Body weight-tailored contrast material injection protocol for 64-detector row computed tomography coronary angiography

被引:21
作者
Isogai, Tsuyoshi [1 ]
Jinzaki, Masahiro [1 ]
Tanami, Yutaka [1 ]
Kusuzaki, Hiroyuki [1 ]
Yamada, Minoru [2 ]
Kuribayashi, Sachio [1 ]
机构
[1] Keio Univ, Sch Med, Dept Diagnost Radiol, Shinjuku Ku, Tokyo 1608582, Japan
[2] Keio Univ, Sch Med, Cardiovasc Imaging Lab, Tokyo 1608582, Japan
关键词
Coronary CT angiography; Cardiac CT; Injection protocol; Contrast material; CT ANGIOGRAPHY; DIAGNOSTIC PERFORMANCE; IODINE CONCENTRATION; ARTERY STENOSIS; PATIENT WEIGHT; TEST-BOLUS; ENHANCEMENT; ATTENUATION; ACCURACY; DURATION;
D O I
10.1007/s11604-010-0514-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation. A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg(-1) with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg(-1) with 350 mg I/ml; protocol C, total of 0.7 ml kg(-1) with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values > 325 HU was compared on a pervessel and per-patient basis. The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P < 0.05). The attenuation value also signifi cantly exceeded 325 HU with protocol C (95% and 90%, respectively) more often than with protocol A or B on the per-patient analysis (P < 0.05). A total of at least 0.7 ml kg(-1) contrast material with 350 mg/ml iodine concentration is required to achieve optimal coronary CT attenuation (> 325 HU) with 64-detector CT when using an injection duration of 10 s.
引用
收藏
页码:33 / 38
页数:6
相关论文
共 22 条
[1]   Test-bolus versus bolus-tracking techniques for CT angiographic timing [J].
Bae, KT .
RADIOLOGY, 2005, 236 (01) :369-370
[2]   Contrast enhancement in cardiovascular MDCT: Effect of body weight, height, body surface area, body mass index, and obesity [J].
Bae, Kyongtae T. ;
Seeck, Brian A. ;
Hildebolt, Charles F. ;
Tao, Cheng ;
Zhu, Fang ;
Kanematsu, Masayuki ;
Woodard, Pamela K. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (03) :777-784
[3]   Effect of patient weight and scanning duration on contrast enhancement during pulmonary multidetector CT angiography [J].
Bae, Kyongtae T. ;
Tao, Cheng ;
Gurel, Safiye ;
Hong, Cheng ;
Zhu, Fang ;
Gebke, Todd A. ;
Milite, Margherita ;
Hildebolt, Charles F. .
RADIOLOGY, 2007, 242 (02) :582-589
[4]   Optimal contrast application for cardiac 4-detector-row computed tomography [J].
Becker, CR ;
Hong, C ;
Knez, A ;
Leber, A ;
Bruening, R ;
Schoepf, UJ ;
Reiser, MF .
INVESTIGATIVE RADIOLOGY, 2003, 38 (11) :690-694
[5]   Diagnostic Performance of 64-Multidetector Row Coronary Computed Tomographic Angiography for Evaluation of Coronary Artery Stenosis in Individuals Without Known Coronary Artery Disease [J].
Budoff, Matthew J. ;
Dowe, David ;
Jollis, James G. ;
Gitter, Michael ;
Sutherland, John ;
Halamert, Edward ;
Scherer, Markus ;
Bellinger, Raye ;
Martin, Arthur ;
Benton, Robert ;
Delago, Augustin ;
Min, James K. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (21) :1724-1732
[6]   Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: observations in an ex vivo model of coronary computed tomography angiography [J].
Cademartiri, F ;
Mollet, NR ;
Runza, G ;
Bruining, N ;
Hamers, R ;
Somers, P ;
Knaapen, M ;
Verheye, S ;
Midiri, M ;
Krestin, GP ;
de Feyter, PJ .
EUROPEAN RADIOLOGY, 2005, 15 (07) :1426-1431
[7]   Parameters affecting bolus geometry in CTA: A review [J].
Cademartiri, F ;
van der Lugt, A ;
Luccichenti, G ;
Pavone, P ;
Krestin, GP .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (04) :598-607
[8]   Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique [J].
Cademartiri, F ;
Nieman, K ;
van der Lugt, A ;
Raaijmakers, RH ;
Mollet, N ;
Pattynama, PMT ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2004, 233 (03) :817-823
[9]   Intravenous contrast material administration at helical 16-detector row CT coronary angiography: Effect of iodine concentration on vascular attenuation [J].
Cademartiri, F ;
Mollet, NR ;
van der Lugt, A ;
McFadden, EP ;
Stijnen, T ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2005, 236 (02) :661-665
[10]   High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography - Iopromide 370 versus iomeprol 400 [J].
Cademartiri, F ;
de Monye, C ;
Pugliese, F ;
Mollet, NR ;
Runza, G ;
van der Lugt, A ;
Midiri, M ;
de Feyter, PJ ;
Lagalla, R ;
Krestin, GP .
INVESTIGATIVE RADIOLOGY, 2006, 41 (03) :349-353