Enzyme Biosensors for Biomedical Applications: Strategies for Safeguarding Analytical Performances in Biological Fluids

被引:332
作者
Rocchitta, Gaia [1 ]
Spanu, Angela [1 ]
Babudieri, Sergio [1 ]
Latte, Gavinella [1 ]
Madeddu, Giordano [1 ]
Galleri, Grazia [1 ]
Nuvoli, Susanna [1 ]
Bagella, Paola [1 ]
Demartis, Maria Ilaria [1 ]
Fiore, Vito [1 ]
Manetti, Roberto [1 ]
Serra, Pier Andrea [1 ]
机构
[1] Univ Sassari, Sch Med, Dept Clin & Expt Med, Viale S Pietro 43-B, I-07100 Sassari, Italy
来源
SENSORS | 2016年 / 16卷 / 06期
关键词
biosensor; biomedical applications; amperometry; biological fluids; interferents; REDUCED GRAPHENE OXIDE; AMPEROMETRIC BIOSENSOR; SOL-GEL; GOLD NANOPARTICLES; L-LACTATE; IMMOBILIZATION STRATEGIES; GLUCOSE-DEHYDROGENASE; ALCOHOL-DEHYDROGENASE; CARBON NANOTUBES; IN-VIVO;
D O I
10.3390/s16060780
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Enzyme-based chemical biosensors are based on biological recognition. In order to operate, the enzymes must be available to catalyze a specific biochemical reaction and be stable under the normal operating conditions of the biosensor. Design of biosensors is based on knowledge about the target analyte, as well as the complexity of the matrix in which the analyte has to be quantified. This article reviews the problems resulting from the interaction of enzyme-based amperometric biosensors with complex biological matrices containing the target analyte(s). One of the most challenging disadvantages of amperometric enzyme-based biosensor detection is signal reduction from fouling agents and interference from chemicals present in the sample matrix. This article, therefore, investigates the principles of functioning of enzymatic biosensors, their analytical performance over time and the strategies used to optimize their performance. Moreover, the composition of biological fluids as a function of their interaction with biosensing will be presented.
引用
收藏
页数:21
相关论文
共 159 条
[91]   Continuous and Simultaneous Electrochemical Measurements of Glucose, Lactate, and Ascorbate in Rat Brain Following Brain Ischemia [J].
Lin, Yuqing ;
Yu, Ping ;
Hao, Jie ;
Wang, Yuexiang ;
Ohsaka, Takeo ;
Mao, Lanqun .
ANALYTICAL CHEMISTRY, 2014, 86 (08) :3895-3901
[92]  
Liou G.Y., 2010, FREE RADIC RES
[93]   An Amperometric Biosensor Based on Ascorbate Oxidase Immobilized in Poly(3,4-ethylenedioxythiophene)/Multi-Walled Carbon Nanotubes Composite Films for the Determination of L-Ascorbic Acid [J].
Liu, Ming ;
Wen, Yangping ;
Xu, Jingkun ;
He, Haohua ;
Li, Dong ;
Yue, Ruirui ;
Liu, Guodong .
ANALYTICAL SCIENCES, 2011, 27 (05) :477-482
[94]   An intimately bonded titanate nanotube-polyaniline-gold nanoparticle ternary composite as a scaffold for electrochemical enzyme biosensors [J].
Liu, Xiaoqiang ;
Zhu, Jie ;
Huo, Xiaohe ;
Yan, Rui ;
Wong, Danny K. Y. .
ANALYTICA CHIMICA ACTA, 2016, 911 :59-68
[95]   Encapsulation of biomolecules in silica gels [J].
Livage, J ;
Coradin, T ;
Roux, C .
JOURNAL OF PHYSICS-CONDENSED MATTER, 2001, 13 (33) :R673-R691
[96]  
Lowe R.S., 2007, HDB BIOSENSORS BIOCH
[97]  
Madhavi V, 2009, BIORESOURCES, V4, P1694
[98]   Emerging roles of mitochondrial proteases in neurodegeneration [J].
Martinelli, Paola ;
Rugarli, Elena I. .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOENERGETICS, 2010, 1797 (01) :1-10
[99]   Oxygen tolerance of an implantable polymer/enzyme composite glutamate biosensor displaying polycation-enhanced substrate sensitivity [J].
McMahon, Colm P. ;
Rocchitta, Gaia ;
Kirwan, Sarah M. ;
Killoran, Sarah J. ;
Serra, Pier A. ;
Lowry, John P. ;
O'Neill, Robert D. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (07) :1466-1473
[100]   Control of the oxygen dependence of an implantable polymer/enzyme composite biosensor for glutamate [J].
McMahon, CP ;
Rocchitta, G ;
Serra, PA ;
Kirwan, SM ;
Lowry, JP ;
O'Neill, RD .
ANALYTICAL CHEMISTRY, 2006, 78 (07) :2352-2359