A 5-YEAR RETROSPECTIVE ANALYSIS OF IONIZING RADIATION DOSE TO HYBRID OPERATING ROOM PERSONNEL IN SAUDI ARABIA

被引:3
作者
Almalki, Musaed [1 ]
Alashban, Yazeed [2 ]
Shubayr, Nasser [3 ,4 ]
机构
[1] Minist Hlth, Radiat Protect Program, Riyadh 12211, Saudi Arabia
[2] King Saud Univ, Coll Appl Med Sci, Dept Radiol Sci, Riyadh 11433, Saudi Arabia
[3] Jazan Univ, Coll Appl Med Sci, Dept Diagnost Radiog Technol, Jazan 45142, Saudi Arabia
[4] Jazan Univ, Med Res Ctr, Jazan 45142, Saudi Arabia
关键词
OCCUPATIONAL-EXPOSURE; SURGEON; FLUOROSCOPY; INJURIES;
D O I
10.1093/rpd/ncab110
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The annual average effective dose (ED) for operating room personnel (ORP) in Saudi Arabia was estimated from the period of 2015-2019 using thermoluminescent dosemeters. A retrospective analysis was conducted on annual EDs for 7530 ORP working across 52 hospitals. These workers were only exposed to radiation in the operating room. The annual average ED over the period of 5 years was found to be 0.59 mSv with no incidence of a dose above the annual dose limit of 20 mSv. The maximum annual ED reported was 15 mSv for an operating room worker in 2019. More than 88% of the workers received an annual ED of <1 mSv. The study concluded that the work environment in hybrid operating rooms across Saudi Arabia is safe. However, it is always recommended that workers take every protective measure when dealing with ionization radiation.
引用
收藏
页码:36 / 40
页数:5
相关论文
共 26 条
[1]   Radiation Exposure to the Surgeon During Percutaneous Endoscopic Lumbar Discectomy A Prospective Study [J].
Ahn, Yong ;
Kim, Chang-Ho ;
Lee, June Ho ;
Lee, Sang-Ho ;
Kim, Jin-Sung .
SPINE, 2013, 38 (07) :617-625
[2]  
Bushberg J. T., 1994, ESSENTIAL PHYS MED I, P55
[3]  
Clement Christopher, 2012, Ann ICRP, V41, P1, DOI 10.1016/j.icrp.2012.06.009
[4]   Reduction in Average Fluoroscopic Exposure Times for Interventional Spinal Procedures Through the Use of Pulsed and Low-Dose Image Settings [J].
Goodman, Bradly S. ;
Carnel, Charles T. ;
Mallempati, Srinivas ;
Agarwal, Pooja .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2011, 90 (11) :908-912
[5]   Assessment of the surgeon radiation exposure during a minimally invasive TLIF: Comparison between fluoroscopy and O-arm system [J].
Grelat, M. ;
Zairi, F. ;
Quidet, M. ;
Marinho, P. ;
Allaoui, M. ;
Assaker, R. .
NEUROCHIRURGIE, 2015, 61 (04) :255-259
[6]   Radiation exposure to the surgeon during fluoroscopically assisted percutaneous vertebroplasty - A prospective study [J].
Harstall, R ;
Heini, PF ;
Mini, RL ;
Orler, R .
SPINE, 2005, 30 (16) :1893-1898
[7]  
IAEA, 2011, IAEA SAFETY SERIES, V3, P1
[8]  
IAEA, 1996, IAEA SAF SER, V115, P1
[9]  
IAEA, 2018, IAEA SAFETY STANDARD, V7, P1
[10]   Optical fibre dosemeter systems for clinical applications based on radioluminescence and optically stimulated luminescence from Al2O3:C [J].
Marckmann, Carl Johan ;
Andersen, Claus E. ;
Aznar, Marianne C. ;
Botter-Jensen, Lars .
RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) :28-32