Use of automated direct sample introduction with analyte protectants in the GC-MS analysis of pesticide residues

被引:76
作者
Cajka, T
Mastovská, K
Lehotay, SJ
Hajslová, J
机构
[1] Inst Chem Technol, Dept Food Chem & Anal, CR-16628 Prague, Czech Republic
[2] USDA ARS, Eastern Reg Res Ctr, Wyndmoor, PA 19038 USA
关键词
pesticide residue analysis; direct sample introduction; difficult matrix introduction; large volume injection; analyte protectants; gas chromatography-mass spectrometry; food analysis; baby food;
D O I
10.1002/jssc.200500050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Automated large-volume direct sample introduction, or difficult matrix introduction (DMI), was investigated in the determination of 44 pesticide residues possessing a wide range of physico-chemical properties (volatility, polarity, pK(a)) in fruit-based baby food by means of gas chromatography-mass spectrometry (GC-MS) with a quadrupole mass analyzer. DMI has advantages over traditional injection because large volumes (up to 30 mu L) of potentially dirty sample extracts can be injected into the GC-MS, but nonvolatile matrix components that would normally contaminate the inlet are removed after every injection. The extra matrix and glass surfaces involved in DMI, however, make the system more prone to the matrix-induced chromatographic enhancement effect, which adversely affects quantification of several pesticides. To overcome this problem, matrix-matched calibration standards and/or the use of analyte protectants were applied in the DMI approach, and the analysis of extracts was also compared before and after undergoing clean-up by dispersive solid-phase extraction. For best quantification, clean-up was still needed, and the combination of matrix-matching with analyte protectants gave the most reproducible results. Depending on the application, however, the addition of analyte protectants (a mixture of 3-ethoxy-1,2-propanediol, L-gulonic acid 3-lactone, and D-sorbitol) to sample extracts and calibration standards in solvent (non-matrix matched), gave satisfactory quantification for most of the 44 pesticides tested. The lowest calibration levels for 34 of the 44 pesticides were <= 10 ng/g, which meets the standard required by the European Union Baby Food Directive (2003/13/EC).
引用
收藏
页码:1048 / 1060
页数:13
相关论文
共 27 条
[1]   Analyses of pesticides and their metabolites in foods and drinks [J].
Ahmed, FE .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (11) :649-661
[2]   A direct sample introduction device for mass spectrometry studies and gas chromatography mass spectrometry analyses [J].
Amirav, A ;
Dagan, S .
EUROPEAN MASS SPECTROMETRY, 1997, 3 (02) :105-111
[3]   Evaluation of analyte protectants to improve gas chromatographic analysis of pesticides [J].
Anastassiades, M ;
Mastovská, K ;
Lehotay, SJ .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1015 (1-2) :163-184
[4]  
Anastassiades M, 2003, J AOAC INT, V86, P412
[5]   Recent advances in the application of mass spectrometry in food-related analysis [J].
Careri, M ;
Bianchi, F ;
Corradini, C .
JOURNAL OF CHROMATOGRAPHY A, 2002, 970 (1-2) :3-64
[6]   Trace-level determination of pesticides in food using difficult matrix introduction-gas chromatography-time-of-flight mass spectrometry [J].
de Koning, S ;
Lach, G ;
Linkerhägner, M ;
Löscher, R ;
Tablack, PH ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1008 (02) :247-252
[7]   Pesticide analysis with the pulsed-flame photometer detector and a direct sample introduction device [J].
Ding, HW ;
Amirav, A .
ANALYTICAL CHEMISTRY, 1997, 69 (07) :1426-1435
[8]   EXPLANATION OF THE MATRIX-INDUCED CHROMATOGRAPHIC RESPONSE ENHANCEMENT OF ORGANOPHOSPHORUS PESTICIDES DURING OPEN-TUBULAR COLUMN GAS-CHROMATOGRAPHY WITH SPLITLESS OR HOT ON-COLUMN INJECTION AND FLAME PHOTOMETRIC DETECTION [J].
ERNEY, DR ;
GILLESPIE, AM ;
GILVYDIS, DM ;
POOLE, CF .
JOURNAL OF CHROMATOGRAPHY, 1993, 638 (01) :57-63
[9]  
*EUR COMM, 2004, SANCO104762003 EUR C
[10]  
Godula M, 2001, J SEP SCI, V24, P355, DOI 10.1002/1615-9314(20010501)24:5&lt