Novel potentiometric sensors for determination of ondansetron hydrochloride in pure and dosage form

被引:7
作者
Abass, Amina M. [1 ]
Alabdullah, Sahar S. M. [1 ,2 ]
Hassan, Omar Salih [3 ]
Ahmed, Ahmed [1 ]
机构
[1] Al Nahrain Univ, Coll Sci, Dept Chem, Baghdad, Al Jaderia, Iraq
[2] Univ Leicester, Mat Ctr, Sch Chem, Leicester LE1 7RH, Leics, England
[3] Tikrit Univ, Coll Educ Pure Sci, Dept Chem, Tikrit, Iraq
关键词
MEMBRANE; CONSTRUCTION; FORMULATION; ELECTRODES; PLASMA;
D O I
10.1039/d1ra03268b
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new and sensitive potentiometric method has been developed and characterized for four novel sensors responsive to ondansetron hydrochloride. The potentiometric sensor method includes advancement of ondansetron hydrochloride sensors using a membrane comprised of molybdophosphoric acid (MPA) and ondansetron as an electro-active material in a polyvinylchloride (PVC) matrix membrane plasticized with di-butyl phthalate (DBPH), ortho-nitrophenyloctyl ether (O-NPOE), di-octyl phthalate (DOPH), or di-butyl phosphate (DBP). The validity of sensors in the present work has been examined, and steady and reproducible responses were obtained over the concentration ranges of 7.3 x 10(-5) to 1.0 x 10(-2), 6.6 x 10(-6) to 1.0 x 10(-2), 1.0 x 10(-5) to 1.0 x 10(-2), and 2.0 x 10(-5) to 1.0 x 10(-2) M for DBPH-, O-NPOE-, DOPH-, and DBP-ondansetron, respectively. The sensors revealed Nernstian gradients of 59.61 +/- 0.50, 57.71 +/- 0.23, 53.01 +/- 0.14, and 53.20 +/- 0.35 mV per decade individually with pH ranges of 2.5-5.5 in DBPH and 3.5-5.0 in O-NPOE electrodes, and 4.0-5.5 for both individual DOPH and DBP plasticized film-based sensors. The time responses for the sensors were 30, 32, 31, and 29 s for DBPH-, O-NPOE-, DOPH-, and DBP-ondansetron, respectively. The developed sensors also exhibited high selectivity towards ondansetron hydrochloride against different interfering species of inorganic particles with long-term stability of approximately 41, 36, 18, and multiple days for the DBPH, O-NPOE, DOPH, and DBP electrodes.
引用
收藏
页码:34820 / 34827
页数:8
相关论文
共 27 条
[1]  
Abass A. M., 2018, AL NAHRAIN J SCI, V21, P73
[2]   Bronsted acidity in deep eutectic solvents and ionic liquids [J].
Abbott, Andrew P. ;
Alabdullah, Sahar S. M. ;
Al-Murshedi, Azhar Y. M. ;
Ryder, Karl S. .
FARADAY DISCUSSIONS, 2018, 206 :365-377
[3]  
Anilkumar A, 2016, ASIAN J PHARM, V10, P188
[4]  
[Anonymous], 2012, BRIT PHARM VERS 17
[5]  
Asad R., 2007, ANAL CHEM, V6, P43
[6]  
British Pharmacopoeia, 2003, HER MAJ, P2
[7]   Simultaneous Determination of Dexamethasone, Ondansetron, Granisetron, Tropisetron, and Azasetron in Infusion Samples by HPLC with DAD Detection [J].
Chen, Fu-chao ;
Wang, Lin-hai ;
Guo, Jun ;
Shi, Xiao-ya ;
Fang, Bao-xia .
JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2017, 2017
[8]   DETERMINATION OF ONDANSETRON IN PLASMA AND ITS PHARMACOKINETICS IN THE YOUNG AND ELDERLY [J].
COLTHUP, PV ;
FELGATE, CC ;
PALMER, JL ;
SCULLY, NL .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1991, 80 (09) :868-871
[9]   PVC MATRIX MEMBRANE ION-SELECTIVE ELECTRODES - CONSTRUCTION AND LABORATORY EXPERIMENTS [J].
CRAGGS, A ;
MOODY, GJ ;
THOMAS, JDR .
JOURNAL OF CHEMICAL EDUCATION, 1974, 51 (08) :541-544
[10]  
Dedania Z., 2009, ASIAN J RES CHEM, V2, P108