Enzyme Biosensors for Biomedical Applications: Strategies for Safeguarding Analytical Performances in Biological Fluids

被引:317
作者
Rocchitta, Gaia [1 ]
Spanu, Angela [1 ]
Babudieri, Sergio [1 ]
Latte, Gavinella [1 ]
Madeddu, Giordano [1 ]
Galleri, Grazia [1 ]
Nuvoli, Susanna [1 ]
Bagella, Paola [1 ]
Demartis, Maria Ilaria [1 ]
Fiore, Vito [1 ]
Manetti, Roberto [1 ]
Serra, Pier Andrea [1 ]
机构
[1] Univ Sassari, Sch Med, Dept Clin & Expt Med, Viale S Pietro 43-B, I-07100 Sassari, Italy
来源
SENSORS | 2016年 / 16卷 / 06期
关键词
biosensor; biomedical applications; amperometry; biological fluids; interferents; REDUCED GRAPHENE OXIDE; AMPEROMETRIC BIOSENSOR; SOL-GEL; GOLD NANOPARTICLES; L-LACTATE; IMMOBILIZATION STRATEGIES; GLUCOSE-DEHYDROGENASE; ALCOHOL-DEHYDROGENASE; CARBON NANOTUBES; IN-VIVO;
D O I
10.3390/s16060780
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Enzyme-based chemical biosensors are based on biological recognition. In order to operate, the enzymes must be available to catalyze a specific biochemical reaction and be stable under the normal operating conditions of the biosensor. Design of biosensors is based on knowledge about the target analyte, as well as the complexity of the matrix in which the analyte has to be quantified. This article reviews the problems resulting from the interaction of enzyme-based amperometric biosensors with complex biological matrices containing the target analyte(s). One of the most challenging disadvantages of amperometric enzyme-based biosensor detection is signal reduction from fouling agents and interference from chemicals present in the sample matrix. This article, therefore, investigates the principles of functioning of enzymatic biosensors, their analytical performance over time and the strategies used to optimize their performance. Moreover, the composition of biological fluids as a function of their interaction with biosensing will be presented.
引用
收藏
页数:21
相关论文
共 159 条
  • [1] Preparation of artificial hyper-hydrophilic micro-environments (polymeric salts) surrounding enzyme molecules -: New enzyme derivatives to be used in any reaction medium
    Abian, O
    Wilson, L
    Mateo, C
    Fernández-Lorente, G
    Palomo, JM
    Fernández-Lafuente, R
    Guisán, JM
    Re, D
    Tam, A
    Daminatti, M
    [J]. JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2002, 19 : 295 - 303
  • [2] Toward a human blood serum proteome - Analysis by multidimensional separation coupled with mass spectrometry
    Adkins, JN
    Varnum, SM
    Auberry, KJ
    Moore, RJ
    Angell, NH
    Smith, RD
    Springer, DL
    Pounds, JG
    [J]. MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (12) : 947 - 955
  • [3] Aggarwal V., 2016, ANAL BIOCH
  • [4] Monovalent cation-induced conformational change in glucose oxidase leading to stabilization of the enzyme
    Ahmad, A
    Akhtar, MS
    Bhakuni, V
    [J]. BIOCHEMISTRY, 2001, 40 (07) : 1945 - 1955
  • [5] Protective membranes at electrochemical biosensors
    Ambrozy, Anton
    Hlavata, Lenka
    Labuda, Jan
    [J]. ACTA CHIMICA SLOVACA, 2013, 6 (01): : 35 - 41
  • [6] Twenty years research in cholinesterase biosensors: From basic research to practical applications
    Andreescu, S
    Marty, JL
    [J]. BIOMOLECULAR ENGINEERING, 2006, 23 (01): : 1 - 15
  • [7] Characterization of Lactate Sensors Based on Lactate Oxidase and Palladium Benzoporphyrin Immobilized in Hydrogels
    Andrus, Liam P.
    Unruh, Rachel
    Wisniewski, Natalie A.
    McShane, Michael J.
    [J]. BIOSENSORS-BASEL, 2015, 5 (03): : 398 - 416
  • [8] Recent advances in cholesterol biosensor
    Arya, Sunil K.
    Datta, Monika
    Malhotra, Bansi D.
    [J]. BIOSENSORS & BIOELECTRONICS, 2008, 23 (07) : 1083 - 1100
  • [9] ENZYMES AND OTHER PROTEINS ENTRAPPED IN SOL-GEL MATERIALS
    AVNIR, D
    BRAUN, S
    LEV, O
    OTTOLENGHI, M
    [J]. CHEMISTRY OF MATERIALS, 1994, 6 (10) : 1605 - 1614
  • [10] Rapid amperometric detection of trace metals by inhibition of an ultrathin polypyrrole-based glucose biosensor
    Ayenimo, Joseph G.
    Adeloju, Samuel B.
    [J]. TALANTA, 2016, 148 : 502 - 510