An in-fiber Bragg grating sensor for contact force and stress measurements in articular joints

被引:28
作者
Dennison, Christopher R. [1 ]
Wild, Peter M. [1 ]
Wilson, David R. [2 ,3 ]
Gilbart, Michael K. [2 ,3 ]
机构
[1] Univ Victoria, Dept Mech Engn, Victoria, BC V8W 3P6, Canada
[2] Univ British Columbia, Dept Orthopaed, Vancouver, BC V5Z 1M9, Canada
[3] Univ British Columbia, Ctr Hip Hlth & Mobil, Vancouver, BC V5Z 1M9, Canada
关键词
fiber Bragg grating; articular joint; hip; stress; biomechanics; sensor; ACETABULAR LABRUM; PRESSURE SENSOR; OPTICAL-FIBERS; KNEE; HIP; TEMPERATURE; STRAIN; CONSEQUENCES; SENSITIVITY; MECHANICS;
D O I
10.1088/0957-0233/21/11/115803
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We present an in-fiber Bragg grating-based sensor (240 mu m diameter) for contact force/stress measurements in articular joints. The contact force sensor and another Bragg grating-based pressure sensor (400 mu m diameter) are used to conduct the first simultaneous measurements of contact force/stress and fluid pressure in intact cadaveric human hips. The contact force/stress sensor addresses limitations associated with stress-sensitive films, the current standard tools for contact measurements in joints, including cartilage modulus-dependent sensitivity of films and the necessity to remove biomechanically relevant anatomy to implant the films. Because stress-sensitive films require removal of anatomy, it has been impossible to validate the mechanical rationale underlying preventive or corrective surgeries, which repair these anatomies, by conducting simultaneous stress and pressure measurements in intact hips. Methods are presented to insert the Bragg grating-based sensors into the joint, while relevant anatomy is left largely intact. Sensor performance is predicted using numerical models and the predicted sensitivity is verified through experimental calibrations. Contact force/stress and pressure measurements in cadaveric joints exhibited repeatability. With further validation, the Bragg grating-based sensors could be used to study the currently unknown relationships between contact forces and pressures in both healthy and degenerated joints.
引用
收藏
页数:15
相关论文
共 60 条
[1]   Validation of finite element predictions of cartilage contact pressure in the human hip joint [J].
Anderson, Andrew E. ;
Ellis, Benjamin J. ;
Maas, Steve A. ;
Peters, Christopher L. ;
Weiss, Jeffrey A. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (05)
[2]  
[Anonymous], THEOR REF ANSYS ANSY
[3]  
*ANSYS INC, ANSYS US MAN ANSYS R, pCH13
[4]  
*ANSYS INCF, ANSYS STRUCT AN GUID, pCH1
[5]   Temperature and strain insensitive bending measurements with D-type fibre Bragg gratings [J].
Araújo, FM ;
Ferreira, LA ;
Santos, JL ;
Farahi, F .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (07) :829-833
[6]   Measuring contact area, force, and pressure for bioengineering applications: Using Fuji Film and TekScan systems [J].
Bachus, Kent N. ;
DeMarco, Alyssa L. ;
Judd, Kyle T. ;
Horwitz, Daniel S. ;
Brodke, Darrel S. .
MEDICAL ENGINEERING & PHYSICS, 2006, 28 (05) :483-488
[7]   The relationship of the compressive modulus of articular cartilage with its deformation response to cyclic loading: does cartilage optimize its modulus so as to minimize the strains arising in it due to the prevalent loading regime? [J].
Barker, MK ;
Seedhom, BB .
RHEUMATOLOGY, 2001, 40 (03) :274-284
[8]   Effect of Calibration Method on Tekscan Sensor Accuracy [J].
Brimacombe, Jill M. ;
Wilson, David R. ;
Hodgson, Antony J. ;
Ho, Karen C. T. ;
Anglin, Carolyn .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (03)
[9]   Assessment of common hyperelastic constitutive equations for describing normal and osteoarthritic articular cartilage [J].
Brown, C. P. ;
Nguyen, T. C. ;
Moody, H. R. ;
Crawford, R. W. ;
Oloyede, A. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2009, 223 (H6) :643-652
[10]  
Bullough P, 1973, J Bone Joint Surg Br, V55, P746