine cavity. The purpose of this study was to compare the precision of catheter placement and position by 2- and 3-dimensional ultrasound. Study design: Twenty-four patients were studied. The cervix, Uterus, and endometrial cavity were prescreened in 2 dimensions at the midline in the longitudinal plane of the uterus. Embryo transfers were then performed Under 2-dimensional guidance. After satisfactory catheter placement and transfer of the embryos, the catheter was held in place for 60 to 120 seconds. During this interval, an automated, single sweep of the uterus and endometrial cavity was performed for net volume acquisition. All images were stored and retrospectively reviewed. Embryo transfer catheter placement with 2-dimensional Ultrasound guidance was then compared with the images obtained in 3 Simultaneous planes. Results: Visualization of the embryo catheter tip with 2-dimensional Ultrasound was achieved in all patients. These images suggested that the catheter was 2 cm from the uterine fundus and in the midline. Satisfactory 3-dimensional images for review and comparison were obtained in 21 of 24 patients. Three-dimensional ultrasound images confirmed placement and agreed with findings 9 of 2-dimensional ultrasound images in 17 of 21 patients. In 4 patients, the catheter tip on 3-dimensional Ultrasound was observed to be displaced either anteriorly or laterally from the ideal region as suggested by 2-dimensional ultrasound. In 1 case, the catheter tip on 3-dimensional Ultrasound was observed to be far laterally in the region of the uterine cornua. Conclusion: Two-dimensional ultrasound-guided embryo transfer Continues to be the standard for image-guided transfers. Data of the present Study Suggest that the precision of catheter tip placement and consequently embryo transfer may be improved with 3-dimensional imaging. Four of 21 patients Studied had catheter tip placement in a different and less-than-ideal area when Studied with 3-dimensional ultrasound. Three-dimensional imaging may provide an improvement in embryo transfer technique and have a positive impact oil overall pregnancy rates. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:1983 / 1987
页数:5
相关论文
共 50 条
  • [41] A Cross-sectional Study to Determine Pregnancy Outcomes in Transabdominal Ultrasound-guided Embryo Transfer
    Jamwal, Vishan Dev Singh
    Jamwal, Shallu
    Sharma, Rajesh
    Tandon, Aseem
    Jha, Rahul
    Acharya, Alok P.
    Bhukya, Subhash
    JOURNAL OF THE ANATOMICAL SOCIETY OF INDIA, 2024, 73 (01) : 60 - 63
  • [42] Ultrasound-guided infraclavicular block: a preliminary study of feasibility
    Bloc, S.
    Garnier, T.
    Komly, B.
    Leclerc, P.
    Mercadal, L.
    Morel, B.
    Dhonneur, G.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2007, 26 (7-8): : 627 - 632
  • [43] Three-dimensional ultrasound-guided biopsy of breast lesion: a new diagnostic support in the preoperative diagnosis
    L Delle Chiaie
    S Schindelmann
    I Heinich
    V Heilmann
    G Helms
    R Terinde
    Breast Cancer Research, 3 (Suppl 1)
  • [44] The study of morphology and circulation of early embryo by three-dimensional ultrasound and power Doppler
    Kurjak, A
    Kupesic, S
    Banovic, I
    Hafner, T
    Kos, M
    JOURNAL OF PERINATAL MEDICINE, 1999, 27 (03) : 145 - 157
  • [45] THREE-DIMENSIONAL ULTRASOUND-GUIDED REAL-TIME MIDLINE EPIDURAL NEEDLE PLACEMENT WITH EPIGUIDE: A PROSPECTIVE FEASIBILITY STUDY
    Beigi, Parmida
    Malenfant, Paul
    Rasoulian, Abtin
    Rohling, Robert
    Dube, Alison
    Gunkay, Vit
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (01): : 375 - 379
  • [46] Ultrasonographer experience does not impact outcomes following ultrasound-guided embryo transfer
    Harris, Isiah D.
    Styer, Aaron K.
    Petrozza, John C.
    FERTILITY AND STERILITY, 2009, 92 (03) : 918 - 922
  • [47] A meta-analysis of ultrasound-guided versus clinical touch embryo transfer
    Buckett, WM
    FERTILITY AND STERILITY, 2003, 80 (04) : 1037 - 1041
  • [48] Ultrasound-guided embryo transfer: a meta-analysis of randomized controlled trials
    Sallam, HN
    Sadek, SS
    FERTILITY AND STERILITY, 2003, 80 (04) : 1042 - 1046
  • [49] Evaluation of the transvaginal ultrasound-guided intrauterine injection technique for embryo transfer in mares
    Gastal, MO
    Gastal, EL
    Rivera, AP
    Silva, LA
    THERIOGENOLOGY, 2002, 58 (2-4) : 725 - 728
  • [50] Ultrasound-guided embryo transfer - a special role in patients with certain uterine defects
    Kol, Shahar
    FERTILITY AND STERILITY, 2008, 89 (01) : 260 - 260