Three-dimensional ultrasound-guided embryo transfer: A preliminary study

被引:16
|
作者
Letterie, GS [1 ]
机构
[1] Virginia Mason Med Ctr, Ctr Fertil & Reprod Endocrinol, Seattle, WA 98101 USA
关键词
three-dimensional ultrasound; embryo transfer; in vitro fertilization;
D O I
10.1016/j.ajog.2005.02.044
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: Embryo transfer techniques have emerged Lis 1 of the most important variables during in vitro fertilization. Two-dimensional ultrasound guidance is an integral part of this procedure and a method to monitor catheter passage through the cervix into the endometrial cavity. Catheter placement may better be achieved with 3-dimensional monitoring to assess the relationship of the catheter tip to the uterine cavity. The purpose of this study was to compare the precision of catheter placement and position by 2- and 3-dimensional ultrasound. Study design: Twenty-four patients were studied. The cervix, Uterus, and endometrial cavity were prescreened in 2 dimensions at the midline in the longitudinal plane of the uterus. Embryo transfers were then performed Under 2-dimensional guidance. After satisfactory catheter placement and transfer of the embryos, the catheter was held in place for 60 to 120 seconds. During this interval, an automated, single sweep of the uterus and endometrial cavity was performed for net volume acquisition. All images were stored and retrospectively reviewed. Embryo transfer catheter placement with 2-dimensional Ultrasound guidance was then compared with the images obtained in 3 Simultaneous planes. Results: Visualization of the embryo catheter tip with 2-dimensional Ultrasound was achieved in all patients. These images suggested that the catheter was 2 cm from the uterine fundus and in the midline. Satisfactory 3-dimensional images for review and comparison were obtained in 21 of 24 patients. Three-dimensional ultrasound images confirmed placement and agreed with findings 9 of 2-dimensional ultrasound images in 17 of 21 patients. In 4 patients, the catheter tip on 3-dimensional Ultrasound was observed to be displaced either anteriorly or laterally from the ideal region as suggested by 2-dimensional ultrasound. In 1 case, the catheter tip on 3-dimensional Ultrasound was observed to be far laterally in the region of the uterine cornua. Conclusion: Two-dimensional ultrasound-guided embryo transfer Continues to be the standard for image-guided transfers. Data of the present Study Suggest that the precision of catheter tip placement and consequently embryo transfer may be improved with 3-dimensional imaging. Four of 21 patients Studied had catheter tip placement in a different and less-than-ideal area when Studied with 3-dimensional ultrasound. Three-dimensional imaging may provide an improvement in embryo transfer technique and have a positive impact oil overall pregnancy rates. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:1983 / 1987
页数:5
相关论文
共 50 条
  • [21] THREE-DIMENSIONAL ULTRASOUND GUIDANCE: THE NEW FRONTIER OF EMBRYO TRANSFER?
    Beebeejaun, Yusuf
    Sunkara, Sesh
    Sarris, Ippokratis
    Duffy, James M. N.
    FERTILITY AND STERILITY, 2020, 114 (03) : E249 - E249
  • [22] To study the efficacy of Transvaginal ultrasound-guided Embryo Transfer over Transabdominal ultrasound-guided Embryo Transfer in transfers with poor visibility due to obesity or marked retroversion
    Jha, B.
    Singh, P.
    HUMAN REPRODUCTION, 2023, 38
  • [23] Three-dimensional ultrasound-guided robotic needle placement: an experimental evacuation
    Boctor, Emad M.
    Choti, Michael A.
    Burdette, Everette C.
    Webster, Robert J., III
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2008, 4 (02): : 180 - 191
  • [24] The development and evaluation of a three-dimensional ultrasound-guided breast biopsy apparatus
    Surry, K
    Smith, WL
    Campbell, LJ
    Mills, GR
    Downey, DB
    Fenster, A
    MEDICAL IMAGE ANALYSIS, 2002, 6 (03) : 301 - 312
  • [25] Embryo transfer: ultrasound-guided versus clinical touch
    Kan, AKS
    Abdalla, HI
    Gafar, AH
    Nappi, L
    Ogunyemi, BO
    Thomas, A
    Ola-ojo, OO
    HUMAN REPRODUCTION, 1999, 14 (05) : 1259 - 1261
  • [26] Ultrasound-guided embryo transfer improves pregnancy rates
    Kolankaya, A.
    Enginsu, M. E.
    Camlibel, T. F.
    Sarikamis, B.
    Kurt, E.
    Yildiz, K.
    Hunerli, C.
    HUMAN REPRODUCTION, 2001, 16 : 155 - 156
  • [27] Novel Three-Dimensional Printed Simulators for Ultrasound-Guided Prenatal Diagnostic Procedures
    Keller, Nathan A.
    Neuwirth, Allison E.
    Jackson, Frank I.
    Kouba, Insaf
    Muscat, Jolene
    Bracero, Luis A.
    Blitz, Matthew J.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2025,
  • [28] Three-dimensional endoluminal ultrasound-guided interstitial brachytherapy in patients with anal cancer
    Christensen, A. F.
    Nielsen, M. Bachmann
    Engelholm, S. A.
    ACTA RADIOLOGICA, 2008, 49 (02) : 132 - 137
  • [29] Ultrasound-guided three-dimensional needle steering in biological tissue with curved surfaces
    Abayazid, Momen
    Moreira, Pedro
    Shahriari, Navid
    Patil, Sachin
    Alterovitz, Ron
    Misra, Sarthak
    MEDICAL ENGINEERING & PHYSICS, 2015, 37 (01) : 145 - 150
  • [30] Ultrasound-guided embryo transfer: a prospective randomized controlled trial
    Tang, OS
    Ng, EHY
    So, WWK
    Ho, PC
    HUMAN REPRODUCTION, 2001, 16 (11) : 2310 - 2315