A hybrid renewable system based on wind and solar energy coupled with an electrical storage: Dynamic simulation and economic assessment

被引:112
作者
Buonomano, Annamaria [1 ]
Calise, Francesco [1 ]
d'Accadia, Massimo Dentice [1 ]
Vicidomini, Maria [1 ]
机构
[1] Univ Naples Federico II, Dept Ind Engn, Ple Tecchio 80, I-80125 Naples, Italy
关键词
Dynamic simulation; Energy storage; Wind and solar energy; HYDROGEN-PRODUCTION; PV; TURBINE; OPTIMIZATION; DESIGN; FUELS; AREA;
D O I
10.1016/j.energy.2018.05.006
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work presents a thermo-economic simulation model of a hybrid renewable power plant based on wind turbine and photovoltaic technologies, coupled to an energy storage system. The total plant capacity is 200 kW (190 kW and 10 kW, for photovoltaic and wind turbine, respectively), whereas the energy storage capacity is 400 kWh. Aim of this work is to design a renewable power plant showing limited fluctuations (with respect to the ones typically achieved in case of solar systems) with marginal amounts of electricity purchased or sold to the grid, maximizing the electricity self-consumption. The thermo-economic model, developed in TRNSYS environment, allows one to determine the best system configuration and maximize the economic profitability by considering the time-dependent tariffs applied to the electricity exchanged with the grid and the possibility to store electricity. Different system layouts with or without the storage system and for different users are considered. Results show negative profit indexes of the layouts including the storage system (-0.27 in the worst case vs. 0.61 in the best case without the storage), due to its lower efficiency and its higher capital cost, although a remarkable reduction of the operating costs and an enhancing of the self-consumed energy. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:174 / 189
页数:16
相关论文
共 33 条
[1]   Use of Hybrid PV and Wind Turbine - Grid Connected System in a Local Emirati Home in Dubai-UAE [J].
Abu-Hijleh, Bassam .
3RD INTERNATIONAL CONFERENCE ON POWER AND ENERGY SYSTEMS ENGINEERING, CPESE 2016, 2016, 100 :463-468
[2]  
Agbossou K, 2005, IEEE IND APPLIC SOC, P2932
[3]   Minimizing the Lead-Acid Battery Bank Capacity through a Solar PV - Wind Turbine Hybrid System for a high-altitude village in the Nepal Himalayas [J].
Alex, Zahnd ;
Clark, Angel ;
Cheung, Wendy ;
Zou, Linda ;
Kleissl, Jan .
2013 ISES SOLAR WORLD CONGRESS, 2014, 57 :1516-+
[4]  
[Anonymous], 2014, PROCEDIA ENV SCI, DOI DOI 10.1016/J.PROENV.2014.11.032
[5]  
[Anonymous], 2006, TRNSYS: a transient system simulation program
[6]   An overview of high voltage conversion ratio DC-DC converter configurations used in DC micro-grid architectures [J].
Arunkumari, T. ;
Indragandhi, V. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 77 :670-687
[7]  
Authority NE, 2018, AUT REG EN RET AMB
[8]   Dynamic modeling of gravity energy storage coupled with a PV energy plant [J].
Berrada, Asmae ;
Loudiyi, Khalid ;
Garde, Raquel .
ENERGY, 2017, 134 :323-335
[9]   Adsorption chiller operation by recovering low-temperature heat from building integrated photovoltaic thermal collectors: Modelling and simulation [J].
Buonomano, Annamaria ;
Calise, Francesco ;
Palombo, Adolfo ;
Vicidomini, Maria .
ENERGY CONVERSION AND MANAGEMENT, 2017, 149 :1019-1036
[10]   Energy and economic analysis of geothermal-solar trigeneration systems: A case study for a hotel building in Ischia [J].
Buonomano, Annamaria ;
Calise, Francesco ;
Palombo, Adolfo ;
Vicidomini, Maria .
APPLIED ENERGY, 2015, 138 :224-241