Information regarding the long-term performance of stand-alone room air filters is limited. In this study, laboratory and field tests were carried out to determine the effectiveness and performance of room filters that are easily deployed in essentially any type of house. Tests were conducted in houses containing strong PM sources, specifically cigarette smokers. Using commercially available four-speed HEPA filter units, we tested flow rate, pressure drop, and power consumption as a function of fan speed and filter loading. Filters were then deployed in four single-family homes over a 2 month period. Between 15 and 40 cigarettes were smoked daily by several smokers in each home. Occupants were instructed to continuously operate the unit at one of the higher speeds. Periodically, we monitored filter usage, fan speed, particulate matter (PM) mass concentrations, PM number concentrations, volatile organic compound (VOC) levels, and other parameters with the filter fan operating and with filters both installed and removed. The filters decreased PM concentrations by 30-70%, depending on size fraction and occupant activities, and significantly reduced the half-life Of PM0.3-1.0. The half-life of 1-5 mu m particles, CO2 concentrations, and VOC concentrations, including 2,5-dimethyl furan (a tracer for environmental tobacco smoke), did not change, indicating that occupancy and Cigarette smoking intensity did not change over the monitoring periods. Occupants generally kept the filters operating at a moderate speed. Filter air flow rates decreased 7-14% with extended operation, largely due to the loading of prefilters. Air exchange rates, deposition loss rates, and clean air delivery rates were estimated from the field data. Continuous operation at an intermediate fan speed would incur a total annualized cost of $236. While acceptance of the filters was very high, occupants might benefit from instructions and reminders to clean the prefilter and to keep the unit on. We conclude that adequately sized room air filters can substantially lower PM concentrations in smoker's homes if air exchange rates are limited and that the filters can maintain their performance over extended periods.
引用
收藏
页码:7260 / 7268
页数:9
相关论文
共 52 条
[1]   Characterization of indoor particle sources: A study conducted in the metropolitan Boston area [J].
Abt, E ;
Suh, HH ;
Allen, G ;
Koutrakis, P .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2000, 108 (01) :35-44
[2]  
*AM NAT STAND I AS, 1987, AC11988 ANSIAHAM
[3]   EFFICACY OF AN AIR-CLEANING DEVICE EQUIPPED WITH A HIGH-EFFICIENCY PARTICULATE AIR FILTER IN HOUSE DUST MITE RESPIRATORY ALLERGY [J].
ANTONICELLI, L ;
BILO, MB ;
PUCCI, S ;
SCHOU, C ;
BONIFAZI, F .
ALLERGY, 1991, 46 (08) :594-600
[4]  
BALDWIN GT, 2003, GHESIS U MICHIGAN AN
[5]  
BOWSER D, 1999, P IND AIR 99 ED SCOT
[6]   Comparison of multiple environmental factors for asthmatic children in public housing [J].
Brugge, D ;
Vallarino, J ;
Ascolillo, L ;
Osgood, ND ;
Steinbach, S ;
Spengler, J .
INDOOR AIR, 2003, 13 (01) :18-27
[7]   Efficiency of a portable indoor air cleaner in removing pollens and fungal spores [J].
Cheng, YS ;
Lu, JC ;
Chen, TR .
AEROSOL SCIENCE AND TECHNOLOGY, 1998, 29 (02) :92-101
[8]  
CLAYTON CA, 1993, J EXPO ANAL ENV EPID, V3, P227
[9]   Tracers for assessing exposure to environmental tobacco smoke: What are they tracing? [J].
Daisey, JM .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1999, 107 :319-327
[10]   PERSONAL EXPOSURE TO RESPIRABLE PARTICULATES AND SULFATES [J].
DOCKERY, DW ;
SPENGLER, JD .
JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1981, 31 (02) :153-159