Determination of Formaldehyde in Water Samples by High-Performance Liquid Chromatography with Methyl Acetoacetate Derivatization

被引:12
|
作者
Yoshikawa, Kenji [1 ]
Oshima, Yusuke [1 ]
Inagaki, Ayaka [1 ]
Sakuragawa, Akio [1 ]
机构
[1] Nihon Univ, Coll Sci & Technol, Dept Mat & Appl Chem, Chiyoda Ku, 1-8-14 Kanda Surugadai, Tokyo 1018308, Japan
关键词
Formaldehyde; High-performance liquid chromatography; Hantzsch reaction; Derivatization; Methyl acetoacetate; Water samples; 2,4-DINITROPHENYLHYDRAZINE; ALDEHYDES; TOXICITY; REAGENT; RATS; MICE;
D O I
10.1007/s00128-018-2461-y
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A high-performance liquid chromatography method with methyl acetoacetate derivatization via the Hantzsch reaction was developed for the analysis of formaldehyde (HCHO) in several water samples. Under optimized conditions, HCHO was detected within 4min and was not affected by excessive derivatization reagents. The calibration curve constructed from the peak height of HCHO was linear, with a correlation coefficient of 0.9998. The relative standard deviation of the peak height from ten replicates was 0.29%. The detection and quantitative limits were 0.96 mu g/L and 3.16 mu g/L, respectively. A recovery test of HCHO was performed to compare the developed method with the official analysis method (DNPH method). The developed method was used to determine the HCHO levels in several water samples (tap water, river water, and waste water).
引用
收藏
页码:672 / 677
页数:6
相关论文
共 50 条
  • [41] Automated In-Injector Derivatization Combined with High-Performance Liquid Chromatography -Fluorescence Detection for the Determination of Semicarbazide in Fish and Bread Samples
    Wang, Yinan
    Chan, Wan
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2016, 64 (13) : 2802 - 2808
  • [42] Determination of carbohydrazide by high performance liquid chromatography with precolumn derivatization
    Wu, T
    Zhang, TL
    Sun, YH
    Zhang, JG
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (12) : 1639 - 1640
  • [43] Determination of trans-fatty acids in food samples based on the precolumn fluorescence derivatization by high performance liquid chromatography
    Wang, Fei-Hua
    Guo, Xiao-Feng
    Fan, Yao-Cheng
    Tang, Hai-Bin
    Liang, Wei
    Wang, Hong
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (08) : 1425 - 1433
  • [44] Determination of organophosphorus pesticides in environmental water samples by dispersive liquid–liquid microextraction with solidification of floating organic droplet followed by high-performance liquid chromatography
    Chunxia Wu
    Huimin Liu
    Weihua Liu
    Qiuhua Wu
    Chun Wang
    Zhi Wang
    Analytical and Bioanalytical Chemistry, 2010, 397 : 2543 - 2549
  • [45] High-performance liquid chromatography with postcolumn derivatization for simultaneous determination of organic peroxides and hydrogen peroxide
    Wang, KX
    Glaze, WH
    JOURNAL OF CHROMATOGRAPHY A, 1998, 822 (02) : 207 - 213
  • [46] Determination of aldehydes in tequila by high-performance liquid chromatography with 2,4-dinitrophenylhydrazine derivatization
    David Muñoz Rodríguez
    Katarzyna Wrobel
    Kazimierz Wrobel
    European Food Research and Technology, 2005, 221 : 798 - 802
  • [47] Determination of aldehydes in tequila by high-performance liquid chromatography with 2,4-dinitrophenylhydrazine derivatization
    Rodriquez, DM
    Wrobel, K
    Wrobel, K
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2005, 221 (06) : 798 - 802
  • [48] Determination of biogenic amines in wines by high-performance liquid chromatography with on-column fluorescence derivatization
    Busto, O
    Miracle, M
    Guasch, J
    Borrull, F
    JOURNAL OF CHROMATOGRAPHY A, 1997, 757 (1-2) : 311 - 318
  • [49] Spectrophotometric Determination of Formaldehyde in Seawater Samples after In-situ Derivatization and Dispersive Liquid-Liquid Microextraction
    Nassiri, Mahmoud
    Kaykhaii, Massoud
    Hashemi, Sayyed Hossein
    Sepahi, Massoud
    IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION, 2018, 37 (01): : 89 - 98
  • [50] Sensitive determination of melatonin by precolumn derivatization and reversed-phase high-performance liquid chromatography
    Iinuma, F
    Hamase, K
    Matsubayashi, S
    Takahashi, M
    Watanabe, M
    Zaitsu, K
    JOURNAL OF CHROMATOGRAPHY A, 1999, 835 (1-2) : 67 - 72