Dosimetric comparison of RapidPlan and manually optimized plans in volumetric modulated arc therapy for prostate cancer

被引:80
|
作者
Kubo, Kazuki [1 ,2 ]
Monzen, Hajime [1 ]
Ishii, Kentaro [2 ]
Tamura, Mikoto [1 ]
Kawamorita, Ryu [2 ]
Sumida, Iori [3 ]
Mizuno, Hirokazu [3 ]
Nishimura, Yasumasa [4 ]
机构
[1] Kindai Univ, Grad Sch Med Sci, Dept Med Phys, 377-2 Ohno Higashi, Osaka 5898511, Japan
[2] Tane Gen Hosp, Dept Radiat Oncol, Nishi Ku, 1-12-21 Kujo Minami, Osaka 5500025, Japan
[3] Osaka Univ, Grad Sch Med, Dept Radiat Oncol, 2-2 Yamada Oka, Suita, Osaka 5650871, Japan
[4] Kindai Univ, Fac Med, Dept Radiat Oncol, 377-2 Ohno Higashi, Osaka 5898511, Japan
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2017年 / 44卷
基金
日本学术振兴会;
关键词
Knowledge-based planning; RapidPlan; VMAT; Prostate cancer; QUALITY-ASSURANCE; IMRT; VALIDATION; VMAT; RADIOTHERAPY; IMPACT; MODEL;
D O I
10.1016/j.ejmp.2017.06.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study evaluated whether RapidPlan based plans (RP plans) created by a single optimization, are usable in volumetric modulated arc therapy (VMAT) for patients with prostate cancer. Methods: We used 51 previously administered VMAT plans to train a RP model. Thirty RP plans were created by a single optimization without planner intervention during optimization. Differences between RP plans and clinical manual optimization (CMO) plans created by an experienced planner for the same patients were analyzed (Wilcoxon tests) in terms of homogeneity index (HI), conformation number (CN), D-95%, and D-2% to planning target volume (PTV), mean dose, V-50Gy, V-70Gy, V-75Gy, and V-78Gy to rectum and bladder, monitor unit (MU), and multi-leaf collimator (MLC) sequence complexity. Results: RP and CMO values for PTV D-95%, PTV D-2%, HI, and CN were significantly similar (p < 0.05 for all). RP mean dose, V-50Gy, and V-70Gy to rectum were superior or comparable to CMO values; RP V-75Gy and V-78Gy were higher than in CMO plans (p < 0.05). RP bladder dose-volume parameter values (except V-78Gy) were lower than in CMO plans (p < 0.05). MU values were RP: 730 +/- 55 MU and CMO: 580 +/- 37 MU (p < 0.05); and MLC sequence complexity scores were RP: 0.25 +/- 0.02 and CMO: 0.35 +/- 0.03 (p < 0.05). Conclusions: RP plans created by a single optimization were clinically acceptable in VMAT for patient with prostate cancer. Our simple model could reduce optimization time, independently of planner's skill and knowledge. (C) 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:199 / 204
页数:6
相关论文
共 50 条
  • [31] Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for pancreatic malignancies
    Ali, Arif N.
    Dhabaan, Anees H.
    Jarrio, Christie S.
    Siddiqi, Arsalan K.
    Landry, Jerome C.
    MEDICAL DOSIMETRY, 2012, 37 (03) : 271 - 275
  • [32] Dosimetric Comparison Study of Proton Therapy Using Line Scanning versus Passive Scattering and Volumetric Modulated Arc Therapy for Localized Prostate Cancer
    Takagi, Masaru
    Hasegawa, Yasuhiro
    Tateoka, Kunihiko
    Takada, Yu
    Hareyama, Masato
    CANCERS, 2024, 16 (02)
  • [33] The Dosimetric Performance of Volumetric Modulated Arc Therapy and Intensity Modulated Radiation Therapy in the Treatment of Locally Advanced Laryngeal Cancer
    Khater, Firas
    Attalla, Ehab
    Elshemey, Wael
    Mohammed, Haitham
    MIDDLE EAST JOURNAL OF CANCER, 2024, 15 (01) : 25 - 39
  • [34] Analytical dosimetric study of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for prostate cancer
    Samir, Fady
    Meaz, Talaat M.
    Hussiny, Fathi AEl
    Ahmed, Ahmed A.
    Mahmoud, Amr A.
    Refaat, Tamer
    Gawish, Ahmed
    Abouegylah, Mohamed
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2023, 149 (09) : 6239 - 6246
  • [35] Dosimetric analysis and comparison of volumetric-modulated arc therapy versus intensity-modulated radiation therapy for liver carcinoma
    Chiang, Bing-Hao
    Schnell, Erich
    Hibbitts, Kerry
    Herman, Terence
    Ahmad, Salahuddin
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 138 - 140
  • [36] Searching standard parameters for volumetric modulated arc therapy (VMAT) of prostate cancer
    Treutwein, Marius
    Hipp, Matthias
    Koelbl, Oliver
    Dobler, Barbara
    RADIATION ONCOLOGY, 2012, 7
  • [37] Analytical dosimetric study of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for prostate cancer
    Fady Samir
    Talaat M. Meaz
    Fathi AEl Hussiny
    Ahmed A. Ahmed
    Amr A. Mahmoud
    Tamer Refaat
    Ahmed Gawish
    Mohamed Abouegylah
    Journal of Cancer Research and Clinical Oncology, 2023, 149 : 6239 - 6246
  • [38] Effect of the Collimator Angle on Dosimetric Verification of Volumetric Modulated Arc Therapy
    Kim, Yong Ho
    Park, Ha Ryung
    Kim, Won Taek
    Kim, Dong Won
    Ki, Yongkan
    Lee, Juhye
    Bae, Jinsuk
    Park, Dahl
    Jeon, Hosang
    Nam, Ji Ho
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 243 - 247
  • [39] Impact of plan parameters on the dosimetric accuracy of volumetric modulated arc therapy
    Masi, Laura
    Doro, Raffaela
    Favuzza, Virginia
    Cipressi, Samantha
    Livi, Lorenzo
    MEDICAL PHYSICS, 2013, 40 (07)
  • [40] Evaluation of multiple institutions' models for knowledge-based planning of volumetric modulated arc therapy (VMAT) for prostate cancer
    Ueda, Yoshihiro
    Fukunaga, Jun-ichi
    Kamima, Tatsuya
    Adachi, Yumiko
    Nakamatsu, Kiyoshi
    Monzen, Hajime
    RADIATION ONCOLOGY, 2018, 13