Enzyme Biosensors for Biomedical Applications: Strategies for Safeguarding Analytical Performances in Biological Fluids

被引:337
作者
Rocchitta, Gaia [1 ]
Spanu, Angela [1 ]
Babudieri, Sergio [1 ]
Latte, Gavinella [1 ]
Madeddu, Giordano [1 ]
Galleri, Grazia [1 ]
Nuvoli, Susanna [1 ]
Bagella, Paola [1 ]
Demartis, Maria Ilaria [1 ]
Fiore, Vito [1 ]
Manetti, Roberto [1 ]
Serra, Pier Andrea [1 ]
机构
[1] Univ Sassari, Sch Med, Dept Clin & Expt Med, Viale S Pietro 43-B, I-07100 Sassari, Italy
关键词
biosensor; biomedical applications; amperometry; biological fluids; interferents; REDUCED GRAPHENE OXIDE; AMPEROMETRIC BIOSENSOR; SOL-GEL; GOLD NANOPARTICLES; L-LACTATE; IMMOBILIZATION STRATEGIES; GLUCOSE-DEHYDROGENASE; ALCOHOL-DEHYDROGENASE; CARBON NANOTUBES; IN-VIVO;
D O I
10.3390/s16060780
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Enzyme-based chemical biosensors are based on biological recognition. In order to operate, the enzymes must be available to catalyze a specific biochemical reaction and be stable under the normal operating conditions of the biosensor. Design of biosensors is based on knowledge about the target analyte, as well as the complexity of the matrix in which the analyte has to be quantified. This article reviews the problems resulting from the interaction of enzyme-based amperometric biosensors with complex biological matrices containing the target analyte(s). One of the most challenging disadvantages of amperometric enzyme-based biosensor detection is signal reduction from fouling agents and interference from chemicals present in the sample matrix. This article, therefore, investigates the principles of functioning of enzymatic biosensors, their analytical performance over time and the strategies used to optimize their performance. Moreover, the composition of biological fluids as a function of their interaction with biosensing will be presented.
引用
收藏
页数:21
相关论文
共 159 条
[61]   Scaffold electrodes based on thioctic acid-capped gold nanoparticles coordinated Alcohol Dehydrogenase and Azure A films for high performance biosensor [J].
Gomez-Anquela, C. ;
Garcia-Mendiola, T. ;
Abad, Jose M. ;
Pita, M. ;
Pariente, F. ;
Lorenzo, E. .
BIOELECTROCHEMISTRY, 2015, 106 :335-342
[62]   Fabrication of an Amperometric Flow-Injection Microfluidic Biosensor Based on Laccase for In Situ Determination of Phenolic Compounds [J].
Gonzalez-Rivera, Juan C. ;
Osma, Johann F. .
BIOMED RESEARCH INTERNATIONAL, 2015, 2015
[63]   Enhancement of operational stability of an enzyme biosensor for glucose and sucrose using protein based stabilizing agents [J].
Gouda, MD ;
Kumar, MA ;
Thakur, MS ;
Karanth, NG .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) :503-507
[64]   Electrochemical biosensors -: Sensor principles and architectures [J].
Grieshaber, Dorothee ;
MacKenzie, Robert ;
Voeroes, Janos ;
Reimhult, Erik .
SENSORS, 2008, 8 (03) :1400-1458
[65]   NONINVASIVE BIOSENSORS IN CLINICAL ANALYSIS [J].
GUILBAULT, GG ;
PALLESCHI, G ;
LUBRANO, G .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (3-4) :379-392
[66]   Engineering PQQ-glucose dehydrogenase into an allosteric electrochemical Ca2+ sensor [J].
Guo, Zhong ;
Johnston, Wayne A. ;
Stein, Viktor ;
Kalimuthu, Palraj ;
Perez-Alcala, Siro ;
Bernhardt, Paul V. ;
Alexandrov, Kirill .
CHEMICAL COMMUNICATIONS, 2016, 52 (03) :485-488
[67]   Immobilization as a Strategy for Improving Enzyme Properties-Application to Oxidoreductases [J].
Guzik, Urszula ;
Hupert-Kocurek, Katarzyna ;
Wojcieszynska, Danuta .
MOLECULES, 2014, 19 (07) :8995-9018
[68]   Electrochemical Glucose Sensors-Developments Using Electrostatic Assembly and Carbon Nanotubes for Biosensor Construction [J].
Harper, Alice ;
Anderson, Mark R. .
SENSORS, 2010, 10 (09) :8248-8274
[69]   Recent Advances in Application of Biosensors in Tissue Engineering [J].
Hasan, Anwarul ;
Nurunnabi, Md ;
Morshed, Mahboob ;
Paul, Arghya ;
Polini, Alessandro ;
Kuila, Tapas ;
Al Hariri, Moustafa ;
Lee, Yong-kyu ;
Jaffa, Ayad A. .
BIOMED RESEARCH INTERNATIONAL, 2014, 2014
[70]   Electrochemical lactate biosensor based upon chitosan/carbon nanotubes modified screen-printed graphite electrodes for the determination of lactate in embryonic cell cultures [J].
Hernandez-Ibanez, Naiara ;
Garcia-Cruz, Leticia ;
Montiel, Vicente ;
Foster, Christopher W. ;
Banks, Craig E. ;
Iniesta, Jesus .
BIOSENSORS & BIOELECTRONICS, 2016, 77 :1168-1174