Antibody fragment recognition layers for surface plasmon resonance biosensing: a parametric study

被引:0
|
作者
Magalhaes, Andre [1 ,2 ]
Bordeira, Sandro [1 ]
Almeida, Ana Cristina [1 ]
Fontes, Vanessa [1 ]
Leite Costa, Maria Joao [1 ]
Fonseca, Luis P. [2 ]
da Fonseca, Joao Garcia [1 ]
机构
[1] Biosurfit SA, Ed ICAT, Campus Fac Ciencias, P-1749016 Lisbon, Portugal
[2] Inst Super Tecn, P-1049001 Lisbon, Portugal
来源
ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS VII | 2009年 / 7169卷
关键词
Immunosensor; Surface plasmon resonance; Antibody fragments; Non-specific binding; C-reactive protein;
D O I
10.1117/12.808820
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A comparative study is reported regarding the use of two different surface plasmon resonance (SPR) biosensors, a homemade SPR grating biosensor and a reference prism coupled biosensor, to perform quantification of C-reactive protein (CRP) in human blood serum. Surface functionalization was conducted using anti-CRP fragments immobilized directly on gold. Adsorption time optimization for the antibody fragments monolayer, non-specific binding (NSB) resistance evaluation and CRP detection were conducted, with better results achieved by the grating biosensor on all topics, namely less functionalization time, higher resistance to NSB and wider CRP dynamic concentration range. A study regarding comparison between continuous flow and surface coating immobilization is also reported in this work. We have shown that surface coating immobilization achieves similar NSB resistance and CRP detection results, allowing a 75% assay cost reduction by lower solution volume requirement. Results suggest that the coating immobilization technique is the best suited to be used in further studies in order to obtain a viable immunosensor for CRP and other biomarkers detection in complex biological fluids.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Biosensing applications of surface plasmon resonance-based Biacore technology
    Gopinath, Subash C. B.
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 150 (02): : 722 - 733
  • [32] Surface Plasmon Resonance Biosensing via Differential Spectral Phase Interferometry
    Ng, Siu-Pang
    Wu, Chi-Man Lawrence
    Wu, Shu-Yuen
    Ho, Ho-Pui
    Kong, Siu-Kai
    PLASMONICS IN BIOLOGY AND MEDICINE VIII, 2011, 7911
  • [33] Use of a low refractive index prism in surface plasmon resonance biosensing
    Gupta, Gaurav
    Sugimoto, Mitsunori
    Matsui, Yoshikazu
    Kondoh, Jun
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 130 (02) : 689 - 695
  • [34] Affinity profiling of monoclonal antibody and antibody-drug-conjugate preparations by coupled liquid chromatography-surface plasmon resonance biosensing
    Dina Lakayan
    Rob Haselberg
    Rabah Gahoual
    Govert W. Somsen
    Jeroen Kool
    Analytical and Bioanalytical Chemistry, 2018, 410 : 7837 - 7848
  • [35] A symmetrical optical waveguide based surface plasmon resonance biosensing system
    Shi, Heng
    Liu, Zhiyi
    Wang, Xiaoxiao
    Guo, Jun
    Liu, Le
    Luo, Lin
    Guo, Jihua
    Ma, Hui
    Sun, Shuqing
    He, Yonghong
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 185 : 91 - 96
  • [36] Surface plasmon resonance biosensors as a tool in antibody engineering
    Alfthan, K
    BIOSENSORS & BIOELECTRONICS, 1998, 13 (06) : 653 - 663
  • [37] Recent Advancements in Aptamer-Based Surface Plasmon Resonance Biosensing Strategies
    Chang, Chia-Chen
    BIOSENSORS-BASEL, 2021, 11 (07):
  • [38] Gold Albumin Sandwich Structures for Enhanced Biosensing Using Surface Plasmon Resonance
    Rueger, Fabian
    Keusgen, Michael
    Vornicescu, Doru
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2021, 218 (13):
  • [39] Fragment Screening Using Surface Plasmon Resonance Optical Biosensor Technology
    Miura, Takaaki
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2010, 130 (03): : 341 - 348
  • [40] Study on Snake Venom Protein-Antibody Interaction by Surface Plasmon Resonance Spectroscopy
    Choudhury, Subhankar N.
    Konwar, Barlina
    Kaur, Simran
    Doley, Robin
    Mondal, Biplob
    PHOTONIC SENSORS, 2018, 8 (03) : 193 - 202