Improvement of the piecewise direct standardisation procedure for the transfer of NIR spectra for multivariate calibration

被引:134
作者
Bouveresse, E [1 ]
Massart, DL [1 ]
机构
[1] FREE UNIV BRUSSELS, INST PHARMACEUT, B-1090 BRUSSELS, BELGIUM
关键词
near-infrared spectroscopy; multivariate calibration; calibration transfer; piecewise direct standardisation;
D O I
10.1016/0169-7439(95)00074-7
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Standardisation of near-infrared spectrometric instruments using the piecewise direct standardisation method is studied. Two important steps of this method, namely the selection of the subset samples and the determination of the local optimal number of principal components, can yield artefacts in the transferred spectra, if they are not carefully performed. Three different algorithms are tested on two different data sets in order to study the subset selection, and a method based on the prediction of an independent test sample is proposed in order to detect the artefacts due to bad local rank determinations. Improvements of the standardisation procedures were obtained, particularly when low numbers of standardisation samples were included in the subset.
引用
收藏
页码:201 / 213
页数:13
相关论文
共 15 条
  • [1] APPLICATION OF NONLINEAR-REGRESSION FUNCTIONS FOR THE MODELING OF RETENTION IN REVERSED-PHASE LC
    BOURGUIGNON, B
    DEAGUIAR, PF
    THORRE, K
    MASSART, DL
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1994, 32 (04) : 144 - 152
  • [2] CALIBRATION TRANSFER ACROSS NEAR-INFRARED SPECTROMETRIC INSTRUMENTS USING SHENKS ALGORITHM - EFFECTS OF DIFFERENT STANDARDIZATION SAMPLES
    BOUVERESSE, E
    MASSART, DL
    DARDENNE, P
    [J]. ANALYTICA CHIMICA ACTA, 1994, 297 (03) : 405 - 416
  • [3] MODIFIED ALGORITHM FOR STANDARDIZATION OF NEAR-INFRARED SPECTROMETRIC INSTRUMENTS
    BOUVERESSE, E
    MASSART, DL
    DARDENNE, P
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (08) : 1381 - 1389
  • [4] MULTIVARIATE CALIBRATION STANDARDIZATION
    DENOORD, OE
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1994, 25 (02) : 85 - 97
  • [5] DENOORD OE, 1994, INT CHEM RES M VELDH
  • [6] FORINA M, 1992, ELLIS HOR S, P91
  • [7] TRANSFER OF CALIBRATION FUNCTION IN NEAR-INFRARED SPECTROSCOPY
    FORINA, M
    DRAVA, G
    ARMANINO, C
    BOGGIA, R
    LANTERI, S
    LEARDI, R
    CORTI, P
    CONTI, P
    GIANGIACOMO, R
    GALLIENA, C
    BIGONI, R
    QUARTARI, I
    SERRA, C
    FERRI, D
    LEONI, O
    LAZZERI, L
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1995, 27 (02) : 189 - 203
  • [8] COMPUTER AIDED DESIGN OF EXPERIMENTS
    KENNARD, RW
    STONE, LA
    [J]. TECHNOMETRICS, 1969, 11 (01) : 137 - &
  • [9] OSBORNE BG, 1983, J FOOD TECHNOL, V18, P453, DOI 10.1177/0047117804048489
  • [10] CALIBRATION TRANSFER BETWEEN NEAR-INFRARED REFLECTANCE SPECTROPHOTOMETERS
    SHENK, JS
    WESTERHAUS, MO
    TEMPLETON, WC
    [J]. CROP SCIENCE, 1985, 25 (01) : 159 - 161