Constructing a three-dimensional electrical model of a living cochlear implant user's cochlea

被引:35
|
作者
Malherbe, T. K. [1 ]
Hanekom, T. [1 ]
Hanekom, J. J. [1 ]
机构
[1] Univ Pretoria, Dept Elect Elect & Comp Engn, Bioengn Grp, Lynnwood Rd, ZA-0002 Pretoria, Gauteng, South Africa
基金
新加坡国家研究基金会;
关键词
cochlear implant; subject specific; fem; volume conduction model; neural excitation; skull model; FINITE-ELEMENT MODEL; NEURAL EXCITATION; STIMULATION; POTENTIALS; PATTERNS; ANATOMY; FIELDS; TISSUE; BRAIN; DEPTH;
D O I
10.1002/cnm.2751
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BackgroundHearing performance varies greatly among users of cochlear implants. Current three-dimensional cochlear models that predict the electrical fields inside a stimulated cochlea and their effect on neural excitation are generally based on a generic human or guinea pig cochlear shape that does not take inter-user morphological variations into account. This precludes prediction of user-specific performance. AimsThe aim of this study is to develop a model of the implanted cochlea of a specific living human individual and to assess if the inclusion of morphological variations in cochlear models affects predicted outcomes significantly. MethodsFive three-dimensional electric volume conduction models of the implanted cochleae of individual living users were constructed from standard CT scan data. These models were embedded in head models that include monopolar return electrodes in accurate anatomic positions. Potential distributions and neural excitation patterns were predicted for each of the models. ResultsModeled potential distributions and neural excitation profiles (threshold amplitudes, center frequencies, and bandwidths) are affected by user-specific cochlear morphology and electrode placement within the cochlea. ConclusionsThis work suggests that the use of user-specific models is indicated when more detailed analysis is required than what is available from generic models. Copyright (c) 2015 John Wiley & Sons, Ltd.
引用
收藏
页数:23
相关论文
共 50 条
  • [41] Cochlear implant in a patient with Mondini's deformity of the cochlea: pilot - patient in Pakistan
    Qadeer, Sadaf
    Junaid, Montasir
    Sobani, Zainul Abedeen
    Nadeem, Naila
    Awan, Mohammad Sohail
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2013, 63 (07) : 913 - 915
  • [42] `Inverse problem' solved for a three-dimensional model of the cochlea. I. Analysis
    de, Boer, Egbert
    Journal of the Acoustical Society of America, 1995, 98 (2 pt 1):
  • [43] Toward three-dimensional analysis of cochlear structure
    Steele, CR
    ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 1999, 61 (05): : 238 - 251
  • [44] A mimic osseointegrated implant model for three-dimensional finite element analysis
    Akagawa, Y
    Sato, Y
    Teixeira, ER
    Shindoi, N
    Wadamoto, M
    JOURNAL OF ORAL REHABILITATION, 2003, 30 (01) : 41 - 45
  • [45] Three-Dimensional Surface Reconstruction of the Human Cochlear Nucleus: Implications for Auditory Brain Stem Implant Design
    Tarabichi, Osama
    Kanumuri, Vivek V.
    Klug, Julian
    Vachicouras, Nicolas
    Duarte, Maria J.
    Epprecht, Lorenz
    Kozin, Elliott D.
    Reinshagen, Katherine
    Lacour, Stephanie P.
    Brown, M. Christian
    Lee, Daniel J.
    JOURNAL OF NEUROLOGICAL SURGERY PART B-SKULL BASE, 2020, 81 (02) : 114 - 120
  • [46] Cochlear implant-related three-dimensional characteristics determined by micro-computed tomography reconstruction
    Ni, Yusu
    Dai, Peidong
    Dai, Chunfu
    Li, Huawei
    CLINICAL ANATOMY, 2017, 30 (01) : 39 - 43
  • [47] Heat transfer analysis in an uncoiled model of the cochlea during magnetic cochlear implant surgery
    Esmailie, Fateme
    Francoeur, Mathieu
    Ameel, Tim
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 154
  • [48] The three-dimensional fibrillar arrangement of the basilar membrane in the mouse cochlea
    Mikuni, H
    Fukuda, S
    Kucuk, B
    Inuyama, Y
    Ushiki, T
    Abe, K
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 1995, 252 (08) : 495 - 498
  • [49] Three-dimensional modeling of the cochlea by use of an arc fitting approach
    Schurzig, Daniel
    Lexow, G. Jakob
    Majdani, Omid
    Lenarz, Thomas
    Rau, Thomas S.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2016, 19 (16) : 1785 - 1799
  • [50] Three-dimensional current flow in a large-scale model of the cochlea and the mechanism of amplification of sound
    Mistrik, Pavel
    Mullaley, Chris
    Mammano, Fabio
    Ashmore, Jonathan
    JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2009, 6 (32) : 279 - 291