Intraoperative tap test for coronal syndesmotic instability: A cadaveric study

被引:4
|
作者
Netto, Cesar de Cesar [1 ,2 ]
Pinto, Martim [2 ]
Roberts, Lauren [1 ]
Lee, Sung Ro [2 ]
Roney, Andrew R. [1 ]
Naranje, Sameer [2 ]
Godoy-Santos, Alexandre Leme [3 ]
Shah, Ashish [2 ]
机构
[1] Hosp Special Surg, Dept Foot & Ankle Orthoped, 535 East 70th St, New York, NY 10021 USA
[2] UAB, Dept Orthoped, Birmingham, AL 35294 USA
[3] Univ Sao Paulo, Dept Orthoped, Sao Paulo, SP, Brazil
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2018年 / 49卷 / 10期
关键词
Ankle fracture; Syndesmotic injury; Syndesmotic instability; Cotton test; Malleolar fracture; DISTAL TIBIOFIBULAR SYNDESMOSIS; ANKLE FRACTURES; CLINICAL-TESTS; INJURY; DIAGNOSIS; FIXATION; BIMALLEOLAR; SCREW; MRI;
D O I
10.1016/j.injury.2018.08.005
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Precise diagnosis of distal tibiofibular syndesmotic injury is challenging, and a gold standard diagnostic test has still not been established. Tibiofibular clear space identified on radiographic imaging is considered the most reliable indicator of the injury. The Cotton test is the most widely used intraoperative technique to evaluate the syndesmotic integrity although it has its limitations. We advocate for a novel intra operative test using a 3.5 mm blunt cortical tap. Methods: Tibiofibular clear space was assessed in nine cadaveric specimens using three sequential fluoroscopic images. The first image was taken prior to the application of the tap test (intact, non-stressed). Then, a 2.5 mm hole was drilled distally on the lateral fibula, and a 3.5 mm cortical tap was then threaded in the hole. The tap test involved gradually advancing the blunt tip against the lateral tibia, providing a tibiofibular separation force (intact, stressed). This same stress was then applied after all syndesmotic ligaments were released (injured, stressed). Measurements were compared by one-way ANOVA and paired Student's t-test. Intra and inter-observer agreements were evaluated by intraclass correlation coefficient (ICC). P-values <.05 were considered significant. Results: We found excellent intra-observer (0.97) and inter-observer (0.98) agreement following the imaging assessment. Significant differences were found in the paired comparison between the groups (p <.05). When using an absolute value for TFCS >6 mm as diagnostic for coronal syndesmotic instability, the tap test demonstrated a 96.3% sensitivity and specificity, a 96.3% PPV and NPV and a 96.3% accuracy in diagnosing coronal syndesmotic instability. Conclusions: Our cadaveric study demonstrated that this novel coronal syndesmotic instability test using a 3.5 mm blunt cortical tap is a simple, accurate and reliable technique able to demonstrate significant differences in the tibiofibular clear space when injury was present. It could represent a more controlled and stable alternative to the most used Cotton test. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1758 / 1762
页数:5
相关论文
共 50 条
  • [21] Accuracy of Anterolateral Drawer Test in Lateral Ankle Instability: A Cadaveric Study
    Phisitkul, Phinit
    Chaichankul, Chaisiri
    Sripongsai, Ratthapol
    Prasitdamrong, Ittipol
    Tengtrakulcharoen, Pannipa
    Suarchawaratana, Siripim
    FOOT & ANKLE INTERNATIONAL, 2009, 30 (07) : 690 - 695
  • [22] Diagnostic value of intraoperative tap test for acute deltoid ligament injury
    Bi, Chun
    Kong, Dechao
    Lin, Jian
    Wang, Qiugen
    Wu, Kai
    Huang, Jianhua
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2021, 47 (04) : 921 - 928
  • [23] Biomechanics comparison between endobutton fixation and syndesmotic screw fixation for syndesmotic injury ankle fracture; a finite element analysis and cadaveric validation study
    Meekaew, Papangkorn
    Paholpak, Permsak
    Wisanuyotin, Taweechok
    Sirichativapee, Winai
    Sirichativapee, Wilasinee
    Kosuwon, Weerachai
    Kasai, Yuichi
    JOURNAL OF ORTHOPAEDICS, 2022, 34 : 207 - 214
  • [24] Consideration of medial anatomical structures at risk when placing quadricortical syndesmotic fixation: A cadaveric study
    Kaiser, Philip B.
    Riedel, Matthew D.
    Qudsi, Rameez
    Watkins, Ian T.
    Ghorbanhoseini, Mohammad
    Nazarian, Ara
    Kwon, John Y.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (02): : 527 - 531
  • [25] Influence of unstable ankle fracture (type Weber C), osteosynthesis and syndesmotic transfixation on position of fibula in tibiofibular notch: a cadaveric study
    Privalov, Maxim
    Swartman, Benedict
    Beisemann, Nils
    El Barbari, Jan
    Franke, Jochen
    Grutzner, Paul Alfred
    Vetter, Sven
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (02) : 1445 - 1452
  • [26] Cadaveric Diagnostic Study of Subtle Syndesmotic Instability Using a 3-Dimensional Weight-Bearing CT Distance Mapping Algorithm
    Netto, Cesar de Cesar
    Mansur, Nacime Salomao Barbachan
    Talaski, Grayson
    Behrens, Andrew
    de Carvalho, Kepler Alencar Mendes
    Dibbern, Kevin
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2025, 107 (04) : 397 - 407
  • [27] The Effect of Suture-Button Fixation on Simulated Syndesmotic Malreduction: A Cadaveric Study
    Westermann, Robert W.
    Rungprai, Chamnanni
    Goetz, Jessica E.
    Femino, John
    Amendola, Annunziato
    Phisitkul, Phinit
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (20) : 1732 - 1738
  • [28] Intraoperative Torque Test to Assess Syndesmosis Instability
    Gosselin-Papadopoulos, Nayla
    Hebert-Davies, Jonah
    Laflamme, G. Yves
    Beausejour, Marie
    Menard, Jeremie
    Leduc, Stephane
    Nault, Marie-Lyne
    FOOT & ANKLE INTERNATIONAL, 2019, 40 (04) : 408 - 413
  • [29] Does Proximal Placement of the Syndesmotic Reduction Clamp Affect the Optimal Position for the Medial Tine? A Cadaveric Pilot Study
    Rushing, Calvin J.
    Spinner, Steven M.
    Armstrong, Albert V., Jr.
    JOURNAL OF FOOT & ANKLE SURGERY, 2022, 61 (01) : 3 - 6
  • [30] Diagnostic value of intraoperative tap test for acute deltoid ligament injury
    Chun Bi
    Dechao Kong
    Jian Lin
    Qiugen Wang
    Kai Wu
    Jianhua Huang
    European Journal of Trauma and Emergency Surgery, 2021, 47 : 921 - 928