Recent strategies to minimise fouling in electrochemical detection systems

被引:231
作者
Hanssen, Benjamin L. [1 ]
Siraj, Shajahan [1 ]
Wong, Danny K. Y. [1 ]
机构
[1] Macquarie Univ, Dept Chem & Biomol Sci, Sydney, NSW 2109, Australia
关键词
chemical fouling; fouling during neurotransmitter detection; strategies for minimising electrode fouling; BORON-DOPED DIAMOND; GLASSY-CARBON ELECTRODE; ELECTROCATALYTIC OXIDATION; SELECTIVE DETERMINATION; AMPEROMETRIC DETECTION; SURFACE-CHEMISTRY; GOLD ELECTRODE; VOLTAMMETRIC DETECTION; FIBER MICROELECTRODE; COMPOSITE ELECTRODE;
D O I
10.1515/revac-2015-0008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrode fouling is a phenomenon that can severely affect the analytical characteristics of a technique or a sensor, such as sensitivity, detection limit, reproducibility, and overall reliability. Electrode fouling generally involves the passivation of an electrode surface by a fouling agent that forms an increasingly impermeable layer on the electrode, inhibiting the direct contact of an analyte of interest with the electrode surface for electron transfer. Some potential fouling agents include proteins, phenols, amino acids, neurotransmitters, and other biological molecules. Various antifouling strategies have been reported to reduce or eliminate electrode fouling. Most antifouling strategies exploit a protective layer or barrier on an electrode substrate to prevent the fouling agent from reaching the electrode surface. Although such strategies can be quite effective, they are inappropriate for systems in which the analyte itself is also the fouling agent. In such cases, other strategies must be used, including electrode surface modification and electrochemical activation. In this review, recent strategies to minimise and efforts to overcome electrode fouling across a diverse range of analytes and fouling agents will be presented.
引用
收藏
页码:1 / 28
页数:28
相关论文
共 110 条
[1]   Steady-State Electrochemical Determination of Lipidic Nanotube Diameter Utilizing an Artificial Cell Model [J].
Adams, Kelly L. ;
Engelbrektsson, Johan ;
Voinova, Marina ;
Zhang, Bo ;
Eves, Daniel J. ;
Karlsson, Roger ;
Heien, Michael L. ;
Cans, Ann-Sofie ;
Ewing, Andrew G. .
ANALYTICAL CHEMISTRY, 2010, 82 (03) :1020-1026
[2]   Wireless Instantaneous Neurotransmitter Concentration System-based amperometric detection of dopamine, adenosine, and glutamate for intraoperative neurochemical monitoring Laboratory investigation [J].
Agnesi, Filippo ;
Tye, Susannah J. ;
Bledsoe, Jonathan M. ;
Griessenauer, Christoph J. ;
Kimble, Christopher J. ;
Sieck, Gary C. ;
Bennet, Kevin E. ;
Garris, Paul A. ;
Blaha, Charles D. ;
Lee, Kendall H. .
JOURNAL OF NEUROSURGERY, 2009, 111 (04) :701-711
[3]   Electron transfer mechanism of cytochrome c at graphene electrode [J].
Alwarappan, Subbiah ;
Joshi, Rakesh K. ;
Ram, Manoj K. ;
Kumar, Ashok .
APPLIED PHYSICS LETTERS, 2010, 96 (26)
[4]   Anodic oxidation of chlorophenols in micelles and microemulsions on glassy carbon electrode: the medium effect on electroanalysis and electrochemical detoxification [J].
Anandhakumar, S. ;
Chandrasekaran, M. ;
Noel, M. .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (02) :303-310
[5]   Stabilised Biosensing Using Needle-Based Recess Electrodes [J].
Anastasova, Salzitsa ;
Spehar-Deleze, Anna-Maria ;
Bickham, Dale ;
Uebel, Patrick ;
Schmidt, Markus ;
Russell, Philip ;
Vadgama, Pankaj .
ELECTROANALYSIS, 2012, 24 (03) :529-538
[6]   The analysis of estrogenic compounds by flow injection analysis with amperometric detection using a boron-doped diamond electrode [J].
Brocenschi, Ricardo F. ;
Rocha-Filho, Romeu C. ;
Duran, Boris ;
Swain, Greg M. .
TALANTA, 2014, 126 :12-19
[7]   Nanoporous gold for amperometric detection of amino-containing compounds [J].
Bui Thi Phuong Quynh ;
Byun, Ji Young ;
Kim, Sang Hoon .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 193 :1-9
[8]   Electrocatalytic Oxidation of Some Hydrazine Compounds at Glassy Carbon Electrode Modified with Co-Gluconate Complex [J].
Casella, Innocenzo G. ;
Contursi, Michela .
ELECTROANALYSIS, 2012, 24 (04) :752-758
[9]   A self-polishing platinum ring voltammetric sensor and its application to complex media [J].
Cavanillas, Santiago ;
Winquist, Fredrik ;
Eriksson, Mats .
ANALYTICA CHIMICA ACTA, 2015, 859 :29-36
[10]   Minimizing Fouling at Hydrogenated Conical-Tip Carbon Electrodes during Dopamine Detection in Vivo [J].
Chandra, Shaneel ;
Miller, Anthony D. ;
Bendavid, Avi ;
Martin, Philip J. ;
Wong, Danny K. Y. .
ANALYTICAL CHEMISTRY, 2014, 86 (05) :2443-2450