摘要
To detect a stator winding fault caused by a short-circuited turn in a permanent magnet synchronous motor, a simple online fault detecting scheme is presented. The proposed scheme is based on the monitoring of the second-order harmonic components in the q-axis current through harmonic analysis. To verify the effectiveness of the proposed scheme, a test motor which allows an interturn short in the stator winding has been built, and the entire control system has been implemented using the DSP TMS320F28335.
引用
收藏
页码:2565 / 2568
页数:5
相关论文
共 8 条
[1]   Detection of stator short circuits in VSI-fed brushless DC motors using wavelet transform [J].
Awadallah, MA ;
Morcos, MM ;
Gopalakrishnan, S ;
Nehl, TW .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (01) :1-8
[2]   Online Model-Based Stator-Fault Detection and Identification in Induction Motors [J].
De Angelo, Cristian H. ;
Bossio, Guillermo R. ;
Giaccone, Santiago J. ;
Ines Valla, Maria ;
Solsona, Jorge A. ;
Garcia, Guillermo O. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (11) :4671-4680
[3]   Recent developments of induction motor drives fault diagnosis using AI techniques [J].
Filippetti, F ;
Franceschini, G ;
Tassoni, C ;
Vas, P .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2000, 47 (05) :994-1004
[4]   A Survey on Testing and Monitoring Methods for Stator Insulation Systems of Low-Voltage Induction Machines Focusing on Turn Insulation Problems [J].
Grubic, Stefan ;
Aller, Jose M. ;
Lu, Bin ;
Habetler, Thomas G. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (12) :4127-4136
[5]   Fault model and performance evaluation of an inverter-fed permanent magnet synchronous motor under winding shorted turn and inverter switch open [J].
Kim, K. -H. ;
Choi, D. -U. ;
Gu, B. -G. ;
Jung, I. -S. .
IET ELECTRIC POWER APPLICATIONS, 2010, 4 (04) :214-225
[6]   Stator-Interlaminar-Fault Detection Using an External-Flux-Density Sensor [J].
Romary, Raphael ;
Jelassi, Sana ;
Brudny, Jean Francois .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (01) :237-243
[7]   An unsupervised, on-line system for induction motor fault detection using stator current monitoring [J].
Schoen, RR ;
Lin, BK ;
Habetler, TG ;
Schlag, JH ;
Farag, S .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1995, 31 (06) :1280-1286
[8]   Current monitoring for detecting inter-turn short circuits in induction motors [J].
Stavrou, A ;
Sedding, HG ;
Penman, J .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2001, 16 (01) :32-37