A novel LNG cryogenic energy utilization method for inlet air cooling to improve the performance of combined cycle

被引:59
作者
Zhang, Guoqiang [1 ]
Zheng, Jiongzhi [1 ]
Yang, Yongping [1 ]
Liu, Wenyi [1 ]
机构
[1] North China Elect Power Univ, Beijing Key Lab Emiss Surveillance & Control Ther, Natl Thermal Power Engn & Technol Res Ctr, Beijing 102206, Peoples R China
关键词
Inlet air cooling; CO2 working medium; LNG cryogenic energy utilization; Combine cycle; COLD ENERGY; POWER-PLANT; HEAT; GAS; TEMPERATURE; ENHANCEMENT; FUEL; HOT;
D O I
10.1016/j.apenergy.2016.07.035
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A novel liquefied natural gas (LNG) cryogenic energy utilization method for gas turbine inlet air cooling is proposed in this work. In this method, the temperature difference potential between LNG and cooling medium is utilized step by step. The novel cold production process consists of a CO2 Rankine cycle subsystem and a CO2 compression-refrigeration subsystem. A sensitivity analysis is performed to optimize the performance of the proposed novel cold production process. Results show that the cold energy output of the novel process is increased by about 36.5%, compared with that of the conventional cold production process via direct LNG evaporation. The off-design performance of the gas turbine combined cycle under different ambient conditions is also analyzed to identify the effect of the cold production process for inlet air cooling on a combined cycle power plant. The results indicated that by applying the novel cold production method for inlet air cooling, the combined cycle relative power output increment varies from 1.6% to 11.6%, when air humidity changes from 90% to 30%, compared with that without inlet air cooling. The combined cycle relative power and relative efficiency by the novel air cooling is by 0.50-2.47% and 0-0.11%, respectively, higher than that by conventional inlet air cooling. The novel cold production process is beneficial to the augmentation of cold energy output and combined cycle power output. However, there is no significant difference in the combined cycle efficiency between the novel and the conventional power systems. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:638 / 649
页数:12
相关论文
共 27 条
[21]   Performance enhancement of conventional combined cycle power plant by inlet air cooling, inter-cooling and LNG cold energy utilization [J].
Shi, Xiaojun ;
Agnew, Brian ;
Che, Defu ;
Gao, Jianmin .
APPLIED THERMAL ENGINEERING, 2010, 30 (14-15) :2003-2010
[22]   Thermodynamic analysis of a transcritical CO2 power cycle driven by solar energy with liquified natural gas as its heat sink [J].
Song, Yuhui ;
Wang, Jiangfeng ;
Dai, Yiping ;
Zhou, Enmin .
APPLIED ENERGY, 2012, 92 :194-203
[23]  
Srivastava G, 2004, PROCEEDINGS OF 2004 ASME POWER, P353
[24]   Performance analysis of a CCGT power plant integrated to a LNG regasification process [J].
Stradioto, Diogo Angelo ;
Seelig, Marina Fonseca ;
Schneider, Paulo Smith .
JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2015, 23 :112-117
[25]  
Wang JF, 2010, PROCEEDINGS OF THE ASME TURBO EXPO 2010, VOL 5, P77
[26]   A novel near-zero CO2 emission thermal cycle with LNG cryogenic exergy utilization [J].
Zhang, Na ;
Lior, Noam .
ENERGY, 2006, 31 (10-11) :1666-1679
[27]   Simulation of a novel single-column cryogenic air separation process using LNG cold energy [J].
Zheng Jieyu ;
Li Yanzhong ;
Li Guangpeng ;
Si Biao .
PROCEEDINGS OF THE 25TH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2014, 2015, 67 :116-122