Energy impact of the Internal Heat Exchanger in a horizontal freezing cabinet. Experimental evaluation with the R404A low-GWP alternatives R454C, R455A, R468A, R290 and R1270

被引:16
作者
Cabello, Ramon
Sanchez, Daniel
Llopis, Rodrigo
Andreu-Nacher, Alejandro
Calleja-Anta, Daniel
机构
[1] Jaume I University, Dep. of Mechanical Engineering and Construction, Campus de Riu Sec s/n, Castellón,E-12071, Spain
关键词
R404a; R290; R1270; R454c; R455A; R468A; REFRIGERATION CYCLE; DROP-IN; WORKING; R134A; REPLACEMENT; R1234YF; R152A; PUMP; IHX;
D O I
10.1016/j.ijrefrig.2022.02.007
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work analyses the influence of the Internal Heat Exchan ger (IHX) on the energy performance of a vapor compression cycle associated with a freezing cabinet using different R404A low-GWP alternatives. Among them, the refrigerants R454C (GPW100=146), R455A (GPW100=146), R468A (GPW100=146), R290 (GPW100=5) and R1270 (GPW100=1.8) have been tested in a horizontal freezing cabinet maintaining a product target temperature of -20 degrees C at the heat rejection temperatures of 20, 30 and 40 degrees C. The results from tests show that the use of the IHX reduces energy consumption in all scenarios without significantly increasing the compressor's discharge temperature. For a test period of 16 h, the refrigerants that offer better reductions are R404A and R1270, followed by R455A, R290, R454C and R468A. The maximum energy saving is rated to 9.2% at the heat rejection temperature of 40 degrees C, demonstrating that the enhancement of the IHX is better as higher the heat rejection conditions are.
引用
收藏
页码:22 / 33
页数:12
相关论文
共 44 条
[11]   Energy evaluation of a low temperature commercial refrigeration plant working with the new low-GWP blend R468A as drop-in of R404A [J].
Cabello, Ramon ;
Sanchez, Daniel ;
Llopis, Rodrigo ;
Nebot-Andres, Laura ;
Calleja-Anta, Daniel .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 127 :1-11
[12]   Experimental investigation on the influence of internal heat exchanger in a transcritical CO2 heat pump water heater [J].
Cao, Feng ;
Ye, Zuliang ;
Wang, Yikai .
APPLIED THERMAL ENGINEERING, 2020, 168
[13]  
Coleman and Steele 2009, 2009, EXPT VALIDATION UNCE, V3rd
[14]  
Domanski P.A., 1995, 5606 NISTIR
[15]   EVALUATION OF SUCTION-LINE LIQUID-LINE HEAT-EXCHANGE IN THE REFRIGERATION CYCLE [J].
DOMANSKI, PA ;
DIDION, DA ;
DOYLE, JP .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1994, 17 (07) :487-493
[16]  
Emerson Climate Technologies, 1993, APPL ENG B
[17]  
Gosney W.B., 1982, PRINCIPLES REFRIGERA
[18]  
JCGM, 2008, Evaluation of measurement data-Guide to the expression of uncertainty in measurement
[19]   Comparison of transcritical CO2 refrigeration cycle with expander and throttling valve including/excluding internal heat exchanger: Exergy and energy points of view [J].
Joneydi Shariatzadeh, O. ;
Abolhassani, S. S. ;
Rahmani, M. ;
Nejad, M. Ziaee .
APPLIED THERMAL ENGINEERING, 2016, 93 :779-787
[20]   Performance evaluation of R-22 alternative mixtures in a breadboard heat pump with pure cross-flow condenser and counter-flow evaporator [J].
Kim, MH .
ENERGY, 2002, 27 (02) :167-181