Volumetric properties and phase behavior of sulfur dioxide, carbon disulfide and oxygen in high-pressure carbon dioxide fluid

被引:6
作者
Commodore, Jerry A. [1 ]
Deering, Connor E. [1 ]
Marriott, Robert A. [1 ]
机构
[1] Univ Calgary, Dept Chem, 2500 Univ Dr NW, Calgary, AB T2N 1N4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Acid gas injection; Apparent molar volume; Carbon capture and sequestration; Fluctuation solution theory; Reduced helmholtz mixing parameters; Carbon dioxide density; CO2; STATE; GAS; EQUATION; LIQUID; TEMPERATURE; EQUILIBRIUM; IMPURITIES; MIXTURES; STORAGE;
D O I
10.1016/j.fluid.2018.08.012
中图分类号
O414.1 [热力学];
学科分类号
摘要
Acid gas re-injection or carbon capture and storage are two technologies now implemented for management of produced CO2 or reducing the industrial emission of CO2. For both technologies, impurities such as H2O, H2S, O-2, and SO2 can find a way into a CO2 injectate stream. In addition to unwanted reactions, these impurities can alter the phase behavior and volumetric properties of the injectate stream. Measuring accurate densities associated with mixing various impurities and CO2 fluid is one method to optimize mixing coefficients for calculating reliable phase behavior and chemical activities for these systems. In this work, the volumetric influence and/or phase behavior of SO2, CS2, or O-2 impurities in a dense CO2 phase were studied through high-precision density measurements. Densities of the CO2 mixtures were measured with a custom vibrating tube densimeter with an average uncertainty of +/- 0.07 kg m(-3) for temperatures of T = 50 to 125 degrees C and pressures at p <= 35 MPa. The densities were used in calculating the apparent molar volumes, which were subsequently used to (i) calibrate or verify mixing coefficients for reference quality reduced Helmholtz energy equations-of-state, and (ii) provide a fitted equation based on fluctuation solution theory which can be used to calculate fugacity coefficients and partial molar volumes of CS2 at infinite dilution. Validating our optimized mixing coefficients for the CO2 + SO2 mixture showed more reliable vapor-liquid equilibrium phase behavior when compared to those previously estimated in the literature. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:30 / 39
页数:10
相关论文
共 27 条
[1]   Effect of impurities in captured CO2 on liquid-vapor equilibrium [J].
Ahmad, Mohammad ;
Gernert, Johannes ;
Wilbers, Erwin .
FLUID PHASE EQUILIBRIA, 2014, 363 :149-155
[2]   Chemical and Hydrodynamic Mechanisms for Long-Term Geological Carbon Storage [J].
Altman, Susan J. ;
Aminzadeh, Behdad ;
Balhoff, Matthew T. ;
Bennett, Philip C. ;
Bryant, Steven L. ;
Cardenas, M. Bayani ;
Chaudhary, Kuldeep ;
Cygan, Randall T. ;
Deng, Wen ;
Dewers, Thomas ;
DiCarlo, David A. ;
Eichhubl, Peter ;
Hesse, Marc A. ;
Huh, Chun ;
Matteo, Edward N. ;
Mehmani, Yashar ;
Tenney, Craig M. ;
Yoon, Hongkyu .
JOURNAL OF PHYSICAL CHEMISTRY C, 2014, 118 (28) :15103-15113
[3]  
Bachu S., 2004, INT C GREENH GAS CON, P1
[4]  
Bluemcke A., 1887, ANN PHYS-LEIPZIG, V34, P10
[5]  
Carroll J. J., 2002, J CAN PET TECHNOL, V41, P1
[6]  
Deering C. E., 2015, THESIS
[7]   The Volumetric Properties of Carbonyl Sulfide and Carbon Dioxide Mixtures from T=322 to 393 K and p=2.5 to 35 MPa: Application to COS Hydrolysis in Subsurface Injectate Streams [J].
Deering, Connor E. ;
Saunders, Matthew J. ;
Commodore, Jerry A. ;
Marriott, Robert A. .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2016, 61 (03) :1341-1347
[8]   The partial molar volumes for water dissolved in high-pressure carbon dioxide from T = (318.28 to 369.40) K and pressures to p=35 MPa [J].
Deering, Connor E. ;
Cairns, Edward C. ;
McIsaac, Jay D. ;
Read, Andrew S. ;
Marriott, Robert A. .
JOURNAL OF CHEMICAL THERMODYNAMICS, 2016, 93 :337-346
[9]   GAS-LIQUID EQUILIBRIUM OF OXYGEN-CARBON DIOXIDE SYSTEM [J].
FREDENSLUND, A ;
SATHER, GA .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 1970, 15 (01) :17-+
[10]   Techno-economic analysis of CO2 conditioning processes in a coal based oxy-combustion power plant [J].
Fu, Chao ;
Gundersen, Truls .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2012, 9 :419-427