Intelligent gamma-ray spectroscopy using 3D position-sensitive detectors

被引:0
作者
Lehner, CE [1 ]
He, Z [1 ]
Knoll, GF [1 ]
机构
[1] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
来源
2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3 | 2003年
关键词
gamma-ray detector; intelligent spectroscopy; position-sensitive detectors; three-Compton reconstruction;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The performance of gamma-ray spectrometers at high energies (several MeV) can be greatly improved through intelligent spectroscopic analysis if spatial information is obtained for each energy deposition. In position-sensitive detectors, the energy and three-dimensional position of each interaction in the detector are determined. Recognizing the signatures of multiple interactions in the detector can help to reconstruct the energies of the initial gamma rays even when the full energies are not deposited. We present the results of a simulation study for 2.6 MeV gamma rays incident upon a 6-cm(3) CdZnTe detector using two reconstruction methods: high efficiency intelligent spectroscopy (HEIS) in which the peak-to-total ratio is greatly improved relative to traditional spectroscopy while maintaining almost the same intrinsic peak efficiency; and peak-only intelligent spectroscopy (POIS) in which the peak-to-total ratio can approach 0.9, assuming realistic values for energy resolution. Although POIS reduces the intrinsic peak efficiency, it will significantly improve the signal-to-noise ratio for many measurements. The predicted performance is unprecedented for a detector of such small volume and illustrates the gains that can be expected by exploiting 3-D information.
引用
收藏
页码:411 / 415
页数:5
相关论文
共 5 条
[1]   Evaluation of a Compton scattering camera using 3-D position sensitive CdZnTe detectors [J].
Du, YF ;
He, Z ;
Knoll, GF ;
Wehe, DK ;
Li, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 457 (1-2) :203-211
[2]   3-D position sensitive CdZnTe gamma-ray spectrometers [J].
He, Z ;
Li, W ;
Knoll, GF ;
Wehe, DK ;
Berry, J ;
Stahle, CM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3) :173-178
[3]  
KROEGER RA, 2001, NUCL SCI S, V1, P68
[4]  
RAWOOLSULLIVAN MW, 2001, NUCL SCI S, V1, P389
[5]   HPGe Compton suppression using pulse shape analysis [J].
Schmid, GJ ;
Beckedahl, D ;
Blair, JJ ;
Friensehner, A ;
Kammeraad, JE .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3) :368-372