Do Posttransplant Outcomes Differ in Heart Transplant Recipients Bridged With Continuous and Pulsatile Flow Left Ventricular Assist Devices?

被引:8
作者
Hong, Kimberly N.
Iribarne, Alexander
Yang, Jonathan
Ramlawi, Basel
Takayama, Hiroo
Naka, Yoshifumi
Russo, Mark J. [1 ]
机构
[1] Univ Chicago, Sect Cardiac & Thorac Surg, Med Ctr, Dept Surg, Chicago, IL 60637 USA
基金
美国国家卫生研究院;
关键词
MECHANICAL CIRCULATORY SUPPORT; NONPULSATILE;
D O I
10.1016/j.athoracsur.2011.02.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The purpose of this study was to compare posttransplantation morbidity and mortality in orthotopic heart transplant recipients bridged to transplant with (1) continuous-flow left ventricular assist device (LVAD), (2) pulsatile-flow LVAD, or (3) inotropic therapy only with no LVAD. Methods. The United Network for Organ Sharing provided deidentified patient-level data. All status 1 orthotopic heart transplant recipients (n = 7,744) 18 or more years of age and transplanted between January 1, 2001, and December 31, 2008, were included. Follow-up was available through June 18, 2009. Recipients were stratified into three groups: inotropes (n = 5,448, 70.4%), continuous-flow LVAD (CONT [n = 564, 7.3%]), and pulsatile-flow LVAD (PULS [n = 1,732, 22.4%]). The primary outcome measure was risk-adjusted posttransplant graft survival (PTGS) at 90 days. Secondary outcomes included risk-adjusted PTGS at 90 days to 1 year and 1 to 5 years. Results. Unadjusted PTGS was similar in all groups (p = 0.920). When compared with recipients bridged with inotropes, PTGS for patients bridged with an LVAD (CONT or PULS) did not differ in any follow-up period analyzed (<90 days, 90 days to 1 year, and 1 to 5 years). The PTGS in the CONT group (p = 0.021), but not in the PULS group (p = 0.244), improved significantly between the first half of the study period (2001 to 2004) and the second half (2005 to 2008). Conclusions. Compared with recipients bridged with inotropes, neither unadjusted nor adjusted PTGS differed for either the CONT group or the PULS group. Outcomes among the CONT group improved significantly from the first to the second half of the study period.
引用
收藏
页码:1899 / 1906
页数:8
相关论文
共 20 条
[1]  
Aaronson K, 2010, AM HEART ASS SCI SES
[2]   Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices [J].
Crow, Sheri ;
John, Ranjit ;
Boyle, Andrew ;
Shumway, Sara ;
Liao, Kenneth ;
Colvin-Adams, Monica ;
Toninato, Carol ;
Missov, Emil ;
Pritzker, Marc ;
Martin, Cindy ;
Garry, Daniel ;
Thomas, William ;
Joyce, Lyle .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (01) :208-215
[3]   Continuous Flow Rotary Left Ventricular Assist Device Mechanical Circulatory Support 2.0 [J].
Eisen, Howard J. ;
Hankins, Shelley R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (04) :322-324
[4]   Clinical outcome and bridge to transplant rate of left ventricular assist device recipient patients: comparison between continuous-flow and pulsatile-flow devices [J].
Garatti, Andrea ;
Bruschi, Giuseppe ;
Colombo, Tiziano ;
Russo, Claudio ;
Lanfranconi, Marco ;
Milazzo, Filippo ;
Frigerio, Maria ;
Vitali, Ettore .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 34 (02) :275-280
[5]   Assessing Technological Change in Cardiothoracic Surgery [J].
Iribarne, Alexander ;
Russo, Mark J. ;
Moskowitz, Alan J. ;
Ascheim, Deborah D. ;
Brown, Lawrence D. ;
Gelijns, Annetine C. .
SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2009, 21 (01) :28-34
[6]  
Jett GK, 1999, ASAIO J, V45, P119
[7]   Smooth muscle cell hypertrophy of renal cortex arteries with chronic continuous flow left ventricular assist [J].
Kihara, S ;
Litwak, KN ;
Nichols, L ;
Litwak, P ;
Kameneva, MV ;
Wu, ZJ ;
Kormos, RL ;
Griffith, BP .
ANNALS OF THORACIC SURGERY, 2003, 75 (01) :178-183
[8]   Does continuous flow left ventricular assist device technology have a positive impact on outcome pretransplant and posttransplant? [J].
Klotz, Stefan ;
Stypmann, Joerg ;
Welp, Henryk ;
Schmid, Christof ;
Drees, Gabriele ;
Rukosujew, Andreas ;
Scheld, Hans H. .
ANNALS OF THORACIC SURGERY, 2006, 82 (05) :1774-1778
[9]   Severely Impaired von Willebrand Factor-Dependent Platelet Aggregation in Patients With a Continuous-Flow Left Ventricular Assist Device (HeartMate II) [J].
Klovaite, Jolanta ;
Gustafsson, Finn ;
Mortensen, Svend A. ;
Sander, Kare ;
Nielsen, Lars B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (23) :2162-2167
[10]   Effects of long-term nonpulsatile left heart bypass on the mechanical properties of the aortic wall [J].
Nishimura, T ;
Tatsumi, E ;
Taenaka, Y ;
Nishinaka, T ;
Nakatani, T ;
Masuzawa, T ;
Nakata, M ;
Nakamura, M ;
Endo, S ;
Takano, H .
ASAIO JOURNAL, 1999, 45 (05) :455-459