摘要
This work analyses the influence of the Internal Heat Exchan ger (IHX) on the energy performance of a vapor compression cycle associated with a freezing cabinet using different R404A low-GWP alternatives. Among them, the refrigerants R454C (GPW100=146), R455A (GPW100=146), R468A (GPW100=146), R290 (GPW100=5) and R1270 (GPW100=1.8) have been tested in a horizontal freezing cabinet maintaining a product target temperature of -20 degrees C at the heat rejection temperatures of 20, 30 and 40 degrees C. The results from tests show that the use of the IHX reduces energy consumption in all scenarios without significantly increasing the compressor's discharge temperature. For a test period of 16 h, the refrigerants that offer better reductions are R404A and R1270, followed by R455A, R290, R454C and R468A. The maximum energy saving is rated to 9.2% at the heat rejection temperature of 40 degrees C, demonstrating that the enhancement of the IHX is better as higher the heat rejection conditions are.
引用
收藏
页码:22 / 33
页数:12
相关论文
共 44 条
[31]   Experimental evaluation of the internal heat exchanger influence on a vapour compression plant energy efficiency working with R22, R134a and R407C [J].
Navarro-Esbrí, J ;
Cabello, R ;
Torrella, E .
ENERGY, 2005, 30 (05) :621-636
[32]   Experimental analysis of the internal heat exchanger influence on a vapour compression system performance working with R1234yf as a drop-in replacement for R134a [J].
Navarro-Esbri, Joaquin ;
Moles, Francisco ;
Barragan-Cervera, Angel .
APPLIED THERMAL ENGINEERING, 2013, 59 (1-2) :153-161
[33]   Experimental investigation of a CO2 trans-critical cycle with IHX for chiller application and its energetic and exergetic evaluation in warm climate [J].
Purohit, Nilesh ;
Gupta, Dileep Kumar ;
Dasgupta, Mani Sankar .
APPLIED THERMAL ENGINEERING, 2018, 136 :617-632
[34]   Performance improvement potentials of R1234yf mobile air conditioning system [J].
Qi, Zhaogang .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 58 :35-40
[35]   New positions for an internal heat exchanger in a CO2 supercritical refrigeration plant. Experimental analysis and energetic evaluation [J].
Sanchez, Daniel ;
Patino, Jorge ;
Llopis, Rodrigo ;
Cabello, Ramon ;
Torrella, Enrique ;
Vicente Fuentes, Fernando .
APPLIED THERMAL ENGINEERING, 2014, 63 (01) :129-139
[36]  
Stocker TF, 2014, CLIMATE CHANGE 2013: THE PHYSICAL SCIENCE BASIS, P1, DOI 10.1017/cbo9781107415324
[37]   On-site study of HCFC-22 substitution for HFC non-azeotropic blends (R417A, R422D) on a water chiller of a centralized HVAC system [J].
Torrella, E. ;
Cabello, R. ;
Sanchez, D. ;
Larumbe, J. A. ;
Llopis, R. .
ENERGY AND BUILDINGS, 2010, 42 (09) :1561-1566
[38]  
Torrella E., 2022, ENERGETIC EVALUATION
[39]  
UNEP, 2019, REPORT OF THE Refrigeration, Air Conditioning and Heat Pumps
[40]   Analysis of heat transfer characteristics of tube-in-tube internal heat exchangers for HFO-1234yf and HFC-134a refrigeration systems [J].
Wantha, Channarong .
APPLIED THERMAL ENGINEERING, 2019, 157